Single-phase Cascaded H-bridge Multilevel Active Power Filters in AC Electric Railway Systems

  • Wu, Liran (School of Electrical Engineering, Beijing Jiaotong University) ;
  • Wu, Mingli (School of Electrical Engineering, Beijing Jiaotong University)
  • 투고 : 2016.10.13
  • 심사 : 2017.02.13
  • 발행 : 2017.05.20

초록

The power quality of AC electric railways has become an issue worthy of more and more concern. Many active compensators based on power converters have been proposed, but with complex transformers or coupled branches. This paper presents a single-phase cascaded H-bridge multilevel active power filter (APF), which can directly connect to the 27.5-kV power supplies to deal with power quality problems. According to field measured data, the load characteristics are analyzed, and the system configuration and control system are designed based on the load characteristic analysis. Finally, simulation and experimental results verify the effectiveness of the proposed APF system, considering some problems such as the supply voltage fluctuations and transient inrush currents in AC electric railway systems.

키워드

참고문헌

  1. G. Lin, X. Yonghai, X. Xiaoning, J. Peisi, and Z. Yunyan, "Simulation model and harmonic analysis of SS6b electric locomotive based on PSCAD/EMTDC," in Proc. EPEC, pp.1-5, 2008
  2. P. Caramia, G. Carpinelli, P. Varilone, P. Verde, D. Gallo, and R. Langella, "High speed AC locomotives: harmonic and inter harmonic analysis at a vehicle test room," in Proc. IEEE Harmonics and Quality of Power, pp. 347-353, 2000.
  3. G. Lin, X. Yonghai, X. Xiaoning, L. Yingying, and J. Peisi, "Analysis of adverse effects on the public power grid brought by traction power supply system," in Proc. IEEE Elect. Power Energy Conference, pp. 1-7, 2008.
  4. S. Zeliang, X. Shaodeng, and L. Qunzhan, "Single-Phase Back-To-Back Converter for Active Power Balancing, Reactive Power Compensation, and Harmonic Filtering in Traction Power System," IEEE Trans. Power Electron., Vol. 26, No. 2, pp. 334-343, Feb. 2011. https://doi.org/10.1109/TPEL.2010.2060360
  5. P. C. Tan, P. C. Loh, and D. G. Holmes, "A robust multilevel hybrid compensation system for 25-kV electrified railway applications," IEEE Trans. Power Electron., Vol. 19, No. 4, pp. 1043-1052, Jul. 2004. https://doi.org/10.1109/TPEL.2004.830038
  6. Z. He, H. Hu, Y. Zhang, and S. Gao, "Harmonic resonance assessment to traction power-supply system considering train model in china high-speed railway," IEEE Trans. Power Del., Vol. 29, No. 4, pp. 1735-1743, Aug. 2014. https://doi.org/10.1109/TPWRD.2013.2284233
  7. Z. He, H. Haitao, and G. Shibin, "Passive Filter Design for China High-Speed Railway With Considering Harmonic Resonance and Characteristic Harmonics," IEEE Trans. Power Del., Vol. 30, No. 1, pp. 505-514, Feb. 2015. https://doi.org/10.1109/TPWRD.2014.2359010
  8. H. Junfei, L. Zhang, and S. J. Watkins, "Active power filtering by a flying-capacitor multilevel inverter with capacitor voltage balance," in Proc. IEEE International Industrial Electronics, pp. 2348-2352, 2008.
  9. K. M. Kwon, Y. S. Song, and J. Choi, "6MVA single-phase APF for high speed train line in Korea," in Proc. IEEE Power Engineering and Renewable Energy, pp.31-36, 2014.
  10. H. Park, J. Han, and J. Song, "Control Strategy for Shunt Active Power Filter Using Hybrid Multi-level Inverter in AC Electrified Railway Systems," IETE Journal of Research, Vol. 58, No. 6, pp.451-458, Jul. 2012. https://doi.org/10.4103/0377-2063.106738
  11. Z. Wang, J. Wang, J. Liu, J. Wang, and G. Li, "Harmonic suppression in electric traction system based on a single-phase hybrid active filter," in Proc. IET Sustainable Power Generation and Supply, pp.1-5, 2012.
  12. N. Y. Dai, K. W. Lao, M. C. Wong, and C. K. Wong, "Hybrid power quality conditioner for co-phase power supply system in electrified railway," IET Power Electronics, Vol. 5, No.7, pp.1084-1094, Aug. 2012. https://doi.org/10.1049/iet-pel.2011.0292
  13. B. Chen, C. Zhang, C. Tian, J. Wang, and J. Yuan, "A hybrid electrical magnetic power quality compensation system with minimum active compensation capacity for V/V cophase railway power supply system," IEEE Trans. Power Electron., Vol. 31, No. 6, pp.4159-4170, Sep. 2016. https://doi.org/10.1109/TPEL.2015.2477459
