DOI QR코드

DOI QR Code

Evaluation of Fire Resistance for Composite Column Coated Intumescent Paint According to Loading and Unloading Test

재하 및 비재하 가열 실험을 통한 피복된 합성기둥의 내화성능 평가

  • Kim, Sun-Hee (Department of Architectural Engineering, University of Seoul)
  • 김선희 (서울시립대학교 건축공학과)
  • Received : 2016.10.14
  • Accepted : 2017.01.18
  • Published : 2017.03.30

Abstract

Concrete Filled steel Tube columns are widely employed in construction field thanks to their structural efficiencies by avoiding stress concentration area and improving workability in fabrication and maximizing the composite effect. Although CFT columns have structural advantages over other members and are widely used, they are classified as non-fireproof in Korea because the steel tubes are directly exposed to a fire. Thus, fire coating required for the columns by the law results in inefficient design. This study suggests CFT columns with reduced Intumescent paint coating to enable improved fire-resistance performance for 2 ~ 3 hours. The purpose of the study is to analyses their fire-resistance performance using the variable of experimental method (loading and unloading) which is the major factor in the performance and suggest efficient functional design with reduced Intumescent paint coating.

Keywords

Acknowledgement

Supported by : 국토교통부, 한국연구재단

References

  1. Matsui, C., Tsuda, K., Yamaji, Y., & Fujinaga, T. (1998). Structural performance and axial load limit of concrete filled steel square tubular columns. Journal Structures Constructions Engineering, AIJ Vol 504 pp.103-110.
  2. Liang, QQ, Uy, B., & Liew, JYR. (2006). Nonlinear analysis of concrete-filled thin-walled steel box columns with local buckling effects. Journal Constructions Steel Research Vol 62 pp581-591. https://doi.org/10.1016/j.jcsr.2005.09.007
  3. Korea Institute of Civil Engineering and Building Technology(KICT) web-site resource information. Fire resistance certification notice. (http://www.kict.re.kr/060305/contents_index/pid/31) (in korean)
  4. Korea Institute of Civil Engineering and Building Technology(KICT) (2012). Guide of Fire resistance certification and management task. (in korean)
  5. Kim, S.H., Won, Y.A., & Choi, S.M. (2012). A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test. Journal of Korean Society of Steel Construction. 24(1) pp81-89. https://doi.org/10.7781/kjoss.2012.24.1.081
  6. Kim, S.H., Yom, K.S., & Choi, S.M. (2013). Evaluation of the Fire Resistance Performance of interior Anchor Type CFT Columns through Loaded Heating Test. International Journal of High-rise buildings. Vol.2 No.1 pp39-48.
  7. Kim, S.H., Yom, K.S., & Choi, S.M. (2014). Improving fire performance with fibers for internally anchored square composite columns, Journal of Constructional Steel Research 103 pp264-274. https://doi.org/10.1016/j.jcsr.2014.09.003
  8. Kim, S.H., Yom, K.S., & Choi, S.M. (2015). Fire resistance performance of welded built-up square CFT columns with reduced intumescent paint. Application of Structural Fire Engineering. Vol. 6 No.2 pp103-111. https://doi.org/10.1260/2040-2317.6.2.103
  9. Olivier, V., Bailey, C.G., Hawes, M., Nadjai, A., Simms, W.I., Zhao, B., Gernay, T., & Franssen, J.M. (2011). Large-Scale Fire Test of Unprotected Cellular Beam Acting in Membrane Action. Journal of Structural Fire Engineering, Vol 2. No 4. pp. 259-267. https://doi.org/10.1260/2040-2317.2.4.259
  10. KS F-2257-1 Methods of fire resistance test for elements of building construction- Specific requirements for columns. (2007). (in korean)
  11. Recommendations for design and construction of concrete-filled steel tubular structures, Architectural Institute of Japan. (1997).
  12. ISO 834-11:2014 Fire resistance tests - Elements of building construction - Part 11: Specific requirements for the assessment of fire protection to structural steel elements.
  13. EN 1993-1-2 (2004). Eurocode 3: Design of concrete structures-Part 1-2: Structural fire design. CEN, European Committee for Standardization, Brussels, Belgium.
  14. Kim, S.H., Yom, K.S., & Choi, S.M. (2014). Clarification of the thermal properties of intumescent paint and suggestion of the required fire Protection thickness for steel and composite columns, J. Korean Society for Advanced Composite Structures Vol.6 No1 pp21-29. (in korean) https://doi.org/10.11004/kosacs.2015.6.1.021
  15. Andrew H. Buchanan (2002). Structural Design for Fire Safety, Jone Wiley & Sons, LTD.