References
- T. Yamamoto, K. Tsuboi, K. Nakai, H. Kumada, H. Sakurai, A. Matsumura, Boron neutron capture therapy for brain tumors, Transl. Cancer Res. 2 (2013) 80-86.
- International Atomic Energy Agency, Current Status of Neutron Capture Therapy, International Atomic Energy Agency, Austria, 2001.
- A. Khajeali, A.R. Farajollahi, R. Khodadadi, Y. Kasesaz, A. Khalili, Role of gel dosimeters in boron neutron capture therapy, Appl. Radiat. Isot 103 (2015) 72-81. https://doi.org/10.1016/j.apradiso.2015.05.017
- M.C. Hsiao, W.L. Chen, P.E. Tsai, C.K. Huang, Y.H. Liu, H.M. Liu, S.H. Jiang, A preliminary study on using the radiochromic film for 2D beam profile QC/QA at the THOR BNCT facility, Appl. Radiat. Isot 69 (2011) 1915-1917. https://doi.org/10.1016/j.apradiso.2011.04.007
- T. Schmitz, N. Bassler, M. Blaickner, M. Ziegner, M.C. Hsiao, Y.H. Liu, H. Koivunoro, I. Auterinen, T. Seren, P. Kotiluoto, H. Palmans, P. Sharpe, P. Langguth, G. Hampel, The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields, Med. Phys 42 (2015) 400.
- C. Aschan, M. Toivonen, S. Savolainen, T. Seppala, I. Auterinen, Epithermal neutron beam dosimetry with thermoluminescence dosemeters for boron neutron capture therapy, Radiat. Prot. Dosimetry 81 (1999) 47-56. https://doi.org/10.1093/oxfordjournals.rpd.a032569
- C. Baldock, Y. De Deene, S. Doran, G. Ibbott, A. Jirasek, M. Lepage, K.B. McAuley, M. Oldham, L.J. Schreiner, Polymer gel dosimetry, Phys. Med. Biol 55 (2010) R1-R63. https://doi.org/10.1088/0031-9155/55/5/R01
- G. Gambarini, S. Arrigoni, M. Bonardi, M.C. Cantone, D. deBartolo, S. Desiati, L. Facchielli, A.E. Sichirollo, A system for 3-D absorbed dose measurements with tissueequivalence for thermal neutrons, Nucl. Instrum. Methods Phys. Res. A 353 (1994) 406-410. https://doi.org/10.1016/0168-9002(94)91686-1
- G. Gambarini, C. Birattari, D. Monti, M.L. Fumagalli, A. Vai, P. Salvadori, L. Facchielli, A.E. Sichirollo, Fricke-infused agarose gel phantoms for NMR dosimetry in boron neutron capture therapy and proton therapy, Radiat. Prot. Dosimetry 70 (1997) 571-575. https://doi.org/10.1093/oxfordjournals.rpd.a032019
- G. Gambarini, S. Agosteo, M. Carrara, S. Gay, M. Mariani, L. Pirola, E. Vanossi, In-phantom dosimetry for BNCT with Fricke and normoxic-polymer gels, J. Phys. Conf. Ser 41 (2006) 275. https://doi.org/10.1088/1742-6596/41/1/029
- A.R. Farajollahi, D.E. Bonnett, D. Tattam, S. Green, The potential use of polymer gel dosimetry in boron neutron capture therapy,, Phys. Med. Biol. 45 (2000) N9. https://doi.org/10.1088/0031-9155/45/4/401
-
J. Uusi-Simola, S. Savolainen, A. Kangasmaki, S. Heikkinen, J. Perkio, U.A. Ramadan, T. Seppala, J. Karila, T. Seren, P. Kotiluoto, P. Sorvari, I. Auterinen, Study of the relative dose-response of BANG-3
$^{(R)}$ polymer gel dosimeters in epithermal neutron irradiation, Phys. Med. Biol 48 (2003) 2895. https://doi.org/10.1088/0031-9155/48/17/310 - A. Khajeali, A.R. Farajollahi, Y. Kasesaz, R. Khodadadi, A. Khalili, A. Naseri, Capability of NIPAM polymer gel in recording dose from the interaction of 10 B and thermal neutron in BNCT, Appl. Radiat. Isot 105 (2015) 257-263. https://doi.org/10.1016/j.apradiso.2015.08.028
- R.J. Senden, P.D. Jean, K.B. McAuley, L.J. Schreiner, Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose-response using different monomers, Phys. Med. Biol 51 (2006) 3301. https://doi.org/10.1088/0031-9155/51/14/001
- W.S. Snyder, M.R. Ford, G.G. Warner, H. Fisher Jr., Estimates of Absorbed Fractions for Monoenergetic Photon Sources Uniformly Distributed in Various Organs of a Heterogeneous Phantom, Oak Ridge National Lab., Tenn., 1969.
