DOI QR코드

DOI QR Code

The Study on Marginal discrepancy of Manufactured Coping Crown according to Production method and materials by using CAD/CAM System

CAD/CAM System을 활용하여 제작된 Coping Crown의 제작방식 및 재료에 따른 변연 적합도에 관한 연구

  • Lee, Hee-Sung (Department of Dental Science, Graduate School, Kyungpook National University) ;
  • Shin, Seong-Hun (Daesung Industrial Co., Ltd.) ;
  • Song, Joon-Ki (Department of Prosthodontics, Graduate School, Dankook University)
  • 이희성 (경북대학교 치의과학과) ;
  • 신성훈 (대성산업(주) 기계사업부) ;
  • 송준기 (단국대학교 치의학과)
  • Received : 2017.08.08
  • Accepted : 2017.10.13
  • Published : 2017.10.31

Abstract

The purpose of this study was to compare the marginal discrepancy of coping crowns according to manufacturing method and materials by using the CAD/CAM system to compare the optimum manufacturing method and materials. The coping crowns were fabricated by using manufacturing methods and materials, and marginal fit was measured using the replica technique. For comparative analysis of manufacturing methods and materials, analysis of variance was performed. One-way ANOVA was performed to compare and analyze different mean values. For the milling method of the alloy, 114.6 was obtained for the MM group, 111.4 for the MS group, 67.2 for the MSC group, and 50.9 for the MSS group, respectively, using the milling/sintering method. In the milling/sintering method of ceramic, 35.6 and 36.3, respectively, were obtained for the SLME group and SLMR group, respectively. However,there was a significant difference according to the material. The milling/sintering method of the ceramic material gave the lowest value, and it was verified by the optimal method. However, marginal discrepancy of coping crowns fabricated using the CAD/CAM system is applicable to the clinic since it corresponds to acceptable numerical values in clinical practice.

본 연구는 CAD/CAM 시스템을 활용하여 제작방식 및 재료에 따른 Coping crown의 변연 적합도를 비교하여 최적의 제작방식 및 재료를 비교하고자 하였다. 제작방식 및 재료에 따른 코핑 크라운을 제작하였고, 리플리카 테크닉을 사용하여 변연적합도 측정을 실시하였다. 제작법과 재료에 따른 비교분석을 위해 이원배치분산 분석을 실시하였으며 서로 다른 평균값들의 비교 분석을 위해서 일원배치분산분석을 실시하였다. 연구결과 합금을 Milling법으로 제작한 MM군은 114.6, MS군은 111.4 값을 나타냈고, Milling/Sintering 법으로 제작한 MSC군은 67.2, MSS군은 50.9값을 나타냈고, Printing 법으로 제작한 SLME군은 100.5, SLMR군은 113.2값을 나타냈고, 세라믹의 Milling/Sintering 법으로 제작한 MSZ군은 35.6, MSC군은 36.3값을 나타냈고, 제작방식과 재료에 따른 이원배치분산분석 결과는 제작방식에에 따른 유의한 차이는 보이지 않았으나, 재료에 따른 유의한 차이는 나타내었다. 가장 높은 변연적합도를 보인 군은 세라믹 재료의 Milling/sintering 법이 가장 낮은 값을 보이며 최적의 방법으로 검증이 되었다. 그러나 CAD/CAM 시스템을 활용하여 제작된 Coping crown의 변연 적합도는 임상에서 허용이 가능한 수치값에 해당하므로 임상에 적용이 가능한 것으로 나타났다.

