DOI QR코드

DOI QR Code

Development and performance verification of induced drainage method for leakage treatment in existing underground structures

운영중인 지하구조물 누수처리를 위한 유도배수공법 개발 및 성능 검증

  • Kim, Dong-Gyou (Geotechnical Engineering Research Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Yim, Min-Jin (Geotechnical Engineering Research Institute, Korea Institute of Civil Engineering and Building Technology)
  • 김동규 (한국건설기술연구원 지반연구소) ;
  • 임민진 (한국건설기술연구원 지반연구소)
  • Received : 2017.05.02
  • Accepted : 2017.05.24
  • Published : 2017.05.31

Abstract

In this study, drainage systems were proposed to drain the leakage of groundwater in the existing underground concrete structures. The system consists of drainage board, wire mesh, fixed nail, and mortar with mineral. In order to increase constructability, the drainage board and wire mesh were attached on the surface of cement concrete using the air nailer and fixed nail. The mortar with 30% of blast furnace slag was sprayed on the drainage board and wire mesh using the spray mortar equipment. The field test construction was carried out in a conventional concrete lining tunnel and concrete retaining wall for performance verification of the drainage system in the field. There was no problem with performance degradation in the drainage system for three years after construction. The bond strength tests were performed on the sprayed mortar at 14 days and about 3 years after field test construction. In case of attaching the wire mesh on the drainage board, the bond strengths of the sprayed mortar were 1.04 MPa at 14 days and 1.46 MPa about 3 years. In case of the drainage board without the wire mesh, the bond strengths of the sprayed mortar were 1.13 MPa at 14 days and 0.89 MPa, less than 1 MPa of bond strength criteria, about 3 years.

본 연구에서는 지하 콘크리트 구조물 내로 누수된 지하수를 유도하여 배수하는 유도배수공법을 제시하였다. 유도배수공법은 유도배수판, 철망, 고정핀, 광물질 혼입 모르타르로 구성된다. 시공성 향상을 위하여 유도배수판 및 철망은 공압타카와 고정핀를 사용하여 콘크리트 표면에 부착하였다. 고로슬래그미분말을 30% 혼입한 모르타르는 뿜어 붙임 모르타르 장비를 사용하여 유도배수판 및 철망 표면에 타설하였다. 유도배수공법의 현장 시공성 및 성능 검증을 위하여 재래식 콘크리트라이닝 터널과 콘크리트 옹벽에서 시험시공을 수행하였다. 시험시공 완료 3년 후 유도배수공법은 성능저하의 문제점이 없는 것으로 판단되었다. 재령 14일과 3년에 뿜어 붙임 모르타르의 부착력 실험을 수행하였다. 유도배수판 표면에 철망을 적용한 경우 뿜어 붙인 모르타르의 부착력은 재령 14일에 1.04 MPa, 재령 3년에 1.46 MPa로 측정되었다. 철망을 적용하지 않은 경우의 부착력은 재령 14일에 1.13 MPa로 측정되었지만, 재령 3년에는 0.89 MPa로 기준 부착력 1 MPa보다 낮게 측정되었다.

Keywords

References

  1. Choo, J.H., Park, S.W., Kim, H.T., Jee, K.H., Yoon, T.G. (2011), "Analysis and cause of occurrence of lining cracks on NATM tunnel based on the precise inspection for safety and diagnosis - Part I", Journal of Korean Tunnelling and Underground Space Association, Vol. 13, No. 3, pp. 199-214.
  2. Kim, D.G., Jung, H.S., Choi, Y.N. (2008), Development of Safety Maintenance and Disaster Prevention Technology(V), KICT 2008-038, Korea Institute of Construction Technology.
  3. Kim, D.G., Baek, Y., Shin, H.Y., Jung, H.S. (2009), Development of Safety Maintenance and Disaster Prevention Technology(VI), KICT 2009-069, Korea Institute of Construction Technology.
  4. Kim, D.G., Jung, H.S., Bae, G.J., Shin, H.S. (2009), "Characterization of deterioration of concrete lining in tunnel structures", Journal of Korean Tunnelling and Underground Space Association, Vol. 11, No. 4, pp. 387-391.
  5. Kim, Y.S., Shin, H.C., Kim, Y.G. (2012), "Waterproofing method and new technologies for construction structure", Magazine of Korea Concrete Institute, Vol. 24, No. 4, pp. 23-28. https://doi.org/10.22636/MKCI.2012.24.4.23
  6. Kim, H.T., Han, M.Y., Son, E.J., Han, R.H., Jung, J.M. (2008), 'A study on the state of the art on the construction and the new technology of the underground structure (underpass, underground passageways)", Proceedings of the Korea Concrete Institute, Vol. 20, No. 2, pp. 891-894.
  7. Korea Rail Network Authority, (2016), http://kr.or.kr/sub/info.do?m=05020202.
  8. Kwon, K.J., Oh, S.G. (2008), "A performance test method of waterproofing system to evaluate the responsiveness to the movement of box culvert structure for underground electronic power facility", Magazine of Korea Concrete Institute, Vol. 20, No. 4, pp. 57-62. https://doi.org/10.22636/MKCI.2008.20.4.57
  9. Lee, Y.S., Park, S.W., Whang, I.B., Shin, Y.S., Kim, S.G. (2009), "Analysis of cause and deterioration about using 3-Arch tunnel", Journal of Korean Tunnelling and Underground Space Association, Vol. 11, No. 1, pp. 97-105.
  10. Oh, S.G. (2005), Development of waterproofing method of ground structures applied to fully boned sheet(reverse tanking) and waterproofing concrete for crack safety, 04CCTI-C041008-02, Korea Agency for Infrastructure Technology Advancement.
  11. Ministry of Environment, (2012), Sewerage statistics.
  12. Mehta, P.K. (1993), "Concrete", Prentice Hall, pp. 126-176.
  13. Michael, T.K. (1993), Waterproofing the Building Envelope, McGraw-Hill.
  14. Ministry of Land, Infrastructure and Transport, (2016), Yearbook of road bridge and tunnel Statistics.
  15. Nevilie, A.M. (1995), "Properties of concrete", Fourth and Final Edition, Longman.