References
- Kim DS, Rashsuren O, Kim EK. Conversion coefficients for the estimation of effective dose in cone-beam CT. Imaging Sci Dent 2014; 44: 21-9. https://doi.org/10.5624/isd.2014.44.1.21
- Ludlow JB, Timothy R, Walker C, Hunter R, Benavides E, Samuelson D, et al. Effective dose of dental CBCT - a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol 2015; 44: 20140197. https://doi.org/10.1259/dmfr.20140197
- Martin CJ. Effective dose: how should it be applied to medical exposures? Br J Radiol 2007; 80: 639-47. https://doi.org/10.1259/bjr/25922439
- Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A, et al. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 2012; 81: 267-71. https://doi.org/10.1016/j.ejrad.2010.11.028
- Al-Okshi A, Lindh C, Sale H, Gunnarsson M, Rohlin M. Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review. Br J Radiol 2015; 88: 20140658. https://doi.org/10.1259/bjr.20140658
- Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 106-14. https://doi.org/10.1016/j.tripleo.2008.03.018
- Koivisto J, Kiljunen T, Tapiovaara M, Wolff J, Kortesniemi M. Assessment of radiation exposure in dental cone-beam computerized tomography with the use of metal-oxide semiconductor field-effect transistor (MOSFET) dosimeters and Monte Carlo simulations. Oral Surg Oral Med Oral Pathol Oral Radiol 2012; 114: 393-400. https://doi.org/10.1016/j.oooo.2012.06.003
- Aps JK, Scott JM. Oblique lateral radiographs and bitewings; estimation of organ doses in head and neck region with Monte Carlo calculations. Dentomaxillofac Radiol 2014; 43: 20130419. https://doi.org/10.1259/dmfr.20130419
- Lee C, Lee SS, Kim JE, Huh KH, Yi WJ, Heo MS, et al. Comparison of dosimetry methods for panoramic radiography: thermoluminescent dosimeter measurement versus personal computer-based Monte Carlo method calculation. Oral Surg Oral Med Oral Pathol Oral Radiol 2016; 121: 322-9. https://doi.org/10.1016/j.oooo.2015.10.030
- Podnieks EC, Negus IS. Practical patient dosimetry for partial rotation cone beam CT. Br J Radiol 2012; 85: 161-7. https://doi.org/10.1259/bjr/18118287
- Vassileva J, Stoyanov D. Quality control and patient dosimetry in dental cone beam CT. Radiat Prot Dosimetry 2010; 139: 310-2. https://doi.org/10.1093/rpd/ncq011
- Bai M, Liu X, Liu B. Effective patient dose during neuroradiological C-arm CT procedures. Diagn Interv Radiol 2013; 19: 29-32.
- He W, Huda W, Magill D, Tavrides E, Yao H. Patient doses and projection angle in cone beam CT. Med Phys 2010; 37: 2359-68. https://doi.org/10.1118/1.3397458
- Khelassi-Toutaoui N, Berkani Y, Tsapaki V, Toutaoui AE, Merad A, Frahi-Amroun A, et al. Experimental evaluation of PCXMC and prepare codes used in conventional radiology. Radiat Prot Dosimetry 2008; 131: 374-8. https://doi.org/10.1093/rpd/ncn183
- Kawasaki T, Aoyama T, Yamauchi-Kawaura C, Fujii K, Koyama S. Organ dose and effective dose estimation in paediatric chest radiographic examinations by using pin silicon photodiode dosemeters. Radiat Prot Dosimetry 2013; 154: 314-9. https://doi.org/10.1093/rpd/ncs251
- Okano T, Matsuo A, Gotoh K, Yokoi M, Hirukawa A, Okumura S, et al. Comparison of absorbed and effective dose from two dental cone beam computed tomography scanners. Nihon Hoshasen Gijutsu Gakkai Zasshi 2012; 68: 216-25. https://doi.org/10.6009/jjrt.2012_JSRT_68.3.216
- Reeves TE, Mah P, McDavid WD. Deriving Hounsfield units using grey levels in cone beam CT: a clinical application. Dentomaxillofac Radiol 2012; 41: 500-8. https://doi.org/10.1259/dmfr/31640433
- The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 2007; 37: 1-332.
- Tapiovaara M, Siiskonen T. PCXMC, a Monte Carlo program for calculating patient doses in medical X-ray examinations. 2nd ed. Report STUK-A231. Helsinki: Finnish Centre for Radiation and Nuclear Safety Authority; 2008.
- Qu XM, Li G, Ludlow JB, Zhang ZY, Ma XC. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 770-6. https://doi.org/10.1016/j.tripleo.2010.06.013
Cited by
- A review of dental cone-beam CT dose conversion coefficients vol.50, pp.3, 2021, https://doi.org/10.1259/dmfr.20200225
- Thermoluminescent dosimetry of panoramic radiography vol.45, pp.1, 2018, https://doi.org/10.21851/obr.45.01.202103.22