DOI QR코드

DOI QR Code

Anatomical Variants of Lister's Tubercle: A New Morphological Classification Based on Magnetic Resonance Imaging

  • Received : 2016.07.17
  • Accepted : 2017.01.27
  • Published : 2017.12.01

Abstract

Objective: Lister's tubercle is used as a standard anatomical landmark in hand surgery and arthroscopy procedures. In this study, we aimed to evaluate and propose a classification for anatomical variants of Lister's tubercle. Materials and Methods: Between September 2011 and July 2014, 360 MRI examinations for wrists performed using 1.5T scanners in a single institution were retrospectively evaluated. The prevalence of anatomical variants of Lister's tubercle based on the heights and morphology of its radial and ulnar peaks was assessed. These were classified into three distinct types: radial peak larger than ulnar peak (Type 1), similar radial and ulnar peaks (Type 2) and ulnar peak larger than radial peak (Type 3). Each type was further divided into 2 subtypes (A and B) based on the morphology of the peaks. Results: The proportions of Type 1, Type 2, and Type 3 variants in the study population were 69.2, 21.4, and 9.5%, respectively. For the subtypes, the Type 1A variant was the most common (41.4%) and conformed to the classical appearance of Lister's tubercle; whereas, Type 3A and 3B variants were rare configurations (6.4% and 3.1%, respectively) wherein the extensor pollicis longus tendon coursed along the radial aspect of Lister's tubercle. Conclusion: Anatomical variations of Lister's tubercle have potential clinical implications for certain pathological conditions and pre-procedural planning. The proposed classification system facilitates a better understanding of these anatomical variations and easier identification of at-risk and rare variants.

