References
- National Institute of Environmental Research. Personal exposure assessment study based on Korean individual's daily time-activity pattern. National Institute of Environmental Research, 2009; p. 61 Available: http://www.prism.go.kr/homepage/researchCommon/downloadResearchAttachFile.do?work_key=001&file_-type=CPR&seq_no=001&pdf_conv_yn=N&research_id=1480000-200900233 [accessed 30 December 2016].
- Institute of Urban Science, University of Seoul. A study on indoor air pollution characterization and management. Ministry of Environment, 2002; p. i Available: http://www.prism.go.kr/homepage/research-Common/downloadResearchAttachFile.do?work_key=001&file_type=CPR&seq_no=001&pdf_conv_yn=N&research_id=1480000-200800499 [accessed 31 December 2016].
- Arundel AV, Sterling EM, Biggin JH, Sterling TD. Indirect Health Effects of Relative Humidity in Indoor Environments. Environmental Health Perspectives. 1986; 65: 351-361.
- Liviana JE, Rohles FH, Bullock PE. Humidity, comfort and contact lenses. American Society of Heating, Refrigerating and Air-Conditioning Engineers Transactions. 1988; 94(Part 1): 3-11.
- Korsgaard J. Preventive measures in house-dust allergy. American Review of Respiratory Disease. 1982; 125(1): 80-84.
- Arlian LG, Bernstein IL, Gallagher JS. The prevalence of house dust mites, dermathphagoides spp. and associated environmental conditions in homes in Ohio. Journal of Allergy and Clinical Immunology. 1982; 69(6): 527-532. https://doi.org/10.1016/0091-6749(82)90178-6
- Murray AB, Zuk P. The seasonal variation in a population of house dust mites in a North American city. Journal of Allergy and Clinical Immunology. 1979; 64(4): 266-269. https://doi.org/10.1016/0091-6749(79)90142-8
- Hemmes JH, Winkler K, Kool SM. Virus survival as a seasonal factor in influenza and poliomyelitis. Antonie Van Leeuwenhoek. 1960; 28(1): 221-233. https://doi.org/10.1007/BF02538737
- Gravesen S. Fungi as a cause of allergic disease, Allergy. 1979; 34(3):135-154. https://doi.org/10.1111/j.1398-9995.1979.tb01562.x
- Wraith DG, Cunnington AM, Seymour WM. The role and allergenic importance of storage mites in house dust and other environments. Clinical and Experimental Allergy. 1979; 9(6): 545-561. https://doi.org/10.1111/j.1365-2222.1979.tb00478.x
- Anderson I, Lundqvist GR, Molhave L. Effect of air humidity and Sulphur dioxide on formaldehyde emission from a construction material (chipboard). Holzforschung und Holzverwertung. 1976; 28(5): 120-121.
- Gupta KC, Ulsamer AG, Preuss PW. Formaldehyde in indoor air: sources and toxicity. Environment International. 1982; 8(1-6): 349-358. https://doi.org/10.1016/0160-4120(82)90049-6
- United States Environmental Protection Agency. Air quality criteria for oxides of nitrogen. Environmental Criteria and Assessment Office, Research Triangle Park, NC.
- Mueller FX, Loeb L, Mapes WH. Decomposition rates of ozone in living areas. Environmental Science and Technology. 1973; 7(4): 342-346. https://doi.org/10.1021/es60076a003
- Cho H, Choi JM, Kim WJ. Assessment of indoor volatile organic compounds (VOCs) and emission characteristics by humidity variation in new apartments. Journal of The Korean Society of Living Environmental System. 2006; 13(4): 283-289.
- Yeom J, Lee D, Lee K, Spengler JD, Kim G, Yu S. The relationship between indoor and outdoor temperature and humidity in two types of residence. Journal of Odor and Indoor Environment. 2014; 13(4): 1-10. https://doi.org/10.15250/joie.2014.13.1.1
- Ministry of Environment, National Institute of Environmental Research. Household inoor air quality management guidance. Ministry of Environment, 2012 Available: http://www.me.go.kr/home/file/readDownload-File.do?fileId=6588&fileSeq=1 [accessed 30 December 2016].
- Seoul Metropolitan Government, Indoor Air Quality Management manual. Seoul Metropolitan Government, 2012; p.21 https://cleanindoor.seoul.go.kr/download.do?fileNo=3869 [accessed 30 December 2016].
- Urakawa H, Tajima Y, Numata Y, Tsuneda S. Low temperature decreases the phylogenetic diversity of ammonia-oxidizing archaea and bacteria in aquarium biofiltration systems. Applied and Environmental Microbiology, 2008; 74(3): 894-900. https://doi.org/10.1128/AEM.01529-07