DOI QR코드

DOI QR Code

배수지의 배수효율분석을 위한 추적자실험 및 전산유체해석

Tracer Experiment and Computational Fluid Dynamics Analysis for the Drainage Efficiency of a Reservoir

  • 조중연 (전주대학교 탄소융합공학과) ;
  • 고선호 (전주대학교 기계공학과) ;
  • 곽이구 (전주대학교 탄소융합공학과)
  • Cho, Jung-Yeon (School of Carbon Fusion Engineering, JeonJu Univ.) ;
  • Go, Sun-Ho (School of Mechanical Engineering, JeonJu Univ.) ;
  • Kwac, Lee-Ku (School of Carbon Fusion Engineering, JeonJu Univ.)
  • 투고 : 2017.01.04
  • 심사 : 2017.02.02
  • 발행 : 2017.04.30

초록

During the water treatment process for household water supply, a reservoir is the last place the water is stored before being supplied to users, and the duration of the water's stay is an important factor that affects its safety. This may cause the concentration of the residual chlorine disinfectant to increase and thus lower the water's quality. The concentration and discharge efficiency of residual chlorine must be verified and managed, because these are key factors that affect the reservoir's performance. Because the actual verification test for analyzing the efficiency of a reservoir and the disinfectant's dilution capacity is difficult, simulations are generally conducted using the computational fluid analysis method. However, the simulation results require validation with experiments. The error and drainage efficiency were analyzed in this study by comparing and analyzing the actual tracer test and simulation so that the actual test for a hexagonal drainage can be replaced by the computational fluid analysis method. Based on the results of the efficiency analysis, the hexagonal reservoir was found to be appropriate, and the simulation's reliability was verified with a tracer test.

키워드

과제정보

연구 과제 주관 기관 : 한국연구재단

참고문헌

  1. Kim, H. K., "An Optimum Management Method of Residual Chlorine in Water Supply System," A Thesis for a Master, University of Seoul, Republic of Korea, 2016.
  2. Jang, H. Y., "A Study on the Introduction of Water Safety Plan for the Water Distribution Network Ensure Safety," A Thesis for a Master, University of Seoul, Republic of Korea, 2015.
  3. Hyun, J. H., Kim, Y. M., Kim, Y. S., "Study of Estimating Disinfection Efficiency(CT value) and Optimizing Chlorine Dosage by Tracer Test," Journal of the Korean Society for Environmental Analysis, Vol. 5, No. 3, pp. 173-177, 2002.
  4. Bae, B. U., Kim, Y. I., Park, J. H., "Simultaneous Evaluation of Hydraulic Characteristics of Flocculation and Sedimentation Basin in Water Treatment Plant Using Tracer Test," The Institute of Environmental Studies(Deajeon University), Vol. 6, pp. 29-45, 2002.
  5. H. K VERSTEEG, W. MALALASEKERA, "Anintroductionto Computational Fluid Dynamics," PrenticeHall, 1995.
  6. A. Guardoa, M. Coussiratb, M. A. Larrayoza, F. Recasensa, E. Equsquizab, "Influenece of the turbulence model in CFD modeling of wall-to-fluid heat transfer in packed beds," Chemical Engineering Science, pp. 1733-1742, 2004.
  7. Ta, C. T., Brignal, W. J., "Application of Computational Fluid Dynamics Technique to Storage Reservoir Studies," Pergamon Press, Vol. 37, no.2, pp. 219-226, 1998.
  8. Jang, S. C., Park, T. S., Hur, N. S., and Kim, I. H., "CAE/CFD Analysis and Design of High-Pressure Drop Control Valve for Offshore Project," Journal of the Korean Society of Manufacturing Process Engineers, Vol. 14, No. 5, pp. 42-49, 2015. https://doi.org/10.14775/ksmpe.2015.14.5.042
  9. Jeon, E. C., Youn, G. H., and Kang, C. H., "A Study on Effect of Flow Characteristics for Turbine Impeller Shape," Journal of the Korean Society of Manufacturing Process Engineers, Vol. 13, No. 4, pp. 36-43, 2014. https://doi.org/10.14775/ksmpe.2014.13.4.036