Keywords

References

  1. S. C. Kim, H. H. Lee, "Marginal Accuracy of Three-Unit Bridge Fabricated Using Dental Co-Cr CAD/CAM Soft Metal Block", Kor J Dent Mater, vol. 43, no. 2 pp. 177-184, June, 2016. DOI: http://dx.doi.org/10.14815/kjdm.2016.43.2.177
  2. R. Luthard, A. Weber, H. Rudolph, S. Quaas, M. Walter, "Design and production of dental prosthetic restoration: basic research on dental CAD/CAM technology", Int J Comput Dent, vol. 5, no. 2-3 pp. 165-176, April, 2002.
  3. J. B. Huh, C. G. Park, H. Y. Kim, C. K. Park, S. W. Shin, "Evaluation using Replica Technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems", vol. 48, no. 2 pp. 135-142, April, 2010. DOI: http://dx.doi.org/10.4047/jkap.2010.48.2.135
  4. V. Vera, E. Corchado, R. Redondo, J. Sedano, A. E. Garcia, "Applying soft computing techniques to optimise a dental milling process", Neurocomputing, vol. 109, no. 3 pp. 94-104, October, 2012. DOI: http://dx.doi.org/10.1016/j.neucom.2012.04.033
  5. J.K. Jung, S. O. Lee, K. B. Kim, "Evaluation of shear bond strength between metal core fabricated by 3D printing and dental porcelain". Journal of the Korea Academia-Industrial cooperation Society, vol. 16, no. 4 pp. 2585-2592, April, 2015. DOI: http://dx.doi.org/10.14347/kadt.2012.34.2.105
  6. C. Besimo, C. Jeger, R. Guggenheim, "Marginal adaptation of titanium frameworks produced by CAD/CAM technique", Int J Prosthodont, vol. 10, no. 6 pp. 541-546, Dec. 1997.
  7. Y. Kokubo, M. Tsumita, T. Kano, S. Sakurai, S. Fukushima, "Clinical marginal and internal gaps of zirconia all-ceramic crowns", J Prosthodont Res, vol. 55, no. 1 pp. 40-43, Jan. 2011. DOI: http://dx.doi.org/10.1016/j.jpor.2010.09.001
  8. M. S. Han, E. J. Kwon, E. Chio, S. C. Kim, "Comparison of the fit of the coping pattern constructed by manual and CAD/CAM, depending on the margin of the abutment tooth", Journal of the Korea Academia-Industrial cooperation Society, vol. 16, no. 10 pp. 6611-6617, October, 2015. DOI: http://dx.doi.org/10.5762/KAIS.2015.16.10.6611
  9. D. Felton, B. Kanoy, SA. Bayne, G. Wirthman, " Effect of in vivo crown margin discrepancies on periodontal health", J Prosthet Dent, vol. 65. no. 3 pp. 357-364, March, 1991. DOI: http://dx.doi.org/10.1016/0022-3913(91)90225-L
  10. S. H. Oh, H. B. Shi, H. R. Noh, J. H. Ji, M. H. Lee, T. S. Bae, "Evaluation of Marginal and Internal Fitness of Zirconia Cores Fabricated on Abutments Prepared with Four Different Tip-designed Burs", Korean Journal of Dental Materials, vol. 43, no. 3. pp. 281-288, September, 2016. DOI: http://dx.doi.org/10.14815/kjdm.2016.43.3.281
  11. J. R. Gavelis, J. D. Morency, E. D. Riley, R. B. Sozio, "The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations", J Prosthet Dent, vol. 92, no. 1 pp. 1-7, July, 2004. DOI: http://dx.doi.org/10.1016/0022-3913(81)90330-9
  12. S. C. Kim, M. S. Han, B. J. Choi, C. J. Lee, H. H. Lee, "Internal fit of bridge patterns fabricated by a 3D printing technique", Kor J Dent Mater, vol. 41, no. 4 pp. 239-244, December, 2014. DOI: http://dx.doi.org/10.14815/kjdm.2014.41.4.239
  13. S. Witkowski, F. Komine, T. Gerds, "Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques", J Prosthet Dent, vol. 96, no. 1 pp. 47-52, July, 2006. DOI: http://dx.doi.org/10.1016/j.prosdent.2006.05.013
  14. P. L. Tan, D. G. Gratton, A. M. Diaz-Arnold, D C. Holmes, "An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations", J Prosthodont, vol. 17 no. 5 pp. 378-383, July, 2008. DOI: http://dx.doi.org/10.1111/j.1532-849X.2008.00302.x
  15. H. Y. Rahme, G. E. Tehini, S. M. Adib, A. S. Ardo, K. T. Rifai, "In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns", J Contemp Dent Pract, vol. 9 no. 2 pp. 25-32, Feb. 2008.
  16. K. Quante, K. Ludwig, M. Kern, "Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology", Dent Mater, vol. 24, no. 10 pp. 1311-1315, October, 2008. DOI: http://dx.doi.org/10.1016/j.dental.2008.02.011
  17. D. Assif, Y. Rimer, I. Aviv, "The f low of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application", Quitessence Int, vol. 18, no. 11 pp. 765-774, Nov. 1987.
  18. J. W. McLean, J. A. Fraunhofer, "The estimation of cement film thickness by an in vivo technique", J Br Dent, vol. 131. no. 1 pp. 107-111, Aug. 1971. DOI: http://dx.doi.org/10.1038/sj.bdj.4802708
  19. H. A. Mously, M. Finkelman, R. Zandparsa, H. Hirayama, "Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique", Journal of Prosthetic Dentistry, vol. 112. no. 2 pp. 249-256, Aug. 2014. DOI: http://dx.doi.org/10.1016/j.prosdent.2014.03.017
  20. M. R. Francisco, J. S. Maria, P. Guillermo, "Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings", Journal of Prosthetic Dentistry, vol. 105. no. 2 pp. 108-114, February, 2011. DOI: http://dx.doi.org/10.1016/S0022-3913(11)60009-7