DOI QR코드

DOI QR Code

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo (Department of Internal Medicine, Presbyterian Medical Center) ;
  • Lee, Seung Hyun (Department of Internal Medicine, Chonnam National University Medical School) ;
  • Myung, Dae Seong (Department of Internal Medicine, Chonnam National University Medical School) ;
  • Lee, Wan Sik (Department of Internal Medicine, Chonnam National University Medical School) ;
  • Joo, Young Eun (Department of Internal Medicine, Chonnam National University Medical School) ;
  • Jung, Mi Ran (Department of Surgery, Chonnam National University Medical School) ;
  • Ryu, Seong Yeob (Department of Surgery, Chonnam National University Medical School) ;
  • Park, Young Kyu (Department of Surgery, Chonnam National University Medical School) ;
  • Cho, Sung Bum (Department of Internal Medicine, Chonnam National University Medical School)
  • Received : 2017.12.22
  • Accepted : 2018.01.29
  • Published : 2018.03.31

Abstract

Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

Keywords

References

  1. Griffin SM, Lamb PJ, Dresner SM, Richardson DL, Hayes N. Diagnosis and management of a mediastinal leak following radical oesophagectomy. Br J Surg 2001;88:1346-1351. https://doi.org/10.1046/j.0007-1323.2001.01918.x
  2. Pross M, Manger T, Reinheckel T, Mirow L, Kunz D, Lippert H. Endoscopic treatment of clinically symptomatic leaks of thoracic esophageal anastomoses. Gastrointest Endosc 2000;51:73-76. https://doi.org/10.1016/S0016-5107(00)70391-9
  3. Alanezi K, Urschel JD. Mortality secondary to esophageal anastomotic leak. Ann Thorac Cardiovasc Surg 2004;10:71-75.
  4. DaVee T, Irani S, Leggett CL, Berzosa Corella M, Grooteman KV, Wong Kee Song LM, et al. Stent-instent technique for removal of embedded partially covered self-expanding metal stents. Surg Endosc 2016;30:2332-2341.
  5. Langer FB, Schoppmann SF, Prager G, Riegler FM, Zacherl J. Solving the problem of difficult stent removal due to tissue ingrowth in partially uncovered esophageal self-expanding metal stents. Ann Thorac Surg 2010;89:1691-1692. https://doi.org/10.1016/j.athoracsur.2009.07.066
  6. Shim CS, Cho YD, Moon JH, Kim JO, Cho JY, Kim YS, et al. Fixation of a modified covered esophageal stent: its clinical usefulness for preventing stent migration. Endoscopy 2001;33:843-848. https://doi.org/10.1055/s-2001-17326
  7. Rutegard M, Lagergren P, Rouvelas I, Lagergren J. Intrathoracic anastomotic leakage and mortality after esophageal cancer resection: a population-based study. Ann Surg Oncol 2012;19:99-103. https://doi.org/10.1245/s10434-011-1926-6
  8. Swinnen J, Eisendrath P, Rigaux J, Kahegeshe L, Lemmers A, Le Moine O, et al. Self-expandable metal stents for the treatment of benign upper GI leaks and perforations. Gastrointest Endosc 2011;73:890-899. https://doi.org/10.1016/j.gie.2010.12.019
  9. Suzuki T, Siddiqui A, Taylor LJ, Cox K, Hasan RA, Laique SN, et al. Clinical outcomes, efficacy, and adverse events in patients undergoing esophageal stent placement for benign indications: a large multicenter study. J Clin Gastroenterol 2016;50:373-378.
  10. Shim CN, Kim HI, Hyung WJ, Noh SH, Song MK, Kang DR, et al. Self-expanding metal stents or nonstent endoscopic therapy: which is better for anastomotic leaks after total gastrectomy? Surg Endosc 2014;28:833-840. https://doi.org/10.1007/s00464-013-3228-5
  11. Choi CW, Kang DH, Kim HW, Park SB, Kim SJ, Hwang SH, et al. Full covered self-expandable metal stents for the treatment of anastomotic leak using a silk thread. Medicine (Baltimore) 2017;96:e7439. https://doi.org/10.1097/MD.0000000000007439
  12. van Boeckel PG, Sijbring A, Vleggaar FP, Siersema PD. Systematic review: temporary stent placement for benign rupture or anastomotic leak of the oesophagus. Aliment Pharmacol Ther 2011;33:1292-1301. https://doi.org/10.1111/j.1365-2036.2011.04663.x
  13. Salminen P, Gullichsen R, Laine S. Use of self-expandable metal stents for the treatment of esophageal perforations and anastomotic leaks. Surg Endosc 2009;23:1526-1530. https://doi.org/10.1007/s00464-009-0432-4
  14. van Halsema EE, Wong Kee Song LM, Baron TH, Siersema PD, Vleggaar FP, Ginsberg GG, et al. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases. Gastrointest Endosc 2013;77:18-28. https://doi.org/10.1016/j.gie.2012.09.001
  15. Wadhwa RP, Kozarek RA, France RE, Brandabur JJ, Gluck M, Low DE, et al. Use of self-expandable metallic stents in benign GI diseases. Gastrointest Endosc 2003;58:207-212. https://doi.org/10.1067/mge.2003.343
  16. Chaput U, Heresbach D, Audureau E, Vanbiervliet G, Gaudric M, Bichard P, et al. Comparison of a standard fully covered stent with a super-thick silicone-covered stent for the treatment of refractory esophageal benign strictures: a prospective multicenter study. United European Gastroenterol J 2013;1:93-102. https://doi.org/10.1177/2050640613476501

Cited by

  1. Self-expanding metal stent in esophageal perforations and anastomotic leaks vol.39, pp.5, 2018, https://doi.org/10.1007/s12664-020-01078-z
  2. Effectiveness of a Novel Covered Stent without External Thread Fixation for Anastomotic Leakage after Total or Proximal Gastrectomy for Gastric Cancer vol.13, pp.15, 2021, https://doi.org/10.3390/cancers13153720