DOI QR코드

DOI QR Code

Long Term Operation and Improvement Reliability for SOFC System

SOFC 시스템의 장시간 운전 및 시스템 신뢰성 향상

  • 이용 (경동나비엔 신재생시스템연구소) ;
  • 신석재 (경동나비엔 신재생시스템연구소) ;
  • 박세진 (경동나비엔 신재생시스템연구소) ;
  • 김민수 (경동나비엔 신재생시스템연구소) ;
  • 김현중 (경동나비엔 신재생시스템연구소) ;
  • 김준호 (경동원 NE연구소) ;
  • 김인환 (경동원 NE연구소) ;
  • 김용수 (경동원 NE연구소)
  • Received : 2017.08.10
  • Accepted : 2017.10.30
  • Published : 2017.10.30

Abstract

Design, manufacture and operate the 700W Solid oxide fuel cell system suitable for housing. Except for BOP not produced domestically, most of the domestic BOPs were applied as much as possible. Finally, the system size was 350 liter. System performance was electric efficiency 44.64%, thermal efficiency 40.99%, total efficiency 85.62% at certificate authority. The system was operated for 4,500 hours, this operation time include automatically system on/off, E-stop for emergency stop, load trip for blackout and inverter error. There were that the system on/off were 26 times. System performance remains intact after system on/off.

Keywords

References

  1. Z. U. Dun and Z. A. Zainal, "Biomass intergrated gasficaion-SOFC systems: Technology overview", Renewable and Sustainable Energy Reviews, Vol. 53, 2016, pp. 1356-1376. https://doi.org/10.1016/j.rser.2015.09.013
  2. Y. M. Son, "Fuel cell based CHP technologies for residential sector", Journal of Energy Engineering, Vol. 25, No. 4, 2016, pp. 251-258. https://doi.org/10.5855/ENERGY.2016.25.4.251
  3. Y. Lee, C. Yang, C. Yang, S. Park, and S. Park, "Optimization of operating conditions for a 10 kW SOFC system", Trans. Korean Hydrogen and New Energy Society, Vol. 27, No 1, 2016, pp. 49-62. https://doi.org/10.7316/KHNES.2016.27.1.049
  4. Y. D. Lee, S. Kang, K. Y. Ahn, and G. Tsatsaronis, "Environmental Impact Assessment of an SOFC-based CHP System", Proceeding of KSME, Vol. 2014, pp. 1327-1332.
  5. J. H. Jeong, J. Y. Han, Y. W. Sung, and S. S. Yu, "Design of LQR Controller for Thermal Management System of 5KW Solid Oxide Fuel Cell", Trans. Korean Soc. Mech. Eng. B, Vol. 39, No. 6, 2015, pp. 505-511. https://doi.org/10.3795/KSME-B.2015.39.6.505
  6. KGS AB934.