DOI QR코드

DOI QR Code

Study on Performance Evaluation of Concrete Using Electric Arc Furnace Oxidizing Slag Aggregate

전기로 산화슬래그 골재를 사용한 콘크리트의 성능 평가에 관한 연구

  • 임희섭 (한양대학교 건축시스템공학과) ;
  • 이한승 (한양대학교 ERICA 건축학부)
  • Received : 2017.04.27
  • Accepted : 2017.06.15
  • Published : 2017.07.01

Abstract

As the shortage of concrete aggregates is intensifying, the development of alternative resources is urgent. As the amount of steel slag increases year by year, attempts are being made to recycle slag into high-value-added products in order to develop an efficient resource recycling industry based on slag and to obtain economic benefits. However, the use of electric arc furnace oxidizing slag (EOS) as building materials is practically limited because it contains unstable materials. In this paper, physical properties of concrete were evaluated by using electric arc furnace slag aggregate. It has been produced with two levels of general strength area W / C 45% and high strength area W / C 30%. Fresh concrete has been tested in air content, flow and slump, unit weight. The properties of the cured concrete were investigated by compressive strength, bending strength and unit volume weight. As a result of this study, strength of concrete increased with increasing EOS aggregate mixture.

본 논문은 전기로 산화슬래그 골재를 사용하여 콘크리트를 제작하여 물리적 성능을 평가하였다. 실험은 전기로 산화슬래그 골재를 치환하여(잔골재-굵은골재) 0%-0%, 0%-100%, 50%-100%, 100%-100%으로 각 4수준으로 일반강도영역 W/C 45%와 고강도영역인 W/C 30%의 2수준으로 제작하여 진행하였다. 굳지 않은 콘크리트에서는 공기량, 플로우 및 슬럼프, 단위용적질량 실험을 진행하였으며, 경화 콘크리트에서는 압축강도 및 휨강도, 단위용적질량 실험을 통하여 물리적 특성을 검토하였다. 본 연구의 실험결과 전기로 산화슬래그의 혼입량이 증가함에 따라 콘크리트의 강도 증진 효과가 나타났으며, 이는 전기로 산화슬래그 골재 내에 ${\beta}-C2S$로 인하여 골재 내외부에서 강도 증진 효과를 발휘한 것으로 사료된다.

Keywords

References

  1. Cho B. S., Lee H. H., Yang S. K., Lee W. J., and Um T. S. (2009), Appraisal of Concrete Performance and Plan for Stable Use of EAF Oxidizing Slag as Fine Aggregate of Concrete, Journal of the Korea Concrete Institute, 21, 367-375. https://doi.org/10.4334/JKCI.2009.21.3.367
  2. Ha J. S., Shin J. H., Chung L., and Kim H. S. (2016), Performance Evaluation of Recycled Aggregate Concrete Made of Recycled Aggregate Modified by Carbonation, Journal of the korea concrete institute, 28, 445-454. https://doi.org/10.4334/JKCI.2016.28.4.445
  3. Kim S. M., Park J. W., Lee H. H., and Kim K. H. (2008), Study on Utilization of Electric Arc Furnace Oxidizing Slag as Fine Aggregates for Cement Concrete, Korea Society of Civil Engineers, 28, 407-415.
  4. Kim, J. M., and Park, H. I. (2012), Evaluation on Volume Stability of the Electric Arc Furnace Oxidizing Slag Aggregate by Hydro Thermal Condition, Journal of Material Cycles and Waste Management, 29, 551-560.
  5. Kuo, W. T., and Shu, C. Y. (2014), Application of High-temperature Rapid Catalytic Technology to Forecast the Volumetric Stability Behavior of Containing Steel Slag Mixtures, Construction and Building Materials, 50, 463-470. https://doi.org/10.1016/j.conbuildmat.2013.09.030
  6. Lee S. H., Lim D. S., Lee S. H., and Lee J. H. (2013), Mechanism of Strength Development in Ultra High Strength Concrete Using the Electric Arc Furnace Oxidizing Slag as Fine Aggregate, Journal of the Korea Concrete Institute, 25, 3-9. https://doi.org/10.4334/JKCI.2013.25.1.003
  7. Lim H. S., and Lee H. S. (2011), Experimental Study on the Development of X-ray Shielding Concrete Utilizing Electronic Arc Furnace Oxidizing Slag, Architectural Institute of Korea, 27, 125-132.
  8. Lim H. S., and Lee H. S. (2017), Experimental Study on Evaluation on Volume Stability of the Electric Arc Furnace Oxidizing Slag Aggregate, Korea Institute for Structural Maintenance and Inspection, 21(2), 78-86.
  9. Onoue, K., Tokitsu, M., Ohtsu, M., and Bier, T. A. (2014), Fatigue Characteristics of Steel-making Slag Concrete Under Compression in Submerged Condition, Construction and Building Materials, 70, 231-242. https://doi.org/10.1016/j.conbuildmat.2014.07.107
  10. Ryu D. H., Kim M K. H., Park C. G., and Son Y. S. (2009), The Study of Concrete Basic Properties Using Oxidized Electric Furnace Slag Aggregate, Architectural Institute of Korea, 25, 143-150.
  11. Wamg, G. (2010), Determination of the Expansion Force of Coarse Steel Slag Aggregate, Construction and Building Materials, 24, 1961-1966. https://doi.org/10.1016/j.conbuildmat.2010.04.004
  12. Yamamoto H, Noguchi Y., Chinatsuo N., and Torii T. (2004), Physical and Chemical Stability of Concrete Using Electric Furnace Oxidized Slag, Journal of Japan Concrete Institute, 26, 1641-1646.