The seismic reliability of two connected SMRF structures

  • Aval, Seyed Bahram Beheshti (Department of Structural Engineering, Faculty of Civil Engineering, K.N. Toosi University of Technology) ;
  • Farrokhi, Amir (Department of Structural Engineering, Faculty of Civil Engineering, K.N. Toosi University of Technology) ;
  • Fallah, Ahmad (Department of Structural Engineering, Faculty of Civil Engineering, K.N. Toosi University of Technology) ;
  • Tsouvalas, Apostolos (Department of Structural Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology)
  • Received : 2017.02.20
  • Accepted : 2017.07.10
  • Published : 2017.08.25

Abstract

This article aims to investigate the possible retrofitting of a deficient building with soft story failure mode by connecting it to an adjacent building which is designed based on current code with friction dampers at all floors. Low cost and high performance reliability along with significant energy dissipation pertaining to stable hysteretic loops may be considered in order to choose the proper damper for connecting adjacent buildings. After connecting two neighbouring floors by friction dampers, the sliding forces of dampers at various stories are set in two arrangements: uniform sliding force and then variable sliding force. In order to account for the stochastic nature of the seismic events, incremental dynamic analyses are employed prior and after the installation of the friction dampers at the various floors. Based on these results, fragility curves and mean annual rate of exceedance of serviceability and ultimate limit states are obtained. The results of this study show that the collapse mode of the deficient building can affect the optimum arrangement of sliding forces of friction dampers at Collapse Prevention (CP) performance level. In particular, the Immediate Occupancy (IO) performance level is not tangible to the sliding force arrangement and it depends solely on sliding force value. Generally it can be claimed that this rehabilitation scheme can turn the challenge of pounding two adjacent buildings into the opportunity of dissipating a large amount of the seismic input energy by the friction dampers, thus improving significantly the poor seismic performance of the deficient structure.

