DOI QR코드

DOI QR Code

Alternatives to Enhance Flat Slab Ductility

  • Husain, Mohamed (Structural Engineering Department, Faculty of Engineering, Zagazig University) ;
  • Eisa, Ahmed S. (Structural Engineering Department, Faculty of Engineering, Zagazig University) ;
  • Roshdy, Ramy (Structural Engineering Department, Faculty of Engineering, Zagazig University)
  • Received : 2016.01.23
  • Accepted : 2016.11.17
  • Published : 2017.03.30

Abstract

Flat slab systems are vastly used in multi-story buildings because of their savings in story height and construction time, as well as for their flexibility in architectural remodeling. However, they frequently suffer brittle punching-shear failure around columns, especially when subjected to lateral loads. Therefore, seismic codes labeled flat slabs as non-ductile systems. This research goal is investigating some construction alternatives to enhance flat slab ductility and deformability. The alternatives are: adding different types of punching-shear reinforcement, using discreet fibers in concrete mixes, and increasing thickness of slab around columns. The experimental study included preparation and testing of seven half-scale interior slab-column connections up to failure. The first specimen is considered a reference, the second two specimens made of concrete mixes with different volumetric ratios of polymer fibers. Another three specimens reinforced with different types of punching-shear reinforcement, and the last specimen constructed with drop panel of inverted pyramidal shape. It is found that using the inverted pyramid-shape drop panel of specimen, increases the punching-shear capacity, and the initial and the post-cracking stiffnesses. The initial elastic stiffnesses are different for all specimens especially for the slab with closed stirrups where it is experienced the highest initial stiffness compared to the reference slab.

Keywords

References

  1. ACI 421-1R. (2008). Guide to shear reinforcement for slabs. Farmington Hills, MI: American Concrete Institute.
  2. Broms, C. E. (2007). Ductility of flat plates: Comparison of shear reinforcement systems. ACI Structural Journal, 104(6), 703.
  3. Carvalho, G. (2011). Analise Sismica de Edificios de Betao Armado Estudo de Alternativas de Modelacao Analise Nao-Linear. Master's thesis, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Portugal.
  4. Chana, P. S., & Desai, S. B. (1992). Design of shear reinforments against punching. The Structural Engineer, 70(5), 159-164.
  5. Dam, T. X., & Wight, J. K. (2015). Flexurally-triggered punching shear failure of reinforced concrete slab-column connections reinforced with headed shear studs arranged in orthogonal and radial layout. Engineering Structures, 110, 258-268.
  6. Dinh, H. H., Montesinos, G. J., & Wight, J. K. (2010). Shear behavior of steel fiber-reinforced concrete beams without stirrups reinforcements. ACI Structural Journal, 107(5), 597-606.
  7. Dovich, L., & Wight, J. K. (1996). Lateral response of older flat slab frames and the economic effect on retrofit. Earthquake Spectra, 12(4), 667-691. https://doi.org/10.1193/1.1585905
  8. Eurocode 8-EC8. (2004). Design provision for earthquake resistance of structures. EN 1998-1-1.
  9. Graf, W. P., & Mehrain, M. (1992). Analysis and testing of a flat slab concrete building. In World conference on earthquake engineering, Rotter Dam, ISBN90 54100605.
  10. Hawkins, N. M. (1974). Shear strength of slabs with shear reinforcement. ACI Publication, 42(34), 785-815.
  11. ICC, International Building Code-IBC. (2009). Birmingham, AL: International Code Council.
  12. Matzke, E. M., Lequesne, R. D., Parra-Montesinos, G. J., & Shield, C. K. (2015). Behavior of biaxially loaded slabcolumn connections with shear studs. ACI Structural Journal, 112(3), 335.
  13. Meisami, M., Mostofinejad, D., & Nakamura, H. (2013). Punching shear strengthening of two-way flat slabs with CFRP grids. Journal of Composites for Construction, 18(2). doi:10.1061/(ASCE)CC.1943-5614.0000443.
  14. Oliveira, D. R., Melo, G. S., & Regan, P. E. (2000). Punching strengths of flat plates with vertical or inclined stirrups. ACI Structural Journal, 97(3), 485-491.
  15. Park, R., & Paulay, T. (1974). Reinforced concrete structures. New York: Wiley.
  16. Paulay, T., & Priestley, M. J. N. (1992). Seismic design of reinforced concrete and masonry buildings. New York: Wiley.
  17. Regan, P. E. (1981). Behavior of reinforced concrete flat slabs. Technical Report 89, Construction Industry Research and Information Association (CIRIA), London.
  18. Regan, P. E., & Braestrup, M. W. (1985). Punching shear in reinforced concrete. Comite Euro-International du Beton, Bulletin d'Information, No. 168.
  19. Robertson, I. N., & Johnson, G. P. (2004). Non-ductile slabcolumn connections subjected to cyclic lateral loading. In 13th World conference on earthquake engineering, Vancouver, BC.
  20. Ruiz, M. F. & Muttoni, A. (2010). Performance and design of punching shear reinforcing systems. In 3rd fib international congress, Maryland.

Cited by

  1. Punching Behaviour of Reinforced Concrete Footings at Testing and According to Eurocode 2 and fib Model Code 2010 vol.11, pp.4, 2017, https://doi.org/10.1007/s40069-017-0213-8
  2. Probabilistic Analysis for Strain-Hardening Behavior of High-Performance Fiber-Reinforced Concrete vol.12, pp.15, 2017, https://doi.org/10.3390/ma12152399
  3. Remediation of Punching Shear Failure Using Glass Fiber Reinforced Polymer (GFRP) Rods vol.13, pp.14, 2017, https://doi.org/10.3390/polym13142369
  4. A comparison of punching shear strengthening of RC flat plates with FRP bars and steel bolts vol.16, pp.None, 2017, https://doi.org/10.1016/j.cscm.2021.e00828