DOI QR코드

DOI QR Code

Repair Integrity and Functional Outcomes after Arthroscopic Repair of Transtendinous Full-thickness Rotator Cuff Tears Minimum Two-year Follow-up

  • Kim, Kyung Cheon (Shoulder Center and Department of Orthopedic Surgery, TanTan Hospital) ;
  • Lee, Woo-Yong (Department of Orthopedic Surgery, Chungnam National University School of Medicine) ;
  • Shin, Hyun Dae (Department of Orthopedic Surgery, Chungnam National University School of Medicine) ;
  • Kim, Young-Mo (Department of Orthopedic Surgery, Chungnam National University School of Medicine) ;
  • Han, Sun Cheol (Shoulder Center and Department of Orthopedic Surgery, TanTan Hospital)
  • Received : 2017.09.04
  • Accepted : 2017.10.31
  • Published : 2017.12.31

Abstract

Background: To evaluate the clinical outcomes and associated repair integrity in patients treated with arthroscopic repair for a transtendinous rotator cuff tear followed by resection of the remnant rotator cuff tendon. Methods: Between July 2007 and July 2011, we retrospectively reviewed patients who were treated for transtendinous full-thickness tears in the tendinous portion of the rotator cuff by arthroscopic repair. Clinical outcomes were evaluated using the American Shoulder and Elbow Surgeons (ASES) score, the Shoulder Rating Scale of the University of California at Los Angeles (UCLA), the Constant-Murley score, a visual analogue scale (VAS) pain score, and range of motion (ROM). The repair integrity was determined by magnetic resonance imaging or ultrasonography. Results: There were 19 shoulders with transtendinous full-thickness tears in the tendinous portion of the rotator cuff. The ASES, UCLA, Constant-Murley, and VAS pain scores showed significant improvements in function and symptoms (all p<0.001). The active ROM for forward flexion and abduction was also significantly improved (p=0.002 and p<0.001, respectively). The postoperative radiological examination showed cuff integrity without a re-tear in 68.4% of patients. However, the UCLA, ASES, and Constant-Murley scores were not significantly different between healed and re-torn group (p=0.530, p=0.885, and p=0.262, respectively). Conclusions: Although repair of transtendinous rotator cuff tears followed by resection of the remnant rotator cuff tendon in the footprint has a relatively high re-tear rate, no significant difference was observed in the short-term clinical results between the re-tear and healed groups.

Keywords

References

  1. Walcott ME, Daniels SD, Sinz NJ, Field LD, Higgins LD. Traumatic full-thickness transtendinous rotator cuff tears: a case series. J Shoulder Elbow Surg. 2017;26(1):62-7. https://doi.org/10.1016/j.jse.2016.04.023
  2. Richards RR, An KN, Bigliani LU, et al. A standardized method for the assessment of shoulder function. J Shoulder Elbow Surg. 1994;3(6):347-52. https://doi.org/10.1016/S1058-2746(09)80019-0
  3. Ellman H, Hanker G, Bayer M. Repair of the rotator cuff. Endresult study of factors influencing reconstruction. J Bone Joint Surg Am. 1986;68(8):1136-44. https://doi.org/10.2106/00004623-198668080-00002
  4. Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;(214):160-4.
  5. Sugaya H, Maeda K, Matsuki K, Moriishi J. Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy. 2005;21(11):1307-16. https://doi.org/10.1016/j.arthro.2005.08.011
  6. Trantalis JN, Boorman RS, Pletsch K, Lo IK. Medial rotator cuff failure after arthroscopic double-row rotator cuff repair. Arthroscopy. 2008;24(6):727-31. https://doi.org/10.1016/j.arthro.2008.03.009
  7. Cho NS, Yi JW, Lee BG, Rhee YG. Retear patterns after arthroscopic rotator cuff repair: single-row versus suture bridge technique. Am J Sports Med. 2010;38(4):664-71. https://doi.org/10.1177/0363546509350081
  8. Kim KC, Shin HD, Cha SM, Kim JH. Repair integrity and functional outcomes for arthroscopic margin convergence of rotator cuff tears. J Bone Joint Surg Am. 2013;95(6):536-41. https://doi.org/10.2106/JBJS.L.00397
  9. Meyer DC, Wieser K, Farshad M, Gerber C. Retraction of supraspinatus muscle and tendon as predictors of success of rotator cuff repair. Am J Sports Med. 2012;40(10):2242-7. https://doi.org/10.1177/0363546512457587
  10. Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL. Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg. 2006;15(3):290-9. https://doi.org/10.1016/j.jse.2005.09.017
  11. Jost B, Pfirrmann CW, Gerber C, Switzerland Z. Clinical outcome after structural failure of rotator cuff repairs. J Bone Joint Surg Am. 2000;82(3):304-14.
  12. Liu SH, Baker CL. Arthroscopically assisted rotator cuff repair: correlation of functional results with integrity of the cuff. Arthroscopy. 1994;10(1):54-60. https://doi.org/10.1016/S0749-8063(05)80293-2
  13. Barber FA, Coons DA, Ruiz-Suarez M. Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures. Arthroscopy. 2007;23(4):355-60. https://doi.org/10.1016/j.arthro.2006.12.009
  14. Bardana DD, Burks RT, West JR, Greis PE. The effect of suture anchor design and orientation on suture abrasion: an in vitro study. Arthroscopy. 2003;19(3):274-81. https://doi.org/10.1053/jars.2003.50032
  15. Bynum CK, Lee S, Mahar A, Tasto J, Pedowitz R. Failure mode of suture anchors as a function of insertion depth. Am J Sports Med. 2005;33(7):1030-4. https://doi.org/10.1177/0363546504271746
  16. Cummins CA, Murrell GA. Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elbow Surg. 2003;12(2):128-33. https://doi.org/10.1067/mse.2003.21
  17. Gerber C, Meyer DC, Frey E, et al. Neer Award 2007: reversion of structural muscle changes caused by chronic rotator cuff tears using continuous musculotendinous traction. An experimental study in sheep. J Shoulder Elbow Surg. 2009;18(2):163-71. https://doi.org/10.1016/j.jse.2008.09.003
  18. Goutallier D, Postel JM, Gleyze P, Leguilloux P, Van Driessche S. Influence of cuff muscle fatty degeneration on anatomic and functional outcomes after simple suture of full-thickness tears. J Shoulder Elbow Surg. 2003;12(6):550-4. https://doi.org/10.1016/S1058-2746(03)00211-8
  19. Mahar A, Allred DW, Wedemeyer M, Abbi G, Pedowitz R. A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair. Arthroscopy. 2006;22(2):130-5. https://doi.org/10.1016/j.arthro.2005.08.042
  20. Su WR, Budoff JE, Luo ZP. The effect of anterosuperior rotator cuff tears on glenohumeral translation. Arthroscopy. 2009;25(3):282-9. https://doi.org/10.1016/j.arthro.2008.10.005
  21. Yamaguchi K, Tetro AM, Blam O, Evanoff BA, Teefey SA, Middleton WD. Natural history of asymptomatic rotator cuff tears: a longitudinal analysis of asymptomatic tears detected sonographically. J Shoulder Elbow Surg. 2001;10(3):199-203. https://doi.org/10.1067/mse.2001.113086