- E. Bavarnegin, H. Khalafi, A. Sadremomtaz, Y. Kasesaz, Construction of a head phantom for mixed neutron and gamma field dosimetry in TRR, Measurement 89 (2016) 145-150. https://doi.org/10.1016/j.measurement.2016.03.070
- I. Auterinen, T. Seren, K. Anttila, A. Kosunen, S. Savolainen, Measurement of free beam neutron spectra at eight BNCT facilities worldwide, Appl. Radiat. Isot 61 (2004) 1021-1026. https://doi.org/10.1016/j.apradiso.2004.05.035
- Y.-W. Liu, T. Huang, S. Jiang, H. Liu, Renovation of epithermal neutron beam for BNCT at THOR, Appl. Radiat. Isot 61 (2004) 1039-1043. https://doi.org/10.1016/j.apradiso.2004.05.042
- G. Ke, Z. Sun, F. Shen, T. Liu, Y. Li, Y. Zhou, The study of physics and thermal characteristics for in-hospital neutron irradiator (IHNI),, Appl. Radiat. Isot 67 (2009) S234-S237. https://doi.org/10.1016/j.apradiso.2009.03.117
- Y. Kasesaz, H. Khalafi, F. Rahmani, A. Ezati, M. Keyvani, A. Hossnirokh, M.A. Shamami, M. Monshizadeh, A feasibility study of the Tehran research reactor as a neutron source for BNCT, Appl. Radiat. Isot 90 (2014) 132-137. https://doi.org/10.1016/j.apradiso.2014.03.028
- Y. Kasesaz, H. Khalafi, F. Rahmani, Design of an epithermal neutron beam for BNCT in thermal column of Tehran research reactor, Ann. Nucl. Energy 68 (2014) 234-238. https://doi.org/10.1016/j.anucene.2014.01.014
- Y. Kasesaz, H. Khalafi, F. Rahmani, A. Ezzati, M. Keyvani, A. Hossnirokh, M.A. Shamami, S. Amini, Design and construction of a thermal neutron beam for BNCT at Tehran Research Reactor, Appl. Radiat. Isot 94 (2014) 149-151. https://doi.org/10.1016/j.apradiso.2014.08.004
- Y. Kasesaz, E. Bavarnegin, M. Golshanian, A. Khajeali, H. Jarahi, S. Mirvakili, H. Khalafi, BNCT project at Tehran Research Reactor: current and prospective plans, Prog. Nucl. Energy 91 (2016) 107-115. https://doi.org/10.1016/j.pnucene.2016.04.010
- F. Pak, A. Farajollahi, A. Movafaghi, A. Naseri, Influencing factors on reproducibility and stability of MRI NIPAM polymer gel dosimeter, BioImpacts 3 (2013) 163.
- A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi, The basic radiation properties of the N-isopropylacrylamide based polymer gel dosimeter, Int. J. Radiat. Res 12 (2014) 347-354.
- A.R. Farajollahi, D.E. Bonnett, D. Tattam, S. Green, The potential use of polymer gel dosimetry in boron neutron capture therapy, Phys. Med. Biol 45 (2000) N9-N14. https://doi.org/10.1088/0031-9155/45/4/401
- G. Gambarini, A. Negri, V. Regazzoni, D. Magni, R. Nolli, F. Campi, J. Burian, M. Marek, V. Klupak, L. Viererbl, Methods for dose measurements in small phantoms irradiated at BNCT epithermal column, Appl. Radiat. Isot 88 (2014) 118-124. https://doi.org/10.1016/j.apradiso.2013.11.093
- E. Vanossi, M. Carrara, G. Gambarini, A. Negri, M. Mariani, In-phantom dose imaging with polymer gel layer dosimeters, Appl. Radiat. Isot 67 (2009) S195-S198. https://doi.org/10.1016/j.apradiso.2009.03.048
- G. Gambarini, C. Birattari, C. Colombi, L. Pirola, G. Rosi, Fricke gel dosimetry in boron neutron capture therapy, Radiat. Prot. Dosimetry 101 (2002) 419-422. https://doi.org/10.1093/oxfordjournals.rpd.a006015
- J. Uusi-Simola, S. Heikkinen, P. Kotiluoto, T. Seren, T. Seppala, I. Auterinen, S. Savolainen, MAGIC polymer gel for dosimetric verification in boron neutron capture therapy, J. Appl. Clin. Med. Phys 8 (2007) 114-123.
Cited by
- Modeling of neutron diffractometry facility of Tehran Research Reactor using Vitess 3.3a and MCNPX codes vol.50, pp.1, 2017, https://doi.org/10.1016/j.net.2017.10.004
- Synthesis and characterization of the POSS/PCL-graphene oxide composites; the effects of gamma-radiation on its thermal properties and molecular weight vol.6, pp.12, 2019, https://doi.org/10.1088/2053-1591/ab59b1
- Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry vol.7, pp.2, 2021, https://doi.org/10.3390/gels7020074