Keywords

References

  1. Abdeddaim, M., Ounis, A., Shrimali, M.K. and Datta, T.K. (2017), "Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR Dampers", Struct. Eng. Mech., 62(2), 197-208. https://doi.org/10.12989/sem.2017.62.2.197
  2. Abdeddaim, M., Ounis, A., Djedoui, N. and Shrimali, M.K. (2016a), "Pounding hazard mitigation between adjacent planar buildings using coupling strategy", J. Civ. Struct. Hlth. Monit., 6(3), 603-617. https://doi.org/10.1007/s13349-016-0177-4
  3. Abdeddaim, M., Ounis, A., Djedoui, N. and Shrimali, M.K. (2016b), "Reduction of pounding between buildings using fuzzy controller", Asian J. Civ. Eng. (BHRC), 17, 985-1005.
  4. Aiken, I.D. and Kelly, J.M. (1990), "Earthquake simulator testing and analytical studies of two energy-absorbing systems for multistory structures", Earthquake Engineering Research Center (EERC), Report No. UCB/EERC-90/3, University of California at Berkeley, USA.
  5. Asgarian, B., Salehi Golsefidi, E. and Shokrgozar, H.R. (2016), "Probabilistic seismic evaluation of buckling restrained braced frames using DCFD and PSDA methods", Earthq. Struct., 10(1), 105-123. https://doi.org/10.12989/eas.2016.10.1.105
  6. Baker, J.W. (2015), "Efficient analytical fragility function fitting using dynamic structural analysis", Earthq. Spectra, 31(1), 579-599. https://doi.org/10.1193/021113EQS025M
  7. Beheshti Aval, S.B., Khojastehfar, E., Zolfaghari, M. and Nasrollahzadeh, K. (2014), "Collapse fragility curve development using Monte Carlo simulation and artificial neural network", J. Risk Reliability, 228(3), 301-312.
  8. Beheshti Aval, S.B., Masoumi Verki, A. and Rastegaran, M. (2014), "Systematical approach to evaluate collapse probability of steel MRF buildings based on engineering demand and intensity measure", International Conference on Advances in Civil Structural and Mechanical Engineering, Birmingham, United Kingdom, doi: 10.3850/978-981-07-8859-9_28.
  9. Bertero, V.V. and Collins, R.G. (1973), "Investigation of the failures of the Olive View stair-towers during the San Fernando earthquake and their implications on seismic design", Report No. EERC 73-26, Earthquake Engineering Research Center, University of California, Berkeley, USA.
  10. Bharti, D., Dumne, S.M. and Shrimali, M.K. (2010), "Seismic response analysis of adjacent buildings connected with MR dampers", Eng. Struct. J., 32(8), 21-22. https://doi.org/10.1016/j.engstruct.2009.08.013
  11. Bhaskarrao, A.V. and Jangid, R.S. (2006), "Seismic response of adjacent buildings connected with friction dampers", Bull. Earthq. Eng., 4(1), 43-64. https://doi.org/10.1007/s10518-005-5410-1
  12. Bhaskararao, A.V. and Jangid, R.S. (2006), "Harmonic response of adjacent structures connected with a friction damper", J. Sound Vib., 292(3-5), 710-725. https://doi.org/10.1016/j.jsv.2005.08.029
  13. Christenson, R., Spencer, B. and Johnson, E. (2007), "Semiactive connected control method for adjacent multidegree-of-freedom buildings", J. Eng. Mech., 133(3), 290-298. https://doi.org/10.1061/(ASCE)0733-9399(2007)133:3(290)
  14. FEMA 350. (2000), "Recommended seismic design criteria for new steel moment-frame buildings", Washington, DC: SAC Joint Venture, Federal Emergency Management Agency.
  15. Filiatrault, A., Tremblay, R. and Kar, K. (2000), "Performance evaluation of friction spring seismic damper", J. Struct. Eng., 126(4), 491-499. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:4(491)
  16. Gurley, K., Kareem, A., Bergman, L.A., Johnson, E.A. and Klein, R.E. (1994), "Coupling tall buildings for control of response to wind", 6th International Conference on Structural Safety and Reliability, Rotherdam, United Kingdom, 1553-1560.
  17. Iwanami, K., Suzuki, K. and Seto, K. (1986), "Studies of the vibration control method of parallel structures", Trans. JSME, No. 86-0247A, 3063-3072.
  18. Jagadish, G. Kori and Jangid, R.S. (2008) "Semi-active friction dampers for seismic control of structures", Smart Struct. Syst., 4(4), 493-515. https://doi.org/10.12989/sss.2008.4.4.493
  19. Jalayer, F. (2003), "Direct probabilistic seismic analysis: Implementation non-linear dynamic assessments", Ph.D. dissertation, Department of Civil And Environmental Engineering, Stanford University, Stanford.
  20. Jankowski, R. and Mahmoud, S. (2015), Earthquake-Induced Structural Pounding. Switzerland: Springer, ISBN: 978-3-319-16323-93.
  21. Katebi, J. and Mohammady Zadeh, S. (2016) "Time delay study for semi-active control of coupled adjacent structures using MR damper", Struct. Eng. Mech., 58(6), 1127-1143. https://doi.org/10.12989/sem.2016.58.6.1127
  22. Kima, J., Ryua, J. and Chung, L. (2006), "Seismic performance of structures connected by viscoelastic dampers", Eng. Struct., 28(2), 183-195. https://doi.org/10.1016/j.engstruct.2005.05.014
  23. Klein, R.E., Cusano, C. and Stukel, J. (1972), "Investigation of a method to stabilize wind induced oscillations in large structures", New York: American Society of Mechanical Engineers.
