Figure 1. Results of aluminum ion concentration determination using EP method.
Figure 2. Aluminum test of test solution by color comparison with standard (1, 2, 5, 10, 20, 50 ppm) and control solutions.
Figure 3. Results of color change of test solution according to pH (3 ~ 9).
Figure 4. Change in solution color (A) and OD measurement (B) according to volume of test and standard solutions used in test
Figure 5. Comparison of color when test and standard solutions are added after 0 h or 4 h after mixing of the buffer solution and chrome azurol S.
References
- Al-Mallah MH, Sitek A, Moore SC, Di Carli M, Dorbala S. Assessment of myocardial perfusion and function with PET and PET/CT. J Nucl Cardiol. 2010;17:498-513. https://doi.org/10.1007/s12350-010-9223-5
- Hutchins GD, Schwaiger M, Rosenspire KC, Krivokapich J, Schelbert H, Kuhl DE. Noninvasive Quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. J Am Coll Cardiol. 1990;15:1032-1042. https://doi.org/10.1016/0735-1097(90)90237-J
-
Rust TC, DiBella EV, McGann CJ, Christian PE, Hoffman JM, Kadrmas DJ. Rapid dual-injection single-scan
$^{13}N$ -ammonia PET for quantification of rest and stress myocardial blood flows. Phys Med Biol. 2006;51:5347-5362. https://doi.org/10.1088/0031-9155/51/20/018 -
Parker JA, Beller GA, Hoop B, Holman BL, Smith TW. Assessment of regional myocardial blood flow and regional fractional oxygen extraction in dogs, using
$^{15}O$ -water and$^{15}O$ -hemoglobin. Circ Res. 1978;42:511-518. https://doi.org/10.1161/01.RES.42.4.511 - Selwyn AP, Allan RM, L'Abbate A, Horlock P, Camici P, Clark J, O'Brien HA, Grant PM. Relation between regional myocardial uptake of rubidium-82 and perfusion Absolute reduction of cation uptake in ischemia. Am J Cardiol. 1982;50:112-121. https://doi.org/10.1016/0002-9149(82)90016-9
- Bailey IK, Griffith LS, Rouleau J, Strauss W, Pitt B. Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease. Circulation. 1977;55:79-87. https://doi.org/10.1161/01.CIR.55.1.79
- Wackers FJ, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, Boucher CA, Picard M, Holman BL, Fridrich R, Inglese E, Delaloye B, Bischof-Delaloye A, Camin L, Mckusick K. Technetium-99m hexakis 2-methoxyisobutyl isonitrile human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med. 1989;30:301-311.
- Knuuti J, Kajander S, Maki M, Ukkonen H. Quantification of myocardial blood flow will reform the detection of CAD. J Nucl Cardiol. 2009;16:497-506. https://doi.org/10.1007/s12350-009-9101-1
-
Vaalburg W, Kamphuis JAA, Beerling-van der molen HD, Reiffers S, Rijskamp A, Woldring MG. An improved method for the cyclotron production of
$^{13}N$ -labelled ammonia. Int J Appl Radiat Isot. 1975;26:316-318. https://doi.org/10.1016/0020-708X(75)90169-6 - McLachlan DRC. Aluminium and the risk for alzheimer's disease. Environmetrics. 1995;6:233-275. https://doi.org/10.1002/env.3170060303
- Monteagudo FS, Cassidy MJ, Folb PI . Recent developments in aluminum toxicology. Med Toxicol Adverse Drug Exp. 1989;4:1-16.
- Jeffery EH, Abreo K, Burgess E, Cannata J, Greger JL. Systemic aluminum toxicity: Effects on bone, hematopoietic tissue, and kidney. J Toxicol Environ Health. 1996;48:649-665. https://doi.org/10.1080/009841096161122