DOI QR코드

DOI QR Code

Full-Scale Shaking Table Test and Analysis of Seismic Ceiling Systems

내진 천장시스템의 실규모 진동대 실험 및 해석

  • Received : 2018.01.24
  • Accepted : 2018.01.29
  • Published : 2018.03.15

Abstract

In the current research, a seismic ceiling system as one of non-structural elements in buildings has been developed by applying newly designed vertical hanger clips combined with M-bar channel clips. In order to evaluate the seismic performance of the developed system, full-scale shaking table tests of one story frame structure with the conventional ceiling system or the developed seismic ceiling system were performed with time-history responses under earthquake loads. The developed system was also evaluated by the time-history dynamic analysis. From seismic test and analysis, it was shown that the developed seismic ceiling system could give improved seismic performances to minimize displacements and damages of ceiling systems as well as enhance seismic safety of the ceiling system.

Keywords

References

  1. Korea Meteorological Administration, http://www.kma.go.kr
  2. Federal Emergency Management Agency, Reducing the Risks of Nonstructural Earthquake Damage - A Practical Guide, FEMA E-74 , Washington, D.C., pp.755, 2011
  3. Soroushian, S., Ryan, K. L., Maragakis, M., Sato, E., Sasaki, T., Okazaki, T., ... Alvarez D., "Seismic Response of Ceiling/Sprinkler Piping Nonstructural Systems in NEES TIPS/NEES Nonstructural/NIED Collaborative Tests on a Full Scale 5-Story Building", Structures Congress 2012, pp.1315-1326, 2012
  4. Wanitkorkul, A., & Filiatrault, A., "Influence of passive supplemental damping systems on structural and nonstructural seismic fragilities of a steel building", Engineering Structures, Vol.30, No.3, pp.675-682, 2008 https://doi.org/10.1016/j.engstruct.2007.05.013
  5. Nishiyama, I., Ito, H., Nishida, K., & Yang, I. S., "Damage to gymnasium ceiling at the geiyo earthquake and its countermeasures", AIJ Journal of Technology and Design, Vol.8, No.16, pp.367-372, 2002 https://doi.org/10.3130/aijt.8.367_2
  6. Federal Emergency Management Agency, Improvement of Nonlinear Static Seismic Analysis Procedures(FEMA-440), Washington, DC, pp.392, 2005
  7. Federal Emergency Management Agency, Prestandard and Commentary for the Seismic Rehabilitation of Buildings(FEMA-356), Washington, DC, pp.518, 2000
  8. Federal Emergency Management Agency, Nehrp Guidelines for the Seismic Rehabilitation of Buildings(FEMA-273), 1997
  9. Applied Technology Council, Seismic Evaluation and Retrofit of Concrete Buildings (ATC-40), State of California, Vol.1, pp.334, 1996
  10. MIDAS Information Technology CO. LTD, MIDAS-GEN User's Manual
  11. Seismic Simulation Test Center(SESTEC), Shaking Table Experiment for Development of Seismic Resistance Performance of Ceiling System, Report No. SESTEC-2017-R-066-0-Rev.0, Pusan, 2017
  12. Ministry of Education, "Design Standards for School Facilities Earthquake-Resistance", No.2009(13), Korea, pp.37, 2009