References
- Muller, C., B. Hitzmann, F. Schubert, and T. Scheper (1997) Optical chemo-and biosensors for use in clinical applications. Sensors and Actuators B: Chemical 240: 71-77.
- Biechele, P., C. Busse, D. Solle, T. Scheper, and K. Reardon (2015) Sensor systems for bioprocess monitoring. Eng. Life Sci. 15: 469-488. https://doi.org/10.1002/elsc.201500014
-
Rosenzweig, Z. and M. A. Wittenzellner (1990) The CO +
$NH_3$ coadsorption over Re(0001) studied by optical second harmonic generation. Surf. Sci. 240: 583-590. https://doi.org/10.1016/0039-6028(90)90721-J - Healey, B. G., L. Li, and D. R. Walt (1997) Multianalyte biosensors on optical imaging bundles. Biosens. Bioelectron. 12: 521-529. https://doi.org/10.1016/S0956-5663(97)00009-2
- Scheper, T., C. Muller, K. D. Anders, F. Eberhardt, F. Plotz, C. Schelp, O. Thordsen, and K. Schugerl (1994) Optical sensors for biotechnological applications. Biosens. Bioelectron. 9: 73-82. https://doi.org/10.1016/0956-5663(94)80017-0
- Alen, P., K. Hans, S. Lukas, T. R. Pieber, and K. Ingo (2006) Fiberoptic flow-through sensor for online monitoring of glucose. Analy. Bioanaly. Chem. 386: 1293-1302. https://doi.org/10.1007/s00216-006-0782-x
- Li, L., and D. R. Walt (1995) Dual-analyte fiber-optic sensor for the simultaneous and continuous measurement of glucose and oxygen. Anal. Chem. 67: 3746-3752. https://doi.org/10.1021/ac00116a021
- Healey, B. G. and D. R. Walt (1995) Improved fiber-optic chemical sensor for penicillin. Anal. Chem. 67: 4471-4476. https://doi.org/10.1021/ac00120a007
- Alen, R., K. Hans, K. Ingo, and S. Lukas (2007) Miniaturized fiberoptic hybrid sensor for continuous glucose monitoring in subcutaneous tissue. Sens. Actuators B 122: 60-68. https://doi.org/10.1016/j.snb.2006.05.010
- Sergei, G. I. G., A. F. Jane, and R. W. David (2001) A fiber-optic lactate sensor based on bacterial cytoplasmic membranes. Biosens. Bioelectron. 16: 109-113. https://doi.org/10.1016/S0956-5663(00)00144-5
- Stephen, R. D., B. Y. Jeffrey, E. K. Gamal, A. A. Alan, M. B. Douglas, and A. K. Margaret (1995) Application of a novel fiber-optic biosensor in situ to investigate the metabolic effect of lactate infusion. Neuropsychopharmacology 4: 12.
- Christophe, A. M. and J. B. Loic (1999) Luminol eletrochemiluminescence- based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples. Analytica Chimica Acta 381: 1-10. https://doi.org/10.1016/S0003-2670(98)00703-X
- Sohn, O. J. and J. I. Rhee (2006) Fiber-optic biosensor for analysis of glucose and lactate in blood samples. J. Korean Sens. Soc. 15: 28-33.
- Park, H. K., W. S. Whang, and I. H. Kim (2001) Purification study of glucose oxidase from aspergillus niger. Korean Chem. Eng. Res. 39: 512-516.
- Sohn, O. J. (2004) Development of monitoring technology for lactate, succinate, and fumatate in biological processes. M.S. Thesis. Chonnam National University, Gwangju, Korea.
- Kim, J. H., D. H. Lee, T. J. Kim, and B. S. No (1998) Development of biosensor for simultaneous determination of glucose, lactic acid and ethanol. Korean J. Food Sci. Technol. 30: 22-34.
- Romdhane, I. B., Z. B. Romdhane, A. Gargouri, and H. Belghith (2011) Esterification activity and stability of Talaromces thermophilus lipase immobilized onto chitosan. J. Mol. Catal. B-Enzym. 68: 230-239. https://doi.org/10.1016/j.molcatb.2010.11.010