DOI QR코드

DOI QR Code

Automatic Detection of Congestive Heart Failure and Atrial Fibrillation with Short RR Interval Time Series

  • Yoon, Kwon-Ha (Dept. of Radiology, Wonkwang University College of Medicine) ;
  • Nam, Yunyoung (Dept. of Computer Science and Engineering, Soonchunhyang University) ;
  • Thap, Tharoeun (Dept. of Biomedical Engineering, Wonkwang University College of Medicine) ;
  • Jeong, Changwon (Dept. of Biomedical Engineering, Wonkwang University College of Medicine) ;
  • Kim, Nam Ho (Dept. of Cardiology, Wonkwang University College of Medicine) ;
  • Ko, Joem Seok (Dept. of Cardiology, Wonkwang University College of Medicine) ;
  • Noh, Se-Eung (Dept. of Rehabilitation Medicine, Wonkwang University College of Medicine) ;
  • Lee, Jinseok (Dept. of Biomedical Engineering, Wonkwang University College of Medicine)
  • Received : 2015.09.24
  • Accepted : 2016.05.09
  • Published : 2017.01.02

Abstract

Atrial fibrillation (AF) and Congestive heart failure (CHF) are increasingly widespread, costly, deadly diseases and are associated with significant morbidity and mortality. In this study, we analyzed three statistical methods for automatic detection of AF and CHF based on the randomness, variability and complexity of the heart beat interval, which is RRI time series. Specifically, we used short RRI time series with 16 beats and employed the normalized root mean square of successive RR differences (RMSSD), the sample entropy and the Shannon entropy. The detection performance was analyzed using four large well documented databases, namely the MIT-BIH Atrial fibrillation (n=23), the MIT-BIH Normal Sinus Rhythm (n=18), the BIDMC Congestive Heart Failure (n=13) and the Congestive Heart Failure RRI databases (n=25). Using thresholds by Receiver Operating Characteristic (ROC) curves, we found that the normalized RMSSD provided the highest accuracy. The overall sensitivity, specificity and accuracy for AF and CHF were 0.8649, 0.9331 and 0.9104, respectively. Regarding CHF detection, the detection rate of CHF (NYHA III-IV) was 0.9113 while CHF (NYHA I-II) was 0.7312, which shows that the detection rate of CHF with higher severity is higher than that of CHF with lower severity. For the clinical 24 hour data (n=42), the overall sensitivity, specificity and accuracy for AF and CHF were 0.8809, 0.9406 and 0.9108, respectively, using normalized RMSSD.

