References
- 공동주택 성능기반 내진설계 지침, 대한건축학회 (2015)
- Park, Hong-Gun, and Eom, Tae-Sung (2017) "Factored Modal Combination for Evaluation of Earthquake Load Profiles", Journal of Structural Engineering, ASCE,
- Standard, British. (2005) Eurocode 8: Design of structures for earthquake resistance.
- American Concrete Institute: ACI 318-11 (2011) Building Code Requirements for Structural Concrete and Commentary, Farmington Hills, MI.
- 엄태성(2002) 벽식구조의 내진안전성평가, 석사학위논문, 서울대학교.
- 박은진(2017) 편심압축하중을 받는 철근콘크리트 벽체의 전단강도 평가, 석사학위논문, 단국대학교.
- Yuen, Y. P., &Kuang, J. S. (2014). "Axial compression effect on ductility design of RC structural walls". In 2nd European Conference on Earthquake Engineering and Seismology, 1-11.
- Cardenas, A. E., Hanson, J. M., Corley, W. G., &Hognestad, E. (1973). "Design provisions for shear walls." ACI Journal, 70(3), 221-230.
- Zhang, Y., &Wang, Z. (2000). "Seismic behavior of reinforced concrete shear walls subjected to high axial loading." Structural Journal, 97(5), 739-750.
- 윤현도, 최창식, &이리형. (1993). "철근 콘크리트 저형 전단벽의 전단강도 (Shear Strength of Low-Rise Reinforced Concrete Shear Walls)", 대한건축학회 논문집, 9(7), 163-170.
- 이상호, 오상훈, 황원태, 이경보, &이한선. (2010). " 층 RC 전단벽식 구조물의 내진성능에 대한 정적 실험", Jorunal of the Earthquake Engineering Society of Korea, 14(6), 55-65. https://doi.org/10.5000/EESK.2010.14.6.055
- W.G. Corley, A.E. Fiorato, and R.G. Oesrerle. "Structural Walls", ACI SP 72-4, ACI, pp.77-131.
- Tran, T. A., &Wallace, J. W. (2012). "Experimental Study of the Lateral Load Response of Moderate Aspect Ratio Reinforced Concrete Structural Walls." Research Report.
- OLIVARI, C. N. A. (2013). "Influence of axial load in the seismic behavior of reinforced concrete walls with nonseismic detailing" Doctoral dissertation, Pontificia Universidad Catolica De Chile,
- Wong, S. M. (2005). "Seismic performance of reinforced concrete wall structures under high axial load with particular application to low-to moderate seismicregions". 香港大學學位論文, 1-0.
- Krolicki, J., Maffei, J., &Calvi, G. M. (2011). "Shear strength of reinforced concrete walls subjected to cyclic loading", Journal of Earthquake Engineering, 15(S1), 30-71. https://doi.org/10.1080/13632469.2011.562049
- Hou, H., Ye, H., Qu, B., Ma, T., Liu, X., Chen, L., &Zhang, S. (2016). "Precast segmental reinforced concrete walls under eccentric compressive loading: An experimental study", Engineering Structures, 113, 79-88. https://doi.org/10.1016/j.engstruct.2016.01.034
- Mostofinejad, D., &Anaei, M. M. (2012). "Effect of confining of boundary elements of slender RC shear wall by FRP composites and stirrups." Engineering Structures, 41, 1-13. https://doi.org/10.1016/j.engstruct.2012.03.019
- Psilla, N., &Tassios, T. P. (2009). "Design models of reinforced masonry walls under monotonic and cyclic loading. Engineering Structures", 31(4), 935-945. https://doi.org/10.1016/j.engstruct.2008.12.003
- Dolan, J. D., &Johnson, A. C. (1996). "Monotonic tests of long shear walls with openings." Rep. TE-1996, 1.
- Lefas, I. D., Kotsovos, M. D., &Ambraseys, N. N. (1990). "Behavior of reinforced concrete structural walls: strength, deformation characteristics, and failure mechanism", Structural Journal, 87(1), 23-31.