Suggestion for the Simplified Pullout test of Normal Concrete Strength

보통 콘크리트강도형 간이 인발시험법에 대한 제안

  • Received : 2016.11.03
  • Accepted : 2017.03.13
  • Published : 2017.04.30

Abstract

The pullout test certified by the American Society for Testing and Materials(ASTM) is known to be more reliable for estimating concrete strength under construction of concrete structures than other nondestructive testing(NDT) methods such as rebound number, penetration resistance, break-off, and ultrasonic pulse velocity. However, existing equipment needed for the pullout test, known as Lok test or Capo test, require several complex installation steps and expensive loading systems including load cell. We propose a simplified pullout test composed of a break-off type bolt, a standard bolt with a groove on the shaft, as an insert, an insert nut, and a pullout instrument without load cell. This simplified pullout test would be more beneficial due to its low cost, simplicity and convenience. To verify the advantages of the simplified pullout test, three wall specimens were tested with two types of concrete strength, 15MPa and 24MPa, using the Lok test, a general pullout test including load cell, and a simplified pullout test. It was found that the pullout force was very similar in comparison with compressive strength. Therefore, it was verified that the simplified pullout test can be used to replace the Lok test. The prediction equation of groove diameter with the concrete strength was derived as y=6.01x-17.17(y=concrete strength, x=the groove diameter of break-off bolt) through regression analysis. An allowable error can be easily maintained within the specified value if appropriate safety factors are studied and added to the prediction equation.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. ASTM. (2006). Standard Test Method for Pullout Strength of Hardened Concrete (ASTM C 900-06), 10 ASTM International, West Conshohocken, PA.
  2. ACI Committee 228. (2004). In-place methods to estimate concrete strength, American Concrete Institute, 6-9.
  3. Bickley, J.A. (1982). The Variability of Pullout Tests and In-Place Concrete, Concrete International.
  4. Bocca, P. (1984). The application of pull-out test to high strength concrete estimation, Materials and Structures, 17(3), 211-216.
  5. Brencich, A. (2015). A post-installed insert for pull-out tests on concrete up to 70 MPa, Construction and Building Materials, 95, 788-801. https://doi.org/10.1016/j.conbuildmat.2015.07.055
  6. Claus, GP., & Ervin, P. (1992). Pull-out testing by LOK-test and CAP-test, Dansk Betoninstitut A/S, 31-38.
  7. Kim, G., Lee, S., Kang, S., Kim, J., & Kim, K. (2007). Evaluation of in-situ concrete strength with pull-out testing at the early ages, Proceedings of the Korea Concrete Institute, 1087-1090.
  8. Ko, H., & Lee, J. (2006). Prediction of Concrete Strength with New Approach of Pullout Test, Journal of Architectural Institute of Korea, 22(8), 93-100.
  9. Ko, H. (2008). Evaluation for High Strength Concrete using Pullout Test, Journal of the Korea Institute of Building Construction, 8(3), 85-91. https://doi.org/10.5345/JKIC.2008.8.3.085
  10. Ko, H., Lee, G., & Won, J. (2011). Development of Post-installable Pullout Bolts and a Loading Device for Evaluating Concrete Strength, Journal of the Korea Institute of Building Construction, 11(3), 229-237. https://doi.org/10.5345/JKIC.2011.06.3.229
  11. Kierkegaard-Hansen, P. (1975). Lok-Strength, Stockholm, Nordisk Betong, V.19, No.2, 9-11.
  12. Komatu, Y., Kondo, G., & Morita, S. (1986). Variability of in-place Concrete Strength Evaluated by Pullout Test, Proc. JIA, No.1068.
  13. Krenchel, H. (1982). Lok-Strength and Capo-Strength of concrete, ABK publication, Serie I, No.71, Structural Research Laboratory, Technical University of Denmark.
  14. Lee, G., Ko, H., & Won, J. (2013). Effectiveness of a simplified Pullout Test using a Post-Installable Break-off Bolt, Research in Nondestructive Evaluation, Taylor & Francis, 24(1), 1-17. https://doi.org/10.1080/09349847.2012.675117
  15. Latte Bovio, F., Latte Bovio, G., Brencich, A., Cassini, G., Pera, D., & Riotto, G. (2014). A New Pull-out Technique for In-Place Estimation of Concrete Compressive Strength, Advances in Materials Science and Engineering.
  16. Leslie, J., & Cheesman, W.J. (1949). An Ultrasonic Method of Studying deteriorationand Cracking in Concrete Structures, ACI Journal, No.46-2.
  17. Malhotra, V.M.,. & Carette, G. (1980). Comparison of Pullout Strength of Concrete with Compressive Strength of Cylinders and Cores, Pulse, Velocity, and Rebound Number, ACI JOURNAL, 161-170.
  18. Ottosen, N.S. (1981). Non-linear Finite Element Analysis of Pull-out Test, Journal of Structural Division, ASCE, Vol.107, No.ST4.
  19. Richards, O. (1977). Pullout Strength of Concrete, Reproducibility and Accuracy of Mechanical Tests, STP-626, ASTM, Philadelphia, 32-40.
  20. Stone, W.C., Carino, N.J., & Reeve, C.P. (1986). Statistical Methods for In-Place Strength Predictions by the Pullout Test, ACI Journal, Proc. V.83, No.5, 745-756.
  21. Stone, W.C., & Reeve, C.P. (1986). New statistical method for prediction of concrete strength from in-place tests. Cement, Concrete, and Aggregates, 8(1), 3-12. https://doi.org/10.1520/CCA10048J