참고문헌
- Langer M, Brown R, Urie M, Leong J, Stracher M, Shapiro J. Large scale opt imizat ion of beam weights under dose-volume restrictions. Int J Radiat Oncol Biol Phys. 1990;18:887-93. https://doi.org/10.1016/0360-3016(90)90413-E
- Langer M, Leong J. Optimization of beam weights under dose-volume restrictions. Int J Radiat Oncol Biol Phys. 1987;13:1255-60. https://doi.org/10.1016/0360-3016(87)90203-3
- Morrill SM, Lane RG, Wong JA, Rosen II. Dose-volume considerations with linear programming optimization. Med Phys. 1991;18:1201-10. https://doi.org/10.1118/1.596592
- Low DA, Moran JM, Dempsey JF, Dong L, Oldham M. Dosimetry tools and techniques for imrt. Med Phys. 2011;38:1313-38. https://doi.org/10.1118/1.3514120
- Olch AJ. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance. Med Phys. 2002;29:2159-68. https://doi.org/10.1118/1.1500398
- Ma C, Jiang S, Pawlicki T, Chen Y, Li J, Deng J et al. A quality assurance phantom for imrt dose verification. Phys Med Biol. 2003;48:561. https://doi.org/10.1088/0031-9155/48/5/301
- Berry SL, Sheu R-D, Polvorosa CS, Wuu C-S. Implementation of epid transit dosimetry based on a through-air dosimetry algorithm. Med Phys. 2012;39:87-98.
- Saitoh H, Fujisaki T, Sakai R, Kunieda E. Dose distribution of narrow beam irradiation for small lung tumor. Int J Radiat Oncol Biol Phys. 2002;53:1380-87. https://doi.org/10.1016/S0360-3016(02)02893-6
- Van Esch A, Depuydt T, Huyskens DP. The use of an asibased epid for routine absolute dosimetric pre-treatment verification of dynamic imrt fields. Radiother Oncol. 2004;71:223-34. https://doi.org/10.1016/j.radonc.2004.02.018
- McDermott L, Wendling M, Van Asselen B, Stroom J, Sonke J-J, Van Herk M et al. Clinical experience with epid dosimetry for prostate imrt pre-treatment dose verification. Med Phys. 2006;33:3921-30. https://doi.org/10.1118/1.2230810
- Van Esch A, Vanstraelen B, Verstraete J, Kutcher G, Huyskens D. Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields. Radiother Oncol. 2001;60:181-90. https://doi.org/10.1016/S0167-8140(01)00305-X
- McDermott LN, Wendling M, Sonke J-J, van Herk M, Mijnheer BJ. Replacing pretreatment verification with in vivo epid dosimetry for prostate imrt. Int J Radiat Oncol Biol Phys. 2007;67:1568-77. https://doi.org/10.1016/j.ijrobp.2006.11.047
- Berry SL, Polvorosa C, Cheng S, Deutsch I, Chao KC, Wuu C-S. Initial clinical experience performing patient treatment verification with an electronic portal imaging device transit dosimeter. Int J Radiat Oncol Biol Phys. 2014;88:204-09. https://doi.org/10.1016/j.ijrobp.2013.09.045
- Oldham M, Sakhalkar H, Guo P, Adamovics J. An investigation of the accuracy of an imrt dose distribution using two-and three-dimensional dosimetry techniques. Med Phys. 2008;35:2072-80. https://doi.org/10.1118/1.2899995
- Sabet M, Rowshanfarzad P, Vial P, Menk FW, Greer PB. Transit dosimetry in imrt with an a-si epid in direct detection configuration. Phys Med Biol. 2012;57:N295. https://doi.org/10.1088/0031-9155/57/15/N295
- Baek TS, Chung EJ, Koh EK, Seo J, Yoon M. Evaluation of the accuracy of dose delivery for imrt based on transit dosimetry. Health Phys. 2014;107:200-5. https://doi.org/10.1097/HP.0000000000000098
- Baek TS, Chung EJ, Son J, Yoon M. Feasibility study on the verification of actual beam delivery in a treatment room using epid transit dosimetry. Radiat Oncol. 2014;9:273. https://doi.org/10.1186/s13014-014-0273-8
- Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25:656-61. https://doi.org/10.1118/1.598248
피인용 문헌
- Possibility of Interchanging Patients for Beam-Matched Linear Accelerators from the Same Vendor vol.75, pp.8, 2017, https://doi.org/10.3938/jkps.75.628
- Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator vol.43, pp.2, 2017, https://doi.org/10.17946/jrst.2020.43.2.105