  24. Lee, J. and Kim, J. (2015), "Seismic performance evaluation of moment frames with slit-friction hybrid dampers", Earthq. Struct., 9(6), 1291-1311. https://doi.org/10.12989/eas.2015.9.6.1291
  25. Lee, Y.J. and Moon, D.S. (2014), "A new methodology of the development of seismic fragility curves", Smart Struct. Syst., 14(5), 847-867. https://doi.org/10.12989/sss.2014.14.5.847
  26. Luco, J.E. and Debarros, F.C.P. (1998), "Optimal damping between two adjacent elastic structures", Earthq. Eng. Struct. D., 27(7), 649-659. https://doi.org/10.1002/(SICI)1096-9845(199807)27:7<649::AID-EQE748>3.0.CO;2-5
  27. Lignos, D. (2008), "Sideway collapse of deteriorating structural systems under seismic excitations", Ph.D. dissertation, Department of Civil Engineering, Stanford University, Stanford.
  28. Nigdeli, S.M. and Bekdas, G. (2014), "Optimum tuned mass damper approaches for adjacent structures", Earthq. Struct., 7(6), 1071-1091. https://doi.org/10.12989/eas.2014.7.6.1071
  29. Ng, C.L. and Xu, Y.L. (2004), "Experimental study on seismic response Mitigation of complex structure using passive friction damper", ANCER Annual Meeting, Networking of Young Earthquake Engineering Researchers and Professionals, The Sheraton Princess Kaiulani, Honolulu, Hawaii.
  30. Open system for Earthquake Engineering Simulation, OpenSees, (2008), Pacific Earthquake Engineering Research Center, http://peer.berkeley.edu
  31. Palacios-Quinonero, F., Rubio-Massegu, J., Rossell, J.M. and Karimi, H.R. (2014), "Vibration control for adjacent structures using local state information", Mechatronics, 24(4), 336-344. https://doi.org/10.1016/j.mechatronics.2013.08.001
  32. Pall, A.S., Marsh, C. and Fazio, P. (1980), "Friction joints for seismic control of large panel structures", J. Restress. Concrete Inst., 25(6), 38-61.
  33. Park, K.S. and Ok, A.Y. (2015), "Hybrid control approach for seismic coupling of two similar adjacent structures", J. Sound Vib., 349, 1-17. https://doi.org/10.1016/j.jsv.2015.03.028
  34. Patel, C.C. and Jangid, R.S. (2010a), "Seismic response of adjecent structures connected with Maxweel dampers", Asian J. Civ. Eng. (Building and Housing), 11(5), 585-603.
  35. Patel, C.C. and Jangid, R.S. (2010b), "Seismic response of dynamically similar adjacent structures connected with viscous dampers", Inst. Environ. Sci. J., Part A: Civ. Struct. Eng., 3(1), 1-13.
  36. Patel, C.C. and Jangid, R.S. (2010c), "Seismic response of adjacent structures connected with semi-active variable friction dampers", Int. J. Acoust. Vib., 15(1), 39-46.
  37. Patel, C.C. and Jangid, R.S. (2011), "Dynamic response of adjacent structures connected by friction damper", Earthq. Struct., 2(2), 149-169. https://doi.org/10.12989/eas.2011.2.2.149
  38. Penzien, J. (1996), "Evaluation of building separation distance required to prevent pounding during strong earthquakes", Earthq. Eng. Struct. D., 26(8), 849-858. https://doi.org/10.1002/(SICI)1096-9845(199708)26:8<849::AID-EQE680>3.0.CO;2-M
  39. Pujari, N.N., Mandal, T.K., Ghosh, S. and Lala, S. (2013), "Optimization of IDA-based fragility curves", The 11th International Conference on Structural Safety and Reliability, Columbia University, New York.
  40. Setright, L.J.K. and Ward, I. (1976), "Anatomy of the motor car", Unknown publisher, pp. 166, ISBN 0-85613-230-6.
  41. Shrimali, M.K. and Dumne, S.M. (2008), "Seismic analysis of connected isolated buildings by VF dampers", The 14th World Conference on Earthquake Engineering, Beijing, China.
  42. Standard No. 2800. (2007), Iranian Code of Practice for Seismic Resistant Design of Buildings (3rd Ed.). Iran: Building and Housing Research Center.
  43. Uz, M.E. and Hadi, M.N.S. (2014), "Optimal design of semi active control for adjacent buildings connected by MR damper based on integrated fuzzy logic and multi-objective genetic algorithm", Eng. Struct., 69, 135-148. https://doi.org/10.1016/j.engstruct.2014.03.006
  44. Vamvatsikos, D. and Cornell, C.A. (2005), "Developing efficient scalar and vector intensity measures for IDA capacity estimation by incorporating elastic spectral shape information", Earthq. Eng. Struct. D., 34(13), 1573-1600. https://doi.org/10.1002/eqe.496
  45. Wang, J. and Taheri, H. (2014), "Seismic hazard assessment of the Tehran region", Nat. Haz. Rev. J., 15(2), 121-127.
  46. Xu, Y.L., He, Q. and Ko, J.M. (1999), "Dynamic response of damper-connected adjacent buildings under earthquake excitation", J. Eng. Struct., 21(2), 135-148. https://doi.org/10.1016/S0141-0296(97)00154-5
  47. Yang, Z., Xu, Y.L. and Lu, X.L. (2003), "Experimental seismic study of adjacent buildings with fluid dampers", J. Struct. Eng., ASCE, 129(2), 197-205. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:2(197)
  48. Zareian, F., Krawinkler, H., Ibarra, L. and Lignos, D. (2010), "Basic concepts and performance measures in prediction of collapse of buildings under earthquake ground motions", Struct. Des. Tall Spec. Build., 19(1-2), 167-181. https://doi.org/10.1002/tal.546
  49. Zhu, H., Ge, D. and Huang, X. (2011), "Optimum connecting dampers to reduce the seismic responses of parallel structures", J. Sound Vib., 330(19), 31-49.