DOI QR코드

DOI QR Code

Development of Optical Fiber Glucose and Lactate Biosensors for Bioprocess Monitoring

생물공정 모니터링을 위한 광섬유 포도당 및 젖산 센서의 개발

  • Jung, Chang Hwan (School of Chemical Engineering, Research Center for Biophotonics, Chonnam National University) ;
  • Sohn, Ok-Jae (School of Chemical Engineering, Research Center for Biophotonics, Chonnam National University) ;
  • Rhee, Jong Il (School of Chemical Engineering, Research Center for Biophotonics, Chonnam National University)
  • 정창환 (전남대학교 공과대학 화학공학부) ;
  • 손옥재 (전남대학교 공과대학 화학공학부) ;
  • 이종일 (전남대학교 공과대학 화학공학부)
  • Received : 2017.01.23
  • Accepted : 2017.03.23
  • Published : 2017.03.31

Abstract

In this work the optical fiber glucose and lactate biosensors were developed by using fluorescent dye and enzyme immobilized on the end tip of an optical fiber. 3-Glycidyloxypropyl)methyldiethoxysilane (GPTMS), (3-Aminopropyl) trimethoxysilane (APTMS) and Methyltrimethoxysilane (MTMS) were used to immobilize glucose oxidase (GOD), lactate oxidase (LOD) and ruthenium(II) complex (tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II), $Ru(dpp)_3^{2+}$) as oxygen sensitive fluorescent dye. MTMS sol-gel was an excellent supporting material for the immobilization of $Ru(dpp)_3^{2+}$, GOD, and LOD on the optical fiber. Storage stability of the optical fiber glucose sensor was kept constant over 20 days, while the optical fiber lactate sensor had constant storage stability over 17 days. The optical fiber glucose and lactate biosensors also maintained good operational stability for 20 hours and 14 hours, respectively. The activities of the immobilized enzymes were most excellent at pH 7 and at $25^{\circ}C$. On-line monitoring of glucose and lactate in a simulated process was performed with the optical fiber glucose and lactate biosensors. On-line monitoring results were agreed with those of off-line data measured with high performance liquid chromatography (HPLC).

Keywords

References

  1. Muller, C., B. Hitzmann, F. Schubert, and T. Scheper (1997) Optical chemo-and biosensors for use in clinical applications. Sensors and Actuators B: Chemical 240: 71-77.
  2. Biechele, P., C. Busse, D. Solle, T. Scheper, and K. Reardon (2015) Sensor systems for bioprocess monitoring. Eng. Life Sci. 15: 469-488. https://doi.org/10.1002/elsc.201500014
  3. Rosenzweig, Z. and M. A. Wittenzellner (1990) The CO + $NH_3$ coadsorption over Re(0001) studied by optical second harmonic generation. Surf. Sci. 240: 583-590. https://doi.org/10.1016/0039-6028(90)90721-J
  4. Healey, B. G., L. Li, and D. R. Walt (1997) Multianalyte biosensors on optical imaging bundles. Biosens. Bioelectron. 12: 521-529. https://doi.org/10.1016/S0956-5663(97)00009-2
  5. Scheper, T., C. Muller, K. D. Anders, F. Eberhardt, F. Plotz, C. Schelp, O. Thordsen, and K. Schugerl (1994) Optical sensors for biotechnological applications. Biosens. Bioelectron. 9: 73-82. https://doi.org/10.1016/0956-5663(94)80017-0
  6. Alen, P., K. Hans, S. Lukas, T. R. Pieber, and K. Ingo (2006) Fiberoptic flow-through sensor for online monitoring of glucose. Analy. Bioanaly. Chem. 386: 1293-1302. https://doi.org/10.1007/s00216-006-0782-x
  7. Li, L., and D. R. Walt (1995) Dual-analyte fiber-optic sensor for the simultaneous and continuous measurement of glucose and oxygen. Anal. Chem. 67: 3746-3752. https://doi.org/10.1021/ac00116a021
  8. Healey, B. G. and D. R. Walt (1995) Improved fiber-optic chemical sensor for penicillin. Anal. Chem. 67: 4471-4476. https://doi.org/10.1021/ac00120a007
  9. Alen, R., K. Hans, K. Ingo, and S. Lukas (2007) Miniaturized fiberoptic hybrid sensor for continuous glucose monitoring in subcutaneous tissue. Sens. Actuators B 122: 60-68. https://doi.org/10.1016/j.snb.2006.05.010
  10. Sergei, G. I. G., A. F. Jane, and R. W. David (2001) A fiber-optic lactate sensor based on bacterial cytoplasmic membranes. Biosens. Bioelectron. 16: 109-113. https://doi.org/10.1016/S0956-5663(00)00144-5
  11. Stephen, R. D., B. Y. Jeffrey, E. K. Gamal, A. A. Alan, M. B. Douglas, and A. K. Margaret (1995) Application of a novel fiber-optic biosensor in situ to investigate the metabolic effect of lactate infusion. Neuropsychopharmacology 4: 12.
  12. Christophe, A. M. and J. B. Loic (1999) Luminol eletrochemiluminescence- based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples. Analytica Chimica Acta 381: 1-10. https://doi.org/10.1016/S0003-2670(98)00703-X
  13. Sohn, O. J. and J. I. Rhee (2006) Fiber-optic biosensor for analysis of glucose and lactate in blood samples. J. Korean Sens. Soc. 15: 28-33.
  14. Park, H. K., W. S. Whang, and I. H. Kim (2001) Purification study of glucose oxidase from aspergillus niger. Korean Chem. Eng. Res. 39: 512-516.
  15. Sohn, O. J. (2004) Development of monitoring technology for lactate, succinate, and fumatate in biological processes. M.S. Thesis. Chonnam National University, Gwangju, Korea.
  16. Kim, J. H., D. H. Lee, T. J. Kim, and B. S. No (1998) Development of biosensor for simultaneous determination of glucose, lactic acid and ethanol. Korean J. Food Sci. Technol. 30: 22-34.
  17. Romdhane, I. B., Z. B. Romdhane, A. Gargouri, and H. Belghith (2011) Esterification activity and stability of Talaromces thermophilus lipase immobilized onto chitosan. J. Mol. Catal. B-Enzym. 68: 230-239. https://doi.org/10.1016/j.molcatb.2010.11.010