반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera

  • 반영각 (연세의료원 세브란스병원, 핵의학과) ;
  • 김동희 (연세의료원 세브란스병원, 핵의학과) ;
  • 최용훈 (연세의료원 세브란스병원, 핵의학과) ;
  • 강천구 (연세의료원 세브란스병원, 핵의학과) ;
  • 김재삼 (연세의료원 세브란스병원, 핵의학과)
  • Bahn, Young-Kag (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Dong-Heui (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Choi, Yong-Hoon (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kang, Chun-Koo (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System) ;
  • Kim, Jae-Sam (Department of Nuclear Medicine, Severance Hospital, Yonsei University Health System)
  • 투고 : 2018.10.01
  • 심사 : 2018.10.11
  • 발행 : 2018.10.31

초록

본 연구는 반도체 심근 전용 감마카메라를 이용하여 단시간에 검사가 가능한 이중 동위원소 심근 관류 동시스캔에 대해 임상적으로 연구 해보고자 한다. 심장 전용 감마카메라를 사용하여 Rest/Stress $^{99m}TC$-sestaMIBI 당일 심근관류 스캔과 Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ 이중 동위원소 심근 관류 동시 스캔을 같이 검사한 86명의 환자 중 검사 결과가 동일하고 임상적으로 심장질환의 변화가 없는 환자 36명을 대상으로 분석 했다. 두 검사의 영상의 상관성을 확인하기 위해 QPS 프로그램을 이용하여 정량적 값을 통계적으로 분석 했다. Rest/Stress $^{99m}TC$-sestaMIBI 당일 심근관류 스캔과 $^{99m}TC$-sesta MIBI/Stress $^{201}Tl$ 이중 동위원소 심근 관류 동시 스캔을 summed score에서 상관도를 분석했다. RSS의 $R^2$ 값은 0.91로 나왔고, SSS의 $R^2$ 값은 0.71로 나왔다. $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ 이중 동위원소 동시 검사는 기존 당일 검사와 상관성을 확인했다. $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ 이중 동위원소 동시 검사는 검사시간이 약 30분만에 완료가 가능하다. 응급환자나 고령의 환자 등 짧은 검사시간이 필요한 환자에게 임상적으로 도움이 될 것으로 사료된다.

Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

키워드

참고문헌

  1. Laetitia I, Sylvain P, Philippe R. F, et al. Compared Performance of High-Sensitivity Cameras Dedicated to Myocardial Perfusion SPECT: A Comprehensive Analysis of Phantom and Human Images. J Nucl Med 2012; 53:1897-1903 https://doi.org/10.2967/jnumed.112.107417
  2. Schillaci O, Danieli R. Dedicated cardiac cameras: a new option for nuclear myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2010;37:1706-1709. https://doi.org/10.1007/s00259-010-1526-x
  3. Mouden M, Timmer JR, Ottervanger JP, et al. Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose. Eur J Nucl Med Mol Imaging. 2012;39:1048-1055. https://doi.org/10.1007/s00259-012-2086-z
  4. Duvall WL, Croft LB, Ginsberg ES, et al. Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera. J Nucl Cardiol. 2011;18:847-857. https://doi.org/10.1007/s12350-011-9379-7
  5. Songy B, Guernou M, Lussato D, et al. Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera. Nucl Med Commun. 2012;33:464-469. https://doi.org/10.1097/MNM.0b013e3283504543
  6. Rajaram R, Bhattacharya M, Ding X, et al. Tomographic performance characteristics of the IQSPECT system. IEEE Nucl Sci Symp Conf Rec. 2011; 2451-2456.
  7. Erlandsson K, Kacperski K, Van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys Med Biol. 2009;54:2635-2649. https://doi.org/10.1088/0031-9155/54/9/003
  8. Bocher M, Blevis IM, Tsukerman L, Shrem Y, Kovalski G, Volokh L. A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur J Nucl Med Mol Imaging. 2010;37: 1887-1902. https://doi.org/10.1007/s00259-010-1488-z
  9. Buechel RR, Pazhenkottil AP, Herzog BA, et al. Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinctelluride detector gamma camera. Eur J Nucl Med Mol Imaging. 2010;37: 1903-1908. https://doi.org/10.1007/s00259-010-1480-7
  10. Pazhenkottil AP, Buechel RR, Herzog BA, et al. Ultrafast assessment of left ventricular dyssynchrony from nuclear myocardial perfusion imaging on a new high-speed gamma camera. Eur J Nucl Med Mol Imaging. 2010;37:2086-2092. https://doi.org/10.1007/s00259-010-1507-0
  11. Simona B, Krzysztof K, Sharon H, et al. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol Imaging. Published online: 11 April 2010.
  12. Ayano Makita, Naoya Matsumoto, Yasuyuki Suzuki, et. al. Clinical Feasibility of Simultaneous Acquisition Rest $^{99m}Tc$/Stress 201Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera. Circulation Journal. Published online: 18 January 2016.