Abstract

This paper provides an economic analysis of a new geothermal heat pump system that reuses condenser waste heat from a Ground Source Heat Pump ($GSHP_{ch}$) to provide energy for a hot water Ground Source heat pump ($GSHP_{hw}$). After conducting feasibility tests using GLD and TRNSYS simulations, the proposed system was effectively installed and thoroughly tested. We observe that 1) the Coefficient of Performance (COP) of the $GSHP_{hw}$ and the $GSHP_{ch}$ during cooling mode improves by up to 62% and 7%, respectively; 2) the number of bore holes can be reduced by two; and 3) the hot water supply temperature of the $GSHP_{hw}$ increases by up to $60^{\circ}C$. We further conclude that 1) the reduction of two bore holes can save approximately ten million Won from the initial cost investment; and 2) the increased COP of the $GSHP_{hw}$ can save approximately one million Won in annual electricity costs.

Keywords

References

  1. Shin, J. S. and Kim, S, H., 2016, Second Stage Heating-type Geothermal Heat System using Geothermal Energy, Proceedings of 2016 Summer Annual Conference of the Korea Society of Geothermal Energy Engineers, pp. 71-74.
  2. Song, J., Jung, H., Park, J. W., Kang, H., and Kim, Y., 2013, Numerical Study of the Performance Characteristics of a Cascade Heat Pump Water Heater at Low Ambient Temperatures, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 5, pp. 225-232. https://doi.org/10.6110/KJACR.2013.25.5.225
  3. Son, C., 2009, Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Carbon Dioxide (R744) and Propane (R290), Transactions of the Korean hydrogen and new energy society, Vol. 20, No. 6, pp. 526-533.
  4. Satyananda, T., Jibanananda, J., Dillip, K. P., and Manmatha, K. R., 2014, Thermodynamic Analysis of a Cascade Refrigeration System Based On Carbon Dioxide and Ammonia, Int. Journal of Engineering Research and Applications, Vol. 4, No. 7, pp. 24-29.
  5. Gajendrasinh, G. P. and Kapadia, Dr. R. G., 2015, Thermodynamic Analysis of Cascade Refrigeration System using a Natural Refrigerants for Supermarket Application, Int. Journal of Innovative Research in Science, Engineering and Technology, Vol. 4, pp. 1839-1846.
  6. Park, J. I. and Park, K, S., 2013, Study on Capacity Alteration of Geothermal Heat Exchanger by Changing Design Condition, Transactions of the Korea Society of Geothermal Energy Engineers, Vol. 9, No. 4, pp. 9-14. https://doi.org/10.17664/ksgee.2013.9.4.009
  7. Kang, E. K., 2014, Dynamic Simulation of Heat Pump Gravel Charged SCW, Seoul National University of Science & Technology, Korea.