References
- Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997;23:77-85. https://doi.org/10.1016/S0099-2399(97)80250-6
- Arens FC, Hoen MM, Steiman HR, Dietz GC Jr. Evaluation of single-use rotary nickel-titanium instruments. J Endod 2003;29:664-666. https://doi.org/10.1097/00004770-200310000-00013
- Berutti E, Chiandussi G, Paolino DS, Scotti N, Cantatore G, Castellucci A, Pasqualini D. Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study. J Endod 2012;38:505-509. https://doi.org/10.1016/j.joen.2011.12.040
- Gambarini G, Testarelli L, De Luca M, Milana V, Plotino G, Grande NM, Rubini AG, Al Sudani D, Sannino G. The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment. Ann Stomatol (Roma) 2013;4:152-155.
- Giuliani V, Cocchetti R, Pagavino G. Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment. J Endod 2008;34:1381-1384. https://doi.org/10.1016/j.joen.2008.08.002
- Gambarini G, Glassman G. In vitro analysis of efficiency and safety of a new motion for endodontic instrumentation: TF Adaptive. Roots 2013;3:12-15.
- Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE. Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals. J Endod 2015;41:913-915. https://doi.org/10.1016/j.joen.2015.01.023
- Li UM, Lee BS, Shih CT, Lan WH, Lin CP. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. J Endod 2002;28:448-451. https://doi.org/10.1097/00004770-200206000-00007
- Lopes HP, Britto IM, Elias CN, Machado de Oliveira JC, Neves MA, Moreira EJ, Siqueira JF Jr. Cyclic fatigue resistance of ProTaper Universal instruments when subjected to static and dynamic tests. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:401-404. https://doi.org/10.1016/j.tripleo.2010.05.013
- Lopes HP, Elias CN, Vieira MV, Siqueira JF Jr., Mangelli M, Lopes WS, Vieira VT, Alves FR, Oliveira JC, Soares TG. Fatigue life of Reciproc and Mtwo instruments subjected to static and dynamic tests. J Endod 2013;39:693-696. https://doi.org/10.1016/j.joen.2012.11.048
- Rodrigues RC, Lopes HP, Elias CN, Amaral G, Vieira VT, De Martin AS. Influence of different manufacturing methods on the cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod 2011;37:1553-1557. https://doi.org/10.1016/j.joen.2011.08.011
- Elnaghy AM, Elsaka SE. Torsion and bending properties of OneShape and WaveOne instruments. J Endod 2015;41:544-547. https://doi.org/10.1016/j.joen.2014.11.010
- Pedulla E, Lo Savio F, Boninelli S, Plotino G, Grande NM, La Rosa G, Rapisarda E. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod 2016;42:156-159. https://doi.org/10.1016/j.joen.2015.10.004
- Topcuoglu HS, Topcuoglu G, Akti A. Comparative evaluation of cyclic fatigue resistance of D-RaCe and ProTaper retreatment instruments in curved artificial canals. Int Endod J 2016;49:604-609. https://doi.org/10.1111/iej.12488
- Inan U, Aydin C. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment. J Endod 2012;38:108-111. https://doi.org/10.1016/j.joen.2011.09.010
- Hussne RP, Braga LC, Berbert FL, Buono VT, Bahia MG. Flexibility and torsional resistance of three nickeltitanium retreatment instrument systems. Int Endod J 2011;44:731-738. https://doi.org/10.1111/j.1365-2591.2011.01876.x
- Gambarini G, Gergi R, Naaman A, Osta N, Al Sudani D. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion. Int Endod J 2012;45:802-806. https://doi.org/10.1111/j.1365-2591.2012.02036.x
- Gavini G, Caldeira CL, Akisue E, Candeiro GT, Kawakami DA. Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement. J Endod 2012;38:684-687. https://doi.org/10.1016/j.joen.2011.12.033
- Shin CS, Huang YH, Chi CW, Lin CP. Fatigue life enhancement of NiTi rotary endodontic instruments by progressive reciprocating operation. Int Endod J 2014;47:882-888. https://doi.org/10.1111/iej.12233
- Gambarini G, Rubini AG, Al Sudani D, Gergi R, Culla A, De Angelis F, Di Carlo S, Pompa G, Osta N, Testarelli L. Influence of different angles of reciprocation on the cyclic fatigue of nickel-titanium endodontic instruments. J Endod 2012;38:1408-1411. https://doi.org/10.1016/j.joen.2012.05.019
- De-Deus G, Moreira EJ, Lopes HP, Elias CN. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J 2010;43:1063-1068. https://doi.org/10.1111/j.1365-2591.2010.01756.x
Cited by
- Comparison of cyclic fatigue life of nickel-titanium files: an examination using high-speed camera vol.42, pp.3, 2017, https://doi.org/10.5395/rde.2017.42.3.224
- Evaluation of gutta-percha removal from the dentinal tubules using different instrumentation techniques with or without solvent: An In vitro study vol.12, pp.1, 2017, https://doi.org/10.4103/jicdro.jicdro_46_19