초록

An axial fan has competitive advantages that can make air flow more straight and longer and produce larger air volume than the other kinds of fans. In those reasons, axial fans are widely used for ventilator, 4D cinema, duct, and so on. But, as it was designed and manufactured without any mathematical analysis or computer simulations, it is difficult to develop the performance of axial fans. Actually the axial fan is designed and manufactured in industry by imitation or traditional method. Flow velocity and volume of axial fan are changed by pitch angle, frame, the number of blade, camber angle, and chord length. In this paper, the performance of axial fan was analyzed and by computer program known as CFD. Finally, we have designed a new axial fan whose velocity and volume is improved. The performance of new axial fan is also compared with the of conventional fans experimentally.

키워드

참고문헌

  1. Jeon, S. T., Cho, J. T., 2012, Effect of Pitch Angle and Blade Length on an Axial Flow Fan Performance, Korean J. Air conditioning and Ref. Eng., 1:25 43-48.
  2. Kim, C. J., 1996, Effects of pitch angle and maximum camber on an axial flow fan performance, Korean J. Air conditioning and Ref. Eng., W-40 269-274.
  3. Lee, S. J., 2010, Parametric Design of Axial Fan for Air-Conditioning Unit in terms of Aerodynamic Performance and Noise Level, Master Thesis, Inha University, Republic of Korea.
  4. Kim, Y. H., 2007, Design of slim, High-efficient, 3-D Bladed Turbo Fan, Master Thesis, Inha University, Republic of Korea.
  5. Kim, J. M., 2004, Study on Centrifugal Blower with High Inlet Resistance, Master Thesis, Sunmoon Univercity, Republic of Korea.
  6. Google, viewed 3 June 2016, Cordier diagram, .
  7. Dongkun Industrial Co. Ltd, viewed 10 May 2016, .
  8. Wikipedia, viewed 5 March 2016, .