DOI QR코드

DOI QR Code

Simulation Analysis of Thermal Insulation Performance of PCM for Mitigating Urban Heat Island Effect

도시열섬현상 저감을 위한 PCM(Phase Change Material)의 단열성능 시뮬레이션 분석

  • Received : 2016.12.16
  • Accepted : 2017.05.22
  • Published : 2017.06.30

Abstract

This study aimed to analyze the Thermal Insulation Performance of the PCM Cool Roof System, which is being developed for mitigating the Urban Heat Island Effect. We compared the performance of common insulation material versus that of PCM, both applied on a standard roof model. We found that PCM had less cooling energy consumption compared to common insulation, whereas common insulation had less heating energy consumption. The annual total energy consumption was found to be lower when using PCM. Therefore, we conclude that the PCM Cool Roof System has insulating capacity comparable to that of common insulation.

Keywords

Acknowledgement

Supported by : 국토교통부

References

  1. Bang, S. K. (2016). A Scaled Model Test of Thermal Performance using PCM for Mitigating Urban Heat Island Effect, master's degree thesis, Chung-Ang University Graduate School, Department of Architectural Engineering, Building Equipment and Energy Major
  2. Jeong, S. K., Jeon, J. S., Seo, J. K., & Kim, S. M. (2011). Consideration for Application of Phase Change Material (PCM) for Building Energy Saving, Journal of Korean Institute of Architectural Sustainable Environment and Building System, 5(1), 7-15
  3. Kim, J. H. (1996). A study on the thermal performance evaluation of the exterior wall for the insulating methods in building = focused on the usage of building, master's degree thesis, Suwon University Graduate School, Department of Architectural Engineering
  4. Lei, J., Yang, J., & Yang, E. H. (2016). Energy performance of building envelopes integrated with phase change materials for cooling load reduction in tropical Singapore, Applied Energy, 162, 207-217 https://doi.org/10.1016/j.apenergy.2015.10.031
  5. Park, S. J., & Jeong, H. (2013). A study on Design Current State and Optimization of Envelope Composition of Multi-Family Housing, Journal of Architectural Institute of Korea, 15(2), 109-118
  6. Shin, C. S. (2017). An Evaluation of Thermal Performance of the PCM Cool Roof System for Mitigation of Heat Island Effect, master's degree thesis, Chung-Ang University Graduate School, Department of Architectural Engineering, Building Equipment and Energy Major
  7. Seo, D. H., Noh, B. I., & Ihm, P. C. (2014). A Research on Prototype Apartment House Definition for Detailed Building Energy Simulation, Journal of Architectural Institute of Korea, 16(6), 285-296