DOI QR코드

DOI QR Code

FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System

소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서

  • Ahmad, Sheikh Faisal (Institute of Advanced Convergence Technology, Kyungpook National University) ;
  • Kim, Hyun Deok (School of Electronics Engineering, Kyungpook National Unversity)
  • Received : 2017.05.31
  • Accepted : 2017.07.21
  • Published : 2017.07.31

Abstract

A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.

Keywords

References

  1. P. Mansfield, "Imaging by nuclear magnetic resonance", J. Phys. E: Sci. Instrum., Vol. 21, No. 1, pp. 18-30, 1988. https://doi.org/10.1088/0022-3735/21/1/002
  2. N. Blow, "How to get ahead in imaging", Nature, Vol. 458, pp. 925-928, 2009. https://doi.org/10.1038/458925a
  3. R. Gruetter, S. A. Weisdorf, V. Rajanayagan, M. Terpstra, H. Merkle, C. L. Truwit, M. Garwood, S. L. Nyberg, and K. Ugurbil, "Resolution improvements in in vivo 1H NMR spectra with increased magnetic field strength", J. Magn. Reson., Vol. 135, No. 1, pp. 260-264, 1998. https://doi.org/10.1006/jmre.1998.1542
  4. J. C. Chatham, and S. J. Blackband, "Nuclear magnetic resonance spectroscopy and imaging in animal research", ILAR J., Vol. 42, No. 3, pp. 189-208, 2001. https://doi.org/10.1093/ilar.42.3.189
  5. R. A. Komoroski, "Nonmedical applications of NMR imaging", Anal. Chem., Vol. 65, No. 24, pp. 1068A-1077A, 1993. https://doi.org/10.1021/ac00072a714
  6. D. I. Hoult, and P. L. Lauterbur, "The sensitivity of the zeugmatographic experiment involving human samples", J. Magn. Reson., Vol. 34, No. 2, pp. 425-433, 1979. https://doi.org/10.1016/0022-2364(79)90019-2
  7. F. D. Doty, G. Entzminger, J. Kulkarni, K. Pamarthy, and J. P. Staab, "Radio frequency coil technology for small animal MRI", NMR Biomed., Vol. 20, No. 3, pp. 304-325, 2007. https://doi.org/10.1002/nbm.1149
  8. A. Haase, F. Odoj, M. V. Kienlin, J. Warnking, F. Fidler, A. Weisser, M. Nittka, E. Rommel, T. Lanz, B. Kalusche, and M. Griswold, "NMR probeheads for in vivo applications", Concepts Magn. Reson., Vol. 12, No. 6, pp. 361-388, 2000. https://doi.org/10.1002/1099-0534(2000)12:6<361::AID-CMR1>3.0.CO;2-L
  9. J. T. Vaughan, G. Adriany, C. J. Snyder, J. Tian, T. Thiel, L. Bolinger, H. Liu, L. DelaBarre, and K. Ugurbil, "Efficient high-frequency body coil for high-field MRI", Magn. Reson. Med., Vol. 52, No. 4, pp. 851-859, 2004. https://doi.org/10.1002/mrm.20177
  10. B. Keil, G. C. Wiggins, C. Triantafyllou, L. L. Wald, F. M. Meise, L. M. Schreiber, K. J. Klose, and J. T. Heverhagen, "A 20-channel receive-only mouse array coil for a 3T clinical MRI system", Magn. Reson. Med., Vol. 66, No. 2, pp. 584-595, 2011.
  11. C. E. Hayes, W. A. Eldestine, J. F. Schenck, O. M. Mueller, and M. Eash, "An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5T", J. Magn. Reson., Vol. 63, No. 3, pp. 622-628, 1985. https://doi.org/10.1016/0022-2364(85)90257-4
  12. C. E. Hayes, "The development of the birdcage resonator: a historical perspective", NMR Biomed., Vol. 22, No. 9, pp. 908-918, 2009. https://doi.org/10.1002/nbm.1431
  13. M. C. Leifer, "Resonant modes of the birdcage coil", J. Magn. Reson., Vol. 124, No. 1, pp. 51-60, 1997. https://doi.org/10.1006/jmre.1996.7488
  14. http://www.ansys.com/products/electronics/ansys-hfss (retrieved on May. 6, 2017).
  15. H. W. Son, S. F. Ahmad, J. Y. Choi, H. D. Kim, and Y. K. Cho, "Effect of distributed capacitance on the performance of birdcage type RF coil for 1H MRI", Proc. of Int'l Symp. on Antenna Propagation, FrP2-58, Jeju, South Korea, 2011.