References
- ASTM E 779. 2010. Standard test method for determining air leakage rate by fan pressurization. ASTM International.
- Choi, J.S., Ji, K.H., Lee, D.S., Jo, J.H. 2014. A study on uncertainty experiment depending on testers in airtightness measurement of buildings. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems 8(2): 40-45.
- CAN/CGSB 149.10-M86. 1986. Determination of the airtightness of building envelopes by fan depressurization method. Canadian General Standard Board.
- Canada Mortgage and Housing Corporation. 1996. Energy audits of high-rise residential buildings. Research Highlights.
- Hong, B.J., Jun, J.Y., Kim, H.S. 1999. Experimental study on the air permeability of double glazing window in the apartment houses. Journal of the Architectural Institute of Korea Planning 15(4): 213-220.
- ISO 9972. 2015. Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method. International Organization for Standardization.
- Ji, K.H., Shin, H.K., Jo, J.H. 2015. Measurement and comparison of the airtightness of an apartment building by the preparation in ISO 9972. Proceedings of the Architectural Institute of Korea 35(2): 239-240.
- JIS A 2201. 2003. Test method for performance of building airtightness by fan pressurization. Japanese Industrial Standards Committee.
- KEEI. 2015. Yearbook of energy statistics. Korea Energy Economics Institute.
- Kim, G.T., Yoo, J.H., Hwang, H.J., Kim, K.S. 2013. A study on the calculation method of infiltration for detached houses. Korea Journal of Air-Conditioning and Refrigeration Engineering 25(9): 493-498. https://doi.org/10.6110/KJACR.2013.25.9.493
- Kim, H.B., Kim, S.J., Oh, J.K., Park, J.S., Lee, J.J. 2012. Influence of air-tightness on heat energy performance in post and beam building with exposed wood frame. Journal of The Korean Wood Science and Technology 40(5): 319-326. https://doi.org/10.5658/WOOD.2012.40.5.326
- Kim, H.B., Park, J.S., Hong, J.P., Oh, J.K., Lee, J.J. 2014. Air tightness performance of residential timber frame buildings. Journal of The Korean Wood Science and Technology 42(2): 89-100. https://doi.org/10.5658/WOOD.2014.42.2.89
- Kim, S.J., Park, J.S. 2015. Factors of airtightness performance in timber frame buildings. Proceedings of The Korean Society of Wood Science and Technology Annual Meeting 256-257.
- Kim, S.S., Cho, S., Yoon, Y.J., Park, H.S. 2005. The study on the determining of the infiltration coefficient by window types. Journal of the Architectural Institute of Korea Planning 21(4): 183-189.
- Lee, S.B. 1995. An evaluation of airtightness performance and analysis of energy savings potential in apartment housing. Journal of the Korean Solar Energy Society 15(3): 119-125.
- Lee, K.H., Kim, S.M., Park, Y.H., Moon, J.S., Sohn, J.Y. 2005. A study on the air tightness performance and stack effect characteristics in high-rise apartments. Journal of the Architectural Institute of Korea Planning 21(12): 279-286.
- Lee, D.S., Ji, K.H., Jo, J.H. 2014. Study on the establishment of large building airtightness measurement standards. Journal of the Korean Solar Energy Society 34(1): 117-124. https://doi.org/10.7836/kses.2014.34.1.117
- Lee, S.I., Kim, J.G., Kim, S.H., Kim, J.H., Jeong, H.G., Jang, C.Y. 2015. An analysis of the airtightness performance and heating energy demand according to building structural characteristics - Focused on newly apartment houses. Journal of the Korea Institute of Ecological Architecture and Environment 15(2): 109-115.
- Lee, Y.G., Shin, C.W. 2013. The air leakage characteristics and airtightness performance of a newly built apartment. Korea Journal of Air-Conditioning and Refrigeration Engineering 25(11): 606-611. https://doi.org/10.6110/KJACR.2013.25.11.606
- Shin, H.K., Jo, J.H. 2011. Comparison of test conditions of the fan pressurization method in measuring the building airtightness. Journal of the Architectural Institute of Korea Planning 27(8): 279-286.
- Yoon, J.H., Park, J.W., Lee, K.S., Baek, N.C., Shin, U.C. 2008. A study on the measurement of airtightness performance of detached houses in Chung-cheong area. Journal of the Korean Solar Energy Society 28(5): 65-71.