DOI QR코드

DOI QR Code

Employing rotating vaneless diffuser to enhance the performance of plenum fan

  • Dou, Hua-Shu (Faculty of Mechanical Engineering and Automation, Zhejiang Sci-Tech University) ;
  • Wu, Lin (Acon Biotech (Hangzhou) CO., Ltd) ;
  • Wei, Yikun (Faculty of Mechanical Engineering and Automation, Zhejiang Sci-Tech University) ;
  • Chen, Yongning (Zhejiang Yilida Ventilator CO., Ltd) ;
  • Cao, Wenbin (Zhejiang Yilida Ventilator CO., Ltd) ;
  • Ying, Cunlie (Zhejiang Yilida Ventilator CO., Ltd)
  • 투고 : 2015.03.05
  • 심사 : 2016.02.11
  • 발행 : 2017.03.31

초록

Numerical simulation is carried out for flow characteristics in a plenum fan and the influence of the diameter ratio of the rotating vaneless diffuser on the performance of plenum fan is analyzed. The diameter ratio of the rotating vaneless diffuser employed is from 1.03 to 1.3. The research results show that the rotating vaneless diffuser is able to enhance the performance of plenum fan. It is found that there is significant improvement in static pressure and efficiency at the diameter ratio of 1.05 at high flow coefficients, while the optimal diameter ratio is 1.2 at rated and low flow coefficient.

키워드

과제정보

연구 과제 주관 기관 : Natural Science Foundation of Zhejiang Province, National Natural Science Foundation of China

참고문헌

  1. Hou, S. Q., 2006, "Numerical Simulation of the Inner Flow Field in the Centrifugal Fan," Ph. D. Thesis, College of Mechanical and Energy Engineering, Zhejiang University, Hangzhou, CHN (in Chinese).
  2. Chen, Y. L., 2010, "Fan Wall Central-Station Air Handling Units," Refrigeration and Air-Conditioning, Vol. 3, No. 10, pp. 38-40 (in Chinese).
  3. Cheng, X. D., 2006, Centrifugal Fan, Chemical Industry Press, Beijing (in Chinese).
  4. Zuo, W. L., Su, H.Q., Liu, Y.H., 2013, "Simulation and Experimental Study on Flow Deflector of Volutelss Fan," Refrigeration and Air-Conditioning, Vol. 13, No. 10, pp. 29-34(in Chinese).
  5. Liu, C.X., Nie, B., Chen, J.X., 2013, "Research on the Performance of Centrifugal Fan without a Scroll," Fluid Machinery, Vol. 38, No. 4, pp. 4-8 (in Chinese).
  6. Wang S. K., 2001, Handbook of Air Conditioning and Refrigeration, McGraw-Hill, Inc, New York.
  7. Kim, J. H., Cha, K. H., Kim, K. Y., and Jang, C. M., 2012, "Numerical Investigation on Aerodynamic Performance of a Centrifugal Fan with Splitter Blades," International Journal of Fluid Machinery and System, Vol. 5, No. 4, pp. 168-173. https://doi.org/10.5293/IJFMS.2012.5.4.168
  8. Hariharan, C., and Govardhan, M., 2013, "Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute," International Journal of Fluid Machinery and System, Vol. 6, No. 3, pp. 113-120. https://doi.org/10.5293/IJFMS.2013.6.3.113
  9. Dundi, T. M. K., Sitaram, N., and Suresh. M., 2012, "Application of Gurney Flaps on a Centrifugal Fan Impeller," International Journal of Fluid Machinery and System, Vol. 5, No. 2, pp. 65-71. https://doi.org/10.5293/IJFMS.2012.5.2.065
  10. Yang, C. Y., 2012, "The Optimization and Numerical Simulation of Centrifugal Fan," Ph. D. Thesis, Department of mechanical engineering, Anhui University of Science and Technology, Huainan, CHN (in Chinese).
  11. Wu, Y. L., Chen, Q. G., Liu, S. H., 2011, Fans and Compressors, Tsinghua University Press, Beijing (in Chinese).
  12. Senoo, Y., Kinoshita, Y., and Ishida, M., 1977, "Asymmetric Flow in Vaneless Diffusers of Centrifugal Blowers," Journal of Fluid Mechanics, Vol. 99, No. 1, pp. 104-113.
  13. Inoue, M., Cumpsty, N. A., 1984, "Experimental Study of Centrifugal Impeller Discharge Flow in Vaneless and Vaned Diffusers," Jounal of Engineering for Gas Turbines and Power, Vol. 106, No.2, pp. P455-467. https://doi.org/10.1115/1.3239588
  14. Li, H.M., 2012, "Flow in a Single Stage Centrifugal Fan With Vaneless Diffuser and Peripheral Louver Outlets," Journal of Fluids Engineering, Vol. 134, No.10, pp. 101101-1-101101-8. https://doi.org/10.1115/1.4006695
  15. Han, H. Q., and Gu, C. G., 2005, "Numerical Simulation on Flow Field of Vaned Diffuser and Vaneless Diffuser in Single-Stage centrifugal fan," Compressor Blower & Fan Technology, No. 3, pp. 11-25 (in Chinese).
  16. Sato, T., Oh, J. M., and Engeda, A., 2005, "Experimental and Numerical Investigation of the Flow in a Vaneless Diffuser of a Centrifugal Compressor Stage. Part1: Experimental Investigation," Proceedings of the Institution of Mechanical Engineers, part C, Vol. 219, No. 10, pp. 1053-1059.
  17. Sato, T., Oh, J. M., and Engeda, A., 2005, "Experimental and Numerical Investigation of the Flow in a Vaneless Diffuser of a Centrifugal Compressor Stage. Part 2: Numerical Investigation," Proceedings of the Institution of Mechanical Engineers, part C, Vol. 219, No. 10, pp. 1061-1068.
  18. Allos, T., and Elder, R., 1980, "Measurement of Flow Velocity in the Vaneless Diffuser of a High-Speed Centrifugal Compressor Using a Laser Doppler Anemometer," International Journal of Optics, Vol. 27, No. 1, pp. 119-126.
  19. Gao, Y., Meng, L., Jia, L., Tian, R., Li, S., 2012, "Several Problems Found in the Development of Centrifugal Fans Without Housing," Compressor, Blower & Fan Technology, No. 3, pp. 16-19 (in Chinese).
  20. Shih, T., Liou, W. W., and Shabbir, A., 1995, "A New $k-{\epsilon}$ Eddy Viscosity Model for High Reynolds Number Turbulent Flows," Computers & Fluids, Vol. 24, No. 3, pp. 227-238. https://doi.org/10.1016/0045-7930(94)00032-T
  21. Xu, K. C., Wang, H. Q., and Gai, J. F., 2011, Fan Manual, China Machine Press, Beijing (in Chinese).