초록
Arago's disk system consists of a speed controller of the DC motor (inner loop controller) and a position controller of the magnetic bar angle (main controller), which are implemented by the design of the PI and PID controller, respectively. First, we analyzed the nonlinear characteristics of the Arago disk system and found the operating point range of three locations as a result. In this paper, a gain scheduler method was applied to guarantee a constant control performance in the range of $0{\sim}130^{\circ}C$, and a structure to change the controller according to the control reference value based on the previously obtained operating points was experimentally implemented. The Distributed Control Systems (DCS) configuration using the Controller Area Network (CAN) was used to verify the proposed method by improving the operational efficiency of the entire experimental system. So, simplicity of the circuit and easy diagnosis were achieved through a single CAN bus communication.