A study on the usefulness of a fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT of severely injured patient

중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구

  • Seo, Sun-Youl (Department of Radiological Science, Eulji University School of Health Science) ;
  • Han, Man-Seok (Department of Radiological Science, Kangwon National University) ;
  • Kim, Chang-Gyu (Department of Radiological Science, Gimcheon University) ;
  • Jeon, Min-Cheol (Department of Radiology, Daejeon Health Institute of Technology) ;
  • Kim, Yong-Kyun (Department of Radiotechnology, Daewon University) ;
  • Kim, Gab-Jung (Department of Radiotechnology, Song-ho University)
  • Received : 2017.08.08
  • Accepted : 2017.09.20
  • Published : 2017.09.28

Abstract

The purpose of this study is to evaluate the usefulness of a newly fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT(computed tomography) of severely injured patient. Radiation dose was measured in the heart, both axillary and thyroid areas using newly designed cloak shield and existing shield with head phantom and human phantom under the same conditions as brain vascular CT scan. The newly designed cloak shield was measured higher for radiation shielding rate than the existing shields, 61.9 % for heart, 46.2 % for left axillary, 69.8 % for right axillary and 71.1 % for thyroid gland, respectively. a newly developed fusion model of cloak shields are useful for reducing radiation exposure. It is expected to make a significant contribution to reduction of radiation exposure.

중증외상 환자 CT(Computed Tomography)검사 시 검사 보조자의 방사선 피폭경감을 위하여 새로운 융합적 모델의 망토 차폐체를 제작하여 그 유용성을 평가하고자 한다. 실험 방법으로 뇌혈관 CT 검사와 동일한 조건에서 두부 팬텀과 인체 팬텀을 이용하여 기존 차폐체와 새롭게 개발된 망토 차폐체를 이용하여 심장, 양쪽 액와부 그리고 갑상샘 부위를 유리선량계로 피폭선량을 측정하였다. 새롭게 개발된 차폐체가 기존의 차폐체 보다 방사선 차폐율이 심장 61.9 %, 좌측액와부 46.2 %, 우측액와부 69.8 %, 그리고 갑상샘 71.1 % 로 각각 높게 측정되었다. 새롭게 개발된 망토 차폐체가 방사선 피폭을 감소시키는데 매우 유용하며 향후 새롭게 개발된 융합적 모델의 망토 차폐차가 방사선 피폭을 감소시키는데 있어 큰 기여를 할 것으로 판단된다.

Keywords

References

  1. Korea Centers for Disease Control and Prevention, 2013 Report Occupational Radiation Exposure in Diagnostic Radiology in Korea, No. 3, 2014.
  2. S. J. Yoo "A study on performance evaluation of Apron by shielding rate and uniformity" J. Korea Saf. Manag. Sci. Vol. 17 No. 1, pp 103-109, 2015. https://doi.org/10.12812/ksms.2015.17.1.103
  3. S. K. Na, B. S. Park, Y. G. Kang, " Study of occupational exposure in PET/CT" J. of Digital Convergence, Vol 10, No 11, pp. 449-457, 2012. https://doi.org/10.14400/JDPM.2012.10.11.449
  4. H. R. Jung, K. J. Kim, E. H. Mo, "A Study on the Radiation Expsure Dose of Brain Perfusion CT Examination a Pantom" J. of Digital Convergence, Vol 6, No 5, pp. 287-294, 2015.
  5. Whal Lee, "Current status of medical radiation exposure and regulation efforts", J. of Korean Medical Assoc, Vol 54, No. 12, pp. 1248-1252, 2011. https://doi.org/10.5124/jkma.2011.54.12.1248
  6. D. H. Kim, S. H. Kim, " Convergence Performance Evaluation of Radiation Protection for Apron using the PSNR" J. of Digital Convergence, Vol 13, No 10, pp. 377-383, 2015. https://doi.org/10.14400/JDC.2015.13.10.377
  7. The Korea Ministry of Health and Welfare, Diagnostic Radiology Safety Management Rules, 2015.
  8. The Korea Ministry of Food and Drug Safety, 4. Standard Specifications for Electronic Medical Device, 2014.
  9. S. S Chu, "Radiation safety management status according to the medical use of radiation", Korean Association for Radiation Protection, Vol 15, No. 1, pp. 39-46, 1990.
  10. D. K Kwon, "Improvement of Medical Radiation Exposure Management, J. The Korean Radiolothechnology, Vol. 26, No. 1, pp 9-40, 2000.
  11. ICRP. 1977, "Recommendations of the International Commission on Radiological Protection, Publication 26, 1977.
  12. B.S Lim, "Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea", J of Korean Society of Radiological Technology, Vol 29, No. 3, pp. 185-195, 2006.
  13. T.S Jeong, "The Analysis of Radiation Exposure of Hospital Radiation Workers", Journal of the Korean Society for Therapeutic Radiology and Oncology, Vol 18, No. 2, pp. 157-166, 2000.
  14. ICRP. 2007, "Recommendations of the International Commission on Radiological Protection, Publication 103, 2007.
  15. S. H Kim, Y. S Park, T. I Kim, C. M Kim, and J. S, Oh, "Performance evaluation of Apron and Thyroid Protector", J. of The Korean Society of Cardio-Vascular Interventional Technology, Vol 15, No. 1, pp. 110-115, 2012.
  16. Y. K. Kim, Y. I. Jang and J. M. Kim, "Improvement of the Shieldability and lightweight of a radiation protective apron" J. of The Korean Society of Cardio-Vascular Interventional Technology, Vol 26, No. 1, pp. 45-50, 2003.
  17. H. J. Yang, Y. S. Jeon, K. C. Lee, I. J. Lee, S. S. Lee, Jun Heo, "Evaluation of Performance Test for Protective Aprons", J. of Korean Society of Radiological Technology, Vol 16, No. 2, pp. 73-79, 1993.
  18. ICRP. 1997, "Recommendations of the International Commission on Radiological Protection, Publication 73, 1997.