References
- P. A. Kinie, "Thermocouple Temperature Measurement", Wiley, New York, 1973.
- E. M. Moffatt, "Methods of Minimizing Errors in the Measurement of High Temperatures in Gas", Instruments, Vol. 22, No. 2, pp. 122-132, 1949.
- M. V. Heitor and A. L. N. Moreira, "Thermocouples and Sample Probes for Combustion Studies", Progress in Energy and Combustion Science, Vol. 19, pp. 259-278, 1993. https://doi.org/10.1016/0360-1285(93)90017-9
- J. C. Jones, "On the Use of Metal Sheathed Thermocouples in a Hot Gas Layer Originating from a Room Fire", Journal of Fire Science, Vol. 13, No. 4, pp. 257-260, 1995. https://doi.org/10.1177/073490419501300401
- M. Luo, "Effects of Radiation on Temperature Measurement in a Fire Environment", Journal of Fire Science, Vol. 15, pp. 443-461, 1997. https://doi.org/10.1177/073490419701500602
- L. G. Blevins and W. M. Pitts, "Modeling of bare and Aspirated Thermocouples in Compartment Fires", Fire Safety Journal, Vol. 33, pp. 239-259, 1999. https://doi.org/10.1016/S0379-7112(99)00034-X
- W. M. Pitts, E. Braun, R. D. Peacock, H. E. Mitler, E. L. Johnsson, P. A. Reneke and L. G. Blevins, "Temperature Uncertainties for Bare-Bead and Aspirated Thermocouple Measurements in Fire Environments", Thermal Measurements: The Foundation of Fire Standards, ASTM STP 1427, 2002.
- S. C. Kim and A. Hamins, "On the Temperature Measurement Bias and Time Response of an Aspirated Thermocouple in Fire Environment", Journal of Fire Science, Vol. 26, pp. 509-529, 2008. https://doi.org/10.1177/0734904108093516
- S. Brohez, C. Delvosalle and G. Marlair, "A Two-Thermo-Couples Probe for Radiation Corrections of Measured Temperature in Compartment Fires", Fire Safety Journal, Vol. 39, pp. 399-411, 2004. https://doi.org/10.1016/j.firesaf.2004.03.002
- S. -C. Kim, "A Review of Temperature Measurement of Fire Driven Flow Using Thermocouple - Measurement Bias", Journal of Korean Institute of Fire Science and Engineering, Vol. 24, No. 6, pp. 98-103, 2010.
- G. E. Glawe, F. S. Simmons and T. M. Stickney, "Radiation and Recovery Correction and Time Constant of Several Chomel-Alumel Thermocouple Probe in High Tem-Perature", High Velocity Gas Streams, NACA TN3766, 1953.
- D. Bradley and K. J. Matthews, "Measurement of High Gas Temperature with Fine Wire Thermocouple", Journal of Mechanical Engineering Science, Vol. 10, pp. 299-305, 1968. https://doi.org/10.1243/JMES_JOUR_1968_010_048_02
- K.D. Steckler, J. G. Quintiere and W. J. Rinkinen, "Flow Induced by Fire in a Compartment", National Bureau of Standards Internal Report NBSIR 82-2520, Gaithersburg, Maryland, 1982.
- C. -H. Hwang, A. Lock, M. Bundy, E. Johnsson and G. H. Ko, "Studies on Fire Characteristics in Over- and Underventilated Full-Scale Compartments", Journal of Fire Science, Vol. 28, pp. 459-486, 2010. https://doi.org/10.1177/0734904110363106
- H. -S. Yun, S. -Y. Mun and C. -H. Hwang, "An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions", Journal of Korean Institute of Fire Science and Engineering, Vol. 29, No. 5, pp. 34-41, 2015.