DOI QR코드

DOI QR Code

Evaluation of Strength and Stiffness of the Damper Installed at Beam End for Damage-Controlled Structures

손상제어 구조를 위한 보 단부 설치형 댐퍼의 내력 및 강성평가

  • Received : 2016.10.12
  • Accepted : 2017.01.16
  • Published : 2017.02.28

Abstract

The target in this study is damage-controlled system with damper installed at beam end. This system should have different design method about strength and stiffness of the damper compared with the general parallel connection damping system(such as braces type or stud type etc.), because both arrangement formats of damper are different. However, the design method of damper installed at beam end is not yet available. And relevant internal and external researches have been limited mostly to the structural performance verification by the shape of the connection detail. Therefore, in this paper, it consider the available design value of damper installed at beam end through the analytical study. The purpose of this study is to present the design range of the damper/beam yield strength ratio and stiffness ratio, presented rationale is based on the performance efficiency of the damper and results of the damage analysis of the beam member. It conducted time history analysis to target the structure made up of the presented design range, to verify the validity of the proposed design value.

Keywords

References

  1. Kato, B. & Akiyama, H. (1973). Predictable Properties of Material under Incremental Cyclic Loading, IABSE, Preliminary Publication Lisbon, 119-124
  2. Akiyama, H. (1985). Earthquake-resistant limit-state design for buildings, Univ of Tokyo Pr., Japan
  3. Tsai, K. & Popov, E. (1990). Seismic panel zone design effect on elastic story drift in steel frame, Journal of Structural Engineering, ASCE, 116(12), 3285-3301 https://doi.org/10.1061/(ASCE)0733-9445(1990)116:12(3285)
  4. Kishiki, S., Yamada, S., Takeuch, T., Suzuki, K., Saeki E., & Wada, A. (2004). A study on passice response-controlledstructures with hysteretic dampers at the bottom flange of beam-ends, Passive control symposium 2004, Structural engineering research center, Tokyo Institute of Technology
  5. Oh, S., Kim, Y., & Ryu, H. (2009). Seismic performance of steel structures with slit dampers, Engineering Structures 31, 1997-2008 https://doi.org/10.1016/j.engstruct.2009.03.003
  6. Oh, S. & Jeon, J. (2014). A study on optimum distribution of story shear force coefficient for seismic design of multi-story structure, International Journal of High-Rise Buildings, 3(2), 121-145
  7. Oh, S. & Kim, Y. (2005). Hysteretic behavior of beam-tocolumn connections with slit plate dampers, Journal of the Architectural Institute of Korea, 21(12), 101-108
  8. Oh, S., Kim, Y., Ryu, H., & Kang, C. (2006). Hysteretic characteristics of beam-to-column connections with energy absorption elements at beam bottom flanges, Journal of the Architectural Institute of Korea, 22(8), 29-36
  9. Oh, S. & Park, H. (2013). A Study on beam-to-column connections with plate type energy absorption system, Journal of Korean Society of Steel Construction, 23(1), 103-114