Keywords

References

  1. Saffar P, Fakhoury B. [Secondary repair of the extensor pollicis longus]. Ann Chir Main 1987;6:225-229 https://doi.org/10.1016/S0753-9053(87)80064-9
  2. Hazani R, Engineer NJ, Cooney D, Wilhelmi BJ. Anatomic landmarks for the first dorsal compartment. Eplasty 2008;8:e53
  3. Smith J, Rizzo M, Finnoff JT, Sayeed YA, Michaud J, Martinoli C. Sonographic appearance of the posterior interosseous nerve at the wrist. J Ultrasound Med 2011;30:1233-1239 https://doi.org/10.7863/jum.2011.30.9.1233
  4. Ikiz ZA, Ucerler H. Anatomic characteristics and clinical importance of the superficial branch of the radial nerve. Surg Radiol Anat 2004;26:453-458 https://doi.org/10.1007/s00276-004-0256-9
  5. Smith DK. Dorsal carpal ligaments of the wrist: normal appearance on multiplanar reconstructions of threedimensional Fourier transform MR imaging. AJR Am J Roentgenol 1993;161:119-125 https://doi.org/10.2214/ajr.161.1.8517289
  6. Lohman M, Vasenius J, Nieminen O. Ultrasound guidance for puncture and injection in the radiocarpal joint. Acta Radiol 2007;48:744-747 https://doi.org/10.1080/02841850701422146
  7. Slutsky DJ. Wrist arthroscopy. In: Wolfe SW, Hotchkiss RN, Pederson WC, Kozin SH, eds. Green's operative hand surgery. 6th ed, Philadelphia: Elsevier, 2011:709-741
  8. Berger RA. A method of defining palpable landmarks for the ligament-splitting dorsal wrist capsulotomy. J Hand Surg Am 2007;32:1291-1295 https://doi.org/10.1016/j.jhsa.2007.07.023
  9. Barbieri CH, Mazzer N. Triradiate skin incision for dorsal approach to the wrist. J Hand Surg Br 1996;21:21-23
  10. Samarakoon LB, Lakmal KC, Thillainathan S, Bataduwaarachchi VR, Anthony DJ, Jayasekara RW. Anatomical relations of the superficial sensory branches of the radial nerve: a cadaveric study with clinical implications. Patient Saf Surg 2011;5:28 https://doi.org/10.1186/1754-9493-5-28
  11. Galvis EJ, Kumar KK, Ozyurekoglu T. Radioscapholunate arthrodesis using low-profile dorsal pi plate. Tech Hand Up Extrem Surg 2013;17:80-83 https://doi.org/10.1097/BTH.0b013e318280e9cc
  12. Espen D. [Fixation of fractures of the distal radius using the "nail-plate"]. Oper Orthop Traumatol 2009;21:459-471 https://doi.org/10.1007/s00064-009-1912-3
  13. Hochwald NL, Levine R, Tornetta P 3rd. The risks of Kirschner wire placement in the distal radius: a comparison of techniques. J Hand Surg Am 1997;22:580-584
  14. Pichler W, Windisch G, Schaffler G, Rienmuller R, Grechenig W. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur Vol 2009;34:598-602 https://doi.org/10.1177/1753193409101471
  15. Agir I, Aytekin MN, Kucukdurmaz F, Gokhan S, Cavus UY. Anatomical localization of Lister's tubercle and its clinical and surgical importance. Open Orthop J 2014;8:74-77 https://doi.org/10.2174/1874325001408010074
  16. Kaplan EB. Anatomical variations of the forearm and hand. In: Tubiana R, ed. The hand. Philadelphia: W. B. Saunders, 1981:361-374
  17. Valentin P. Extrinsic muscles of the hand and wrist: an introduction. In: Tubiana R, ed. The hand. Philadelphia: WB Saunders, 1981:243
  18. Clement H, Pichler W, Nelson D, Hausleitner L, Tesch NP, Grechenig W. Morphometric analysis of Lister's tubercle and its consequences on volar plate fixation of distal radius fractures. J Hand Surg Am 2008;33:1716-1719 https://doi.org/10.1016/j.jhsa.2008.08.012
  19. Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS. Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 2006;451:218-222 https://doi.org/10.1097/01.blo.0000223998.02765.0d
  20. Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand (N Y) 2007;2:144-150 https://doi.org/10.1007/s11552-007-9038-2
  21. Ozer K, Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. Hand (N Y) 2011;6:190-193 https://doi.org/10.1007/s11552-010-9316-2
  22. Lamas C, Llusa M, Mendez A, Proubasta I, Carrera A, Forcada P. Intraosseous vascularity of the distal radius: anatomy and clinical implications in distal radius fractures. Hand (N Y) 2009;4:418-423 https://doi.org/10.1007/s11552-009-9204-9
  23. Shima H, Ohno K, Michi K, Egawa K, Takiguchi R. An anatomical study on the forearm vascular system. J Craniomaxillofac Surg 1996;24:293-299 https://doi.org/10.1016/S1010-5182(96)80062-X
  24. Lanzetta M, Howard M, Conolly WB. Post-traumatic triggering of extensor pollicis longus at the dorsal radial tubercle. J Hand Surg Br 1995;20:398-401 https://doi.org/10.1016/S0266-7681(05)80102-0
  25. Stahl S, Wolff TW. Delayed rupture of the extensor pollicis longus tendon after nonunion of a fracture of the dorsal radial tubercle. J Hand Surg Am 1988;13:338-341 https://doi.org/10.1016/S0363-5023(88)80004-2
  26. Ferreres A, Llusa M, Garcia-Elias M, Lluch A. A possible mechanism of direct injury to the EPL tendon at Lister's tubercle during falls with the wrist fully extended. J Hand Surg Eur Vol 2008;33:149-151
  27. Rowland P, Phelan N, Gardiner S, Linton KN, Galvin R. The effectiveness of corticosteroid injection for de Quervain's stenosing tenosynovitis (DQST): A Systematic Review and meta-analysis. Open Orthop J 2015;9:437-444 https://doi.org/10.2174/1874325001509010437
  28. Nishijo K, Kotani H, Miki T, Senzoku F, Ueo T. Unusual course of the extensor pollicis longus tendon associated with tenosynovitis, presenting as de Quervain disease--a case report. Acta Orthop Scand 2000;71:426-428 https://doi.org/10.1080/000164700317393484
  29. De Maeseneer M, Marcelis S, Osteaux M, Jager T, Machiels F, Van Roy P. Sonography of a rupture of the tendon of the extensor pollicis longus muscle: initial clinical experience and correlation with findings at cadaveric dissection. AJR Am J Roentgenol 2005;184:175-179 https://doi.org/10.2214/ajr.184.1.01840175
  30. Perugia D, Ciurluini M, Ferretti A. Spontaneous rupture of the extensor pollicis longus tendon in a young goalkeeper: a case report. Scand J Med Sci Sports 2009;19:257-259

Cited by

  1. Age of Data in Contemporary Research Articles Published in Representative General Radiology Journals vol.19, pp.6, 2018, https://doi.org/10.3348/kjr.2018.19.6.1172
  2. Ultrasound assessment of extensor pollicis longus tendon rupture following distal radius fracture: a sonographic and surgical correlation vol.20, pp.80, 2020, https://doi.org/10.15557/jou.2020.0001