  14. R. Xu, Y. Yu, R. Yang, G. Wang, D. Xu, B. Li, and S. Sui "A novel control method for transformerless H-bridge cascaded STATCOM with star configuration," IEEE Trans. Power Electron., Vol. 30, No. 3, pp.1189-1202, Apr. 2015. https://doi.org/10.1109/TPEL.2014.2320251
  15. S. M. M. Gazafrudi, A. T. Langerudy, E. F. Fuchs, K. Al-Haddad, "Power quality issues in railway electrification: a comprehensive perspective," IEEE Trans. Ind. Electron., Vol. 62, No. 5, pp.3081-3090, Dec. 2015. https://doi.org/10.1109/TIE.2014.2386794
  16. GB/T14549 93, Quality electric energy supply Harmonics public supply network, Chinese Std, 1993.
  17. N. Zhou, J. Wang, Q. Wang, N. Wei, and X. Lou, "Capacity calculation of shunt active power filters for electric vehicle charging stations based on harmonic parameter estimation and analytical modeling," Energies, Vol. 7, No. 8, pp. 5425-5443, Aug. 2014. https://doi.org/10.3390/en7085425
  18. L. Qionglin, W. Bifang, and H. Yuhang, "Optimal compensation capacity design for active power filters in considering harmonics stochastic characteristics," Automation of Electric Power Systems(in Chinese), Vol. 31, No. 15, pp. 61-64 +93, Aug. 2007.
  19. S. Golestan, M. monfared, F. D. Freijedo, and J. M. Guerrero "Dynamics assessment of advanced single-phase pll structures," IEEE Trans. Ind. Electron., Vol. 60, No. 6, pp. 2167-2177, Jun. 2013. https://doi.org/10.1109/TIE.2012.2193863
  20. H. Li, K. Zhang, H. Zhao, S. Fan, and J. Xiong "Active power decoupling for high-power single-phase pwm rectifiers," IEEE Trans. Power Electron., Vol. 28, No. 3, pp.1308-1319, Jul. 2013. https://doi.org/10.1109/TPEL.2012.2208764
  21. W. Jianmin, Z. Guo, Z. Xiaomin, and T. Mengmeng, "Several methods to improve the accuracy of adaptive harmonic current detection for single-phase circuits," in Proc. ICEMI, pp.316-320, 2013.
  22. W. Li Ran and W. Mingli, "Detection method for single-phase random harmonic current without PLL," Applied Mechanics & Materials. Vol. 719-720, No. 5, pp.622-629, Jan. 2015. https://doi.org/10.4028/www.scientific.net/AMM.719-720.622
  23. R. Teodorescu, F. Blaabjerg, M. Loserre, and P. C. Loh, "Proportional-resonant controllers and filters for grid-connected voltage-source converters," IEE Proceedings-Electric Power Applications, Vol. 153, No.5, pp.750-762, Sep. 2006. https://doi.org/10.1049/ip-epa:20060008
  24. R. Pena-Alzola, M. A. Bianchi, and M. Ordonez, "Control design of a PFC with harmonic mitigation function for small hybrid AC/DC buildings," IEEE Trans. Power Electron., Vol. 31, No. 9, pp. 6607-6620, Nov. 2016. https://doi.org/10.1109/TPEL.2015.2499163
  25. W. Na, M. Yuanpeng, "Harmonic current elimination for rectifiers based on N Times notch filter and PR controller," Electric Drive for Locomotives (in Chinese), Vol.2, No. 1, pp. 61-66, Mar. 2015.
  26. X. Hailiang, L. Zili, H. Yikang, "Key points of proportionresonant controller applied for pwm converters," Automation of Electric Power Systems (in Chinese), Vol.18, No.1, Sep. 2015.
  27. Y. Xingwu, J. Jiang, and S. Liu, "A novel design approach of DC voltage balancing controller for cascaded h-bridge converter-based STATCOM," in Proc. IEEE Power Electronics and Motion Control, pp.2359-2364, 2009.
  28. X. She, A. Q. Huang, T. Zhao, and G. Wang, "Coupling effect reduction of a voltage-balancing controller in single-phase cascaded multilevel converters," IEEE Trans. Power Electron., Vol. 27, No. 8, pp. 3530-3543, Aug. 2012. https://doi.org/10.1109/TPEL.2012.2186615
  29. M. Morteza, G. Farivar, H. Iman-Eini, and S. M. Shekarabi, "A voltage balancing strategy with extended operating region for cascaded H-bridge converters," IEEE Trans. Power Electron., Vol. 29, No,9, pp.5044-5053, Sep. 2014. https://doi.org/10.1109/TPEL.2013.2286270
  30. Z. Liu, B. Liu, S. Duan, and Y. Kang, "A novel DC capacitor voltage balance control method for cascade multilevel STATCOM," IEEE Trans. Power Electron., Vol. 27, No.1, pp. 14-27, Jan. 2012. https://doi.org/10.1109/TPEL.2010.2050337