References
-
D.M. Crawford, B.W. Thomas, K. Bottcher, et al., Experimental verification of the flatness of response of a multi-
$BF_3$ counter neutron detection system, Nucl. Instrum. Methods 106 (1973) 311-315. https://doi.org/10.1016/0029-554X(73)90357-1 -
R.F. Barrett, J.R. Birkelund, H.H. Thies, Investigation of the flatness of response of a multi
$BF_3$ -counter neutron detection system, Nucl. Instrum. Methods 68 (1969) 277-283. https://doi.org/10.1016/0029-554X(69)90233-X - W.J. Lippold, A. Carnesale, R.P. Gardner, A Monte Carlo simulation of the surface-type neutron moisture gauge, Nucl. Eng. Des. 10 (1969) 373-380. https://doi.org/10.1016/0029-5493(69)90074-0
-
E.W. Lees, B.H. Patrick, E.M. Bowey, A high efficiency
$BF_3$ detector assembly for photofission and photoneutron studies, Nucl Instrum. Methods 171 (1980) 29-41. https://doi.org/10.1016/0029-554X(80)90006-3 - M.P. Dhairyawan, P.S. Nagarajan, G. Venkataraman, Response functions of spherically moderated neutron detectors, Nucl. Instrum. Methods 169 (1980) 115-120. https://doi.org/10.1016/0029-554X(80)90109-3
- H. Toyokawa, A. Uritani, C. Mori, et al., Neutron spectrometer with positionsensitive proportional counters, Nucl. Instrum. Methods Phys. Res. Sec. A 381 (1996) 481-487. https://doi.org/10.1016/S0168-9002(96)00755-3
- W.L. Dunn, J.K. Shultis, Monte Carlo methods for design and analysis of radiation detectors, Radiat. Phys. Chem. 78 (2009) 852-858. https://doi.org/10.1016/j.radphyschem.2009.04.030
- J. Saegusa, M. Yoshizawa, Y. Tanimura, et al., Evaluation of energy responses for neutron dose-equivalent meters made in Japan, Nucl. Instrum. Methods Phys. Res. Sec. A: Accelerators, Spectrometers, Detectors and Associated Equip. 516 (2004) 193-202.
- A. Haghighat, J.C. Wagner, Monte Carlo variance reduction with deterministic importance functions, Prog. Nucl. Energy 42 (2003) 25-53. https://doi.org/10.1016/S0149-1970(02)00002-1
- S.M. Mirza, M. Tufail, M. Rizwan Liaqat, Thermal neutron albedo and diffusion parameter measurements for monolithic and geometric voided reflectors, Radiat. Measurements 41 (2006) 89-94. https://doi.org/10.1016/j.radmeas.2005.03.005
- G.W. Neeley, D.L. Newell, S.L. Larson, et al., Reactivity Effects of Moderator and Reflector Materials on a Finite Plutonium System, SAIC, 2004, pp. 1322-1324, 2001 Rev. I, US NRC-Public Documents.
- M. Yamashita, L.D. Stephens, A.R. Smith, H.W. Patterson, Detector efficiency of bare and moderate BF3-gas-filled proportional counters for isotropic neutron fluxes, J. Nucl. Sci. Technol. 3 (8) (1966) 343-353. https://doi.org/10.1080/18811248.1966.9732339
- M.H. Kalos, P.A. Whitlock, Monte Carlo Methods, vol. 1, WILEY-VCH Verlag GmbH & Co., 1986.
Cited by
- A HYBRID MONTE-CARLO-DETERMINISTIC METHOD FOR AP1000 EX-CORE DETECTOR RESPONSE SIMULATION vol.247, pp.None, 2018, https://doi.org/10.1051/epjconf/202124705003