Keywords

References

  1. A.S. Go, et al., "Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study," JAMA : the journal of the American Medical Association, vol. 285, no. 18, 2001, pp. 2370-2375. https://doi.org/10.1001/jama.285.18.2370
  2. Y. Miyasaka, et al., "Secular trends in incidence of atrial fibrillation in Olmsted County, Minnesota, 1980 to 2000, and implications on the projections for future prevalence," Circulation, vol. 114, no. 2, 2006, pp. 119-125; DOI 10.1161/CIRCULATIONAHA.105.595140.
  3. I. Hajjar and T.A. Kotchen, "Trends in prevalence, awareness, treatment, and control of hypertension in the United States, 1988-2000," JAMA : the journal of the American Medical Association, vol. 290, no. 2, 2003, pp. 199-206; DOI 10.1001/jama.290.2.199.
  4. E. Q. Wu, et al., "Economic burden and comorbidities of atrial fibrillation in a privately insured population," Current medical research and opinion, vol. 21, no. 10, 2005, pp. 1693-1699; DOI 10.1185/030079905X65475.
  5. S.A. Lubitz, et al., "Atrial fibrillation in congestive heart failure," Heart failure clinics, vol. 6, no. 2, 2010, pp. 187-200; DOI 10.1016/j.hfc.2009.11.001.
  6. M. M. Scheinman, "Atrial fibrillation and congestive heart failure: the intersection of two common diseases," Circulation, vol. 98, no. 10, 1998, pp. 941-942. https://doi.org/10.1161/01.CIR.98.10.941
  7. S.A. Hunt, et al., "ACC/AHA guidelines for the evaluation and management of chronic heart failure in the adult: executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to revise the 1995 Guidelines for the Evaluation and Management of Heart Failure)," Journal of the American College of Cardiology, vol. 38, no. 7, 2001, pp. 2101-2113. https://doi.org/10.1016/S0735-1097(01)01683-7
  8. M. H. Chin and L. Goldman, "Correlates of major complications or death in patients admitted to the hospital with congestive heart failure," Archives of internal medicine, vol. 156, no. 16, 1996, pp. 1814-1820. https://doi.org/10.1001/archinte.1996.00440150068007
  9. J. Lee, et al., "Time-varying coherence function for atrial fibrillation detection," IEEE transactions on bio-medical engineering, vol. 60, no. 10, 2013, pp. 2783-2793; DOI 10.1109/TBME.2013.2264721.
  10. S. Dash, et al., "Automatic real time detection of atrial fibrillation," Annals of biomedical engineering, vol. 37, no. 9, 2009, pp. 1701-1709; DOI 10.1007/s10439-009-9740-z.
  11. D.E. Lake and J.R. Moorman, "Accurate estimation of entropy in very short physiological time series: the problem of atrial fibrillation detection in implanted ventricular devices," American journal of physiology. Heart and circulatory physiology, vol. 300, no. 1, 2011, pp. H319-325; DOI 10.1152/ajpheart.00561.2010.
  12. C. Huang, et al., "A novel method for detection of the transition between atrial fibrillation and sinus rhythm," IEEE transactions on bio-medical engineering, vol. 58, no. 4, 2011, pp. 1113-1119; DOI 10.1109/TBME.2010.2096506.
  13. D.D. McManus, et al., "A novel application for the detection of an irregular pulse using an iPhone 4S in patients with atrial fibrillation," Heart rhythm : the official journal of the Heart Rhythm Society, vol. 10, no. 3, 2013, pp. 315-319; DOI 10.1016/j.hrthm.2012.12.001.
  14. J. Lee, et al., "Atrial fibrillation detection using an iPhone 4S," IEEE transactions on bio-medical engineering, vol. 60, no. 1, 2013, pp. 203-206; DOI 10.1109/TBME.2012.2208112.
  15. G. Casolo, et al., "Decreased spontaneous heart rate variability in congestive heart failure," The American journal of cardiology, vol. 64, no. 18, 1989, pp. 1162-1167. https://doi.org/10.1016/0002-9149(89)90871-0
  16. L. Fei, et al., "Heart rate variability and its relation to ventricular arrhythmias in congestive heart failure," British heart journal, vol. 71, no. 4, 1994, pp. 322-328. https://doi.org/10.1136/hrt.71.4.322
  17. Y. Isler and M. Kuntalp, "Combining classical HRV indices with wavelet entropy measures improves to performance in diagnosing congestive heart failure," Computers in biology and medicine, vol. 37, no. 10, 2007, pp. 1502-1510; DOI 10.1016/j.compbiomed.2007.01.012.
  18. T.P. Thakre and M.L. Smith, "Loss of lag-response curvilinearity of indices of heart rate variability in congestive heart failure," BMC cardiovascular disorders, vol. 6, 2006, pp. 27; DOI 10.1186/1471-2261-6-27.
  19. R. Maestri, et al., "Nonlinear indices of heart rate variability in chronic heart failure patients: redundancy and comparative clinical value," Journal of cardiovascular electrophysiology, vol. 18, no. 4, 2007, pp. 425-433; DOI 10.1111/j.1540-8167.2007.00728.x.
  20. R. A. Thuraisingham, "Preprocessing RR interval time series for heart rate variability analysis and estimates of standard deviation of RR intervals," Computer methods and programs in biomedicine, vol. 83, no. 1, 2006, pp. 78-82; DOI 10.1016/j.cmpb. 2006.05.002.
  21. C. S. Poon and C. K. Merrill, "Decrease of cardiac chaos in congestive heart failure," Nature, vol. 389, no. 6650, 1997, pp. 492-495; DOI 10.1038/39043.
  22. H.M. Al-Angari and A.V. Sahakian, "Use of sample entropy approach to study heart rate variability in obstructive sleep apnea syndrome," IEEE transactions on bio-medical engineering, vol. 54, no. 10, 2007, pp. 1900-1904; DOI 10.1109/TBME.2006.889772.
  23. L. Faes, et al., "Time-varying surrogate data to assess nonlinearity in nonstationary time series: application to heart rate variability," IEEE transactions on biomedical engineering, vol. 56, no. 3, 2009, pp. 685-695; DOI 10.1109/TBME.2008.2009358