Study on prestressed concrete beams and poles with cement replaced by steel dust

  • Received : 2017.05.02
  • Accepted : 2017.08.03
  • Published : 2017.08.25

Abstract

Cement acts as the most important component of concrete as it binds and holds the concrete together. But it is one of the major $CO_2$ emitters all over the world, during manufacturing (900 kg of $CO_2$ per 1000 kg). Some of the modern construction methods aim at reducing the amount of usage of cement and came out with numerous solutions for replacement of the same. One such supplement in current trend is the Steel dust or the Electric Arc Furnace Dust (EAFD), which is a waste product from the electric arc furnace when the scrap metal is melted. When the concrete containing steel dust is exposed to atmosphere, the environmental oxygen and moisture play role to form rust and ultimately the member becomes harder. As Cement is the binder of conventional concrete, only certain percentage of the same could be replaced by the new material, steel dust. Tests were conducted for the 28 days cube strength of M45 grade (suitable for prestressing) concrete which has 0%, 10%, 20%, 30%, 40% and 50% steel dust instead cement. From the test, the optimum percentage replacement of steel dust was obtained, for which the beams and overhead poles were cast, prestressed and tested for the failure load and deflections. A conventional concrete beam and overhead pole were also cast, prestressed and tested to compare the results with those of the beam and pole that contained steel dust. The load vs. deflection plot and other results from the test is also discussed.

Keywords

References

  1. Ananthi, A. and Karthikeyan, J. (2015), "A review on the effect of industrial waste in concrete", Ind. Concrete J., 73.
  2. Ajinkya, A., Choure, A.P., Pagare, S.D., Jaybhaye, D.W. and Gawatre. (2015), "Use of steel dust as a Admixture in concrete mix design", J. Res. Eng. Sci. Technol., 1, 2395-6453.
  3. De Vargas, A.S., Masuero, A.B. and Vilela, A.C. (2006), "Investigations on the use of electric-arc furnace (EAFD) in Pozzolan-modified Portland cement I (MP) pastes", J. Cement Concrete Res., 36(10), 1833-1841. https://doi.org/10.1016/j.cemconres.2006.06.003
  4. Skogman, B.C., Tadros, M.K. and Grasmick, R. (1988), "Flexural strength of prestressed concrete members", PCI J., 33(5), 96-123.
  5. Souza, C.A.C.D., Machado, A.T., Lima, L.R.P.D.A. and Cardoso, R.J.C. (2010), "Stabilization of electricarc furnace dust in concrete", J. Mater. Res., 13(4), 513-519. https://doi.org/10.1590/S1516-14392010000400014
  6. Burke, C.R. and Dolan, C.W. (2001), "Flexural design of prestressed concrete beams using FRP tendons", PCI J., 46, 76-87.
  7. Baran, E., French, C.E. and Schultz, A.E. (2005), "Analysis of the flexural strength of prestressed concrete flanged sections", PCI J., 50(1), 74-93.
  8. Fares, G., Al-Zaid, R.Z., Fauzi, A., Alhozaimy, A.M., Al-Negheimish, A.I. and Khan, M.I. (2016), "Performance of optimized electric arc furnace dust-based cementitious matrix compared to conventional supplementary cementitious materials", J. Constr. Build. Mater., 112, 210-221. https://doi.org/10.1016/j.conbuildmat.2016.02.068
  9. Colorado, H.A., Garcia, E. and Buchely, M.F. (2016), "White ordinary Portland cement blended with superfine steel dust with high oxide contents", J. Constr. Build. Mater., 112, 816-824. https://doi.org/10.1016/j.conbuildmat.2016.02.201
  10. IS 10262 (2009), Concrete Proportioning-Guidelines (First Revision), Bureau of Indian Standards.
  11. IS 1343 (2012), Prestressed Concrete-Code of Practice (Second Revision), Bureau of Indian Standards.
  12. IS 1678 (1998) (Reaffirmed 2003), Prestressed Concrete Poles for Overhead Power Traction and Telecommunication Lines-Specifications (Second Revision), Bureau of Indian Standards.
  13. IS 456 (2000), Plain Reinforced Concrete-Code of Practice (Fourth Revision), Bureau of Indian Standards.
  14. Pitroda, J., Zala, L.B. and Unringar, F.S. (2012), "Experimental Investigations on partial replacement of cement with fly ash in design mix concrete", J. Adv. Eng. Technol., 3(4), 126-129.
  15. Maslehuddin, M., Awan, F.R., Shameem, M., Ibrahim, M. and Ali, M.R. (2011), "Effect of electric arc furnace on the properties of OPC and blended cement concretes", J. Constr. Build. Mater., 25, 308-312. https://doi.org/10.1016/j.conbuildmat.2010.06.024
  16. Mohammad, A. and Alsheyab, T. (2013), "SEM analysis on electron arc furnace dust (EAFD) and EAFD -asphalt mixture", J. Environ. Natur. Res. Res., 3(4), 147.
  17. Dawood, M.B. and Al-Katib, H.H. (2015), "Flexural strength of prestressed concrete beams with openings and strengthened with CFRP sheets", J. Sci. Res., 4(6), 161-172. https://doi.org/10.4103/2320-0057.174865
  18. Cooke, N., Park, R. and Yong, P. (1981), "Flexural strength of prestressed concrete members with unbonded tendons", PCI J., 26(6), 52-80. https://doi.org/10.15554/pcij.11011981.52.81
  19. Pajgade, P.S. and Thakur, N.B. (2013), "Utilisation of waste product of steel industry", J. Eng. Res. Appl., 3(1), 2033-2041.
  20. Acharya, P.K. and Patro, S.K. (2016), "Strength, sorption and abrasion characteristics of concrete using ferrochrome ash (FCA) and lime as partial replacement of cement", J. Cement Concrete Compos., 74, 16-25. https://doi.org/10.1016/j.cemconcomp.2016.08.010
  21. REC (Rural Electrification Corporation) of India Specification No. 15 (1979), Technical Specification for Prestressed Cement Concrete Poles.
  22. Patil, S.P. and Sangle, K.K. (2013), "Flexural strength evaluation of prestressed concrete beams with partial replacement of cement by metakaolin and flyash", Am. J. Res. Sci. Technol. Eng. Math., 3, 187-194.
  23. Kumar, S.E., Maheswari, U.R., Sudha, M., Sheela, S. and Saranya, K. (2015), "Flexural strength evaluation of prestressed concrete beams with partial replacement of coarse aggregate by ceramic wastes", J. Civil Struct. Eng., 6(2), 148.
  24. Swaptik Chowdhury, Mihir Mishra, Om Sugannya, (2015), "The incorporation of wood waste ash as a partial cement replacement material for making structural grade concrete: An overview", Ain Sham. Eng. J., 6(2), 429-437. https://doi.org/10.1016/j.asej.2014.11.005
  25. Lee, S.H., Shin, K.J. and Kang, T.H.K. (2015), "Flexural strengthening of continuous concrete beams using external prestressed steel bars", PCI J., 60(1).
  26. Wang, T.H., Huang, R. and Chang, J.J. (2013), "Flexural strength of prestressed concrete beams with tendons wrapped by plastic sheets", J. Mar. Sci. Technol., 21(1), 76-81.