DOI QR코드

DOI QR Code

전단철근으로 보강되지 않은 강섬유보강 초고강도콘크리트의 전단강도에 대한 실험적 연구

Experimental Study on the Shear Strength of Fiber Reinforced Ultra High Strength Concrete without Stirrups

  • 투고 : 2015.08.21
  • 심사 : 2017.02.07
  • 발행 : 2017.03.30

초록

In this study, fiber reinforced ultra high strength concrete beams were tested defining the shear behavior of fiber reinforced ultra high strength concrete and evaluating the previously suggested equations for shear strength of concrete members. The main variables of test are compressive strength of concrete(100, 200 MPa), volume fraction of steel fiber(0, 2%), shear-span to depth ratio(3.4, 2.0). According to the test results, specimens without fiber experienced the abrupt shear failure. In the case of fiber reinforced specimen with shear span ratio of 3.4, failure mode of test specimen is changed into flexural failure. And specimen with shear span ratio 2.0 experienced shear-compression failure mode. However, shear strength increase caused by the increase of compressive strength of concrete is not higher than effect of steel fiber inclusion. In order to make safe design of fiber reinforced ultra high strength concrete under shear, shear strength estimation equations are evaluated. Comparing estimated value with test results, shear strength contribution of matrix is over-estimated and shear strength contribution of steel fiber is under-estimated. Among all equations, equation of AFGC-Setra is most accurate.

키워드

과제정보

연구 과제 주관 기관 : 국토교통부, 미래창조과학부

참고문헌

  1. Gustavo J. Parra-Montesinos(2006). Shear Strength of Beams with Deformed Steel Fibers, Concrete international, 28(11), 57-66.
  2. Korea Concrete Institute(2012). Concrete Design Code and Commentary, Kimoondang Publishing Company, Seoul, Korea, 154.
  3. ACI Committee 318(2008). Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary, American Concrete Institute, Farmington Hills, Mich. 171.
  4. Comite Euro-International du Beton(2012). CEB-FIP Model Code 2010 - Final draft, vol. 1. 220.
  5. Japan Society of Civil Engineers (2008). Recommendations for Design and Construction of High Performance Fiber Reinforced Cement Composites with Multiple Fine Cracks (HPFRCC), Concrete Engineering Series, 82, 30.
  6. ASCE-ACI Commitee 445 on Shear and Torsion (1998). Recent approaches to shear design of structural concrete. Journal of Structure Engineering, 124(12), 1375-1417 https://doi.org/10.1061/(ASCE)0733-9445(1998)124:12(1375)
  7. European Commitee for Standardization (CEN) (2004). Design of concrete structures-Part 1-1: General rules and rules for buildings. Eurocode 2, Brussels, Belgium., 84.
  8. NewZealand Standard (2006). New Zealand Concrete Structures Standards (NZS 3101), 84.
  9. Japan Society of Civil Engineering(2008). Standard Specifications for Concrete Structures-Design, JSCE Guideline for Concrete, No. 15, 154.
  10. AFGC Scientific and Technical Committee(2002). Ultra High Performance Fiber-Reinforced Concretes : Interim Recommendation, Documents scientifiques et techniques, 61.
  11. Japan Society of Civel Engineering(2006). Recommendations for design and construction of ultra high strength fiber reinforced concrete structures (Draft), Concrete Committee of Japan Society of Civil Engineers (JSCE), JSCE Guideline for Concrete, No. 9, 26.
  12. Narayanan, R., & Darwish, I. Y. S. (1987). Use of Steel Fibers as Shear Reinforcement, ACI Structural Journal, 84(3), 216-227.
  13. A1-Ta'an, S. A., & A1-Feel, J. R. (1990). Evaluation of Shear Strength of Fibre-Reinforced Concrete Beams Cement &Concrete Composites 12, 87-94. https://doi.org/10.1016/0958-9465(90)90045-Y
  14. Khuntia, M., Stojadinovic, B., & Subhash C. Goel. (1999). Shear Strength of Normal and High-Strength Fiber Reinforced Concrete Beams without Stirrups, ACI Structural Journal, 96(2), 282-290.
  15. Samir A. Ashour, Ghazi S. Hasanain, & Faisal F. Wafa. (1992). Shear Behavior of High-Strength Fiber Reinforced Concrete Beams, ACI Structural Journal, 89(2), 176-184
  16. Swamy, R. N., & Mangat, P. S. (1976). Interfacial Bond Stress in Steel Fiber Cement Composites, Cement and Concrete Research, 6, 641-650. https://doi.org/10.1016/0008-8846(76)90028-4
  17. Zsutty, T. (1968). Beam Shear Strength Prediction by Analysis of Existing Data, ACI JOURNAL, Proceedings 65(11), 943-951.
  18. KS D 3504(2011). Steel bars for concrete reinforcement, Korean Agency for Technology and Standards, 1-30.
  19. Richard, P., & Cheyrezy, M. H. (1994). Reactive Powder Concretes with High Ductility and 200-800MPa Compressive Strength, ACI SP 144, 507-518.
  20. KS F 2405(2010). Standard Test Method for Compressive Strength of Concrete, Korean Agency for Technology and Standards, 1-16.
  21. KS F 2423(2011). Method of test for splitting tensile strength of concrete, Korean Agency for Technology and Standards, 1-12.
  22. Japan Concrete Institute Standard (2003). Method of test for load-displacement curve of fiber reinforced concrete by use of notched beam : JCI-S-002-2003, Japan Concrete Institute, Research Committees, 1-6.