Purpose: The purpose of the study was to investigate knowledge and attitudes of students majoring in health-related fields toward automated external defibrillator (AED) and to identify the influencing factors of knowledge and attitudes in AED use among the students. Methods: Data were collected from 346 students and analyzed using descriptive statistics, t-tests, one-way ANOVA, post hoc $Scheff{\acute{e}}$ test, Pearson's correlation coefficient, and hierarchical multiple regression analysis, with SPSS Win 20.0 program. Results: Overall knowledge of AED in health-related major students, except paramedics and physical therapy was relatively low while attitudes were at moderate level. There were statistically significant differences in knowledge according to age, grade, major, cardiopulmonary resuscitation (CPR) awareness, exposure to AED and CPR education; and differences in attitude according to major, health status, health awareness, CPR awareness, exposure to AED, and CPR education. Significant factors explained 63% of knowledge on AED (F= 43.96, p<.001) and 37% of attitudes on AED (F= 15.84, p<.001). Conclusion: The study findings suggest that systemic education programs on AED should be implemented during undergraduate curriculum to improve survival rate of sudden cardiac arrest.

키워드

참고문헌

  1. Ministry of Health and Welfare. Press release. Available at: http://www.mohw.go.kr/front_new/al/sal0301vw.jsp?PAR_MENU_ID=04&MENU_ID=0403&CONT_SEQ=299940&page=1 2014.
  2. Korean Statistical Information Service. Acute cardiac arrest survey: standardized incidence rate. Available at: http://kosis.kr/statHtml/statHtml.do?orgId=117&tblId=DT_11788N_001&vw_cd=MT_ZTITLE&list_id=D1_11788&seqNo=&lang_mode=ko&language=kor&obj_var_id=&itm_id=&conn_path=E1 2016.
  3. Cobb LA, Fahrenbruch CE, Olsufka M, Copass MK. Changing incidence of out of hospital ventricular fibrillation, 1980-2000. JAMA 2002;288(23):3008-13. https://doi.org/10.1001/archinte.1993.00410110070011
  4. Cho BJ, Kim SR. The effect factors of survival rate in the patients with cardiac arrest. Journal of the Korea Academia-Industrial cooperation Society 2014;15(2):760-6. https://doi.org/10.5762/KAIS.2014.15.2.760
  5. Caffrey SL, Willoughby PJ, Pepe PE, Becker LB. Public use of automated external defibrillators. N Engl J Med 2002;347(16):1242-7. https://doi.org/10.1056/NEJMoa020932
  6. White MJ, Loccoh EC, Goble MM, Yu SK, Duquette D, Davis MM et al. Availability of automated external defibrillators in public high schools. J Pediatrics 2016;172:142-6e1. https://doi.org/10.1016/j.jpeds.2016.02.010
  7. Lee HB. A Study on the application of automated external defibrillator in Daejeon metropolitan area. Daejeon Development Institute. Retrieved August 17, 2017 from http://www.dsi.re.kr/board.es?mid=a10101000000&bid=0001&act=view&list_no=4600
  8. Colquhoun MC. Chamberlain DA. Newcombe RG. Harris R. Harris S. Peel K et al. A national scheme for public access defibrillation in England and Wales. Resuscitation 2008;78(3):275-80. https://doi.org/10.1016/j.resuscitation.2008.03.226
  9. Valenzuela TD, Roe DJ, Shan Cretin, Spaite DW, Larsen MP. Estimating effectiveness of cardiac arrest interventions: a logistic regression survival model. Circulation 1997;96:3308-13. https://doi.org/10.1161/01.CIR.96.10.3308
  10. Leem SH. South Korea and Japanese intention to use automated external defibrillators in out of hospital cardiac arrest situations. Korean J Emerg Med Ser 2014;15(1):17-27. https://doi.org/10.14408/KJEMS.2014.18.1.017
  11. Park SG, Park CH, Chae MJ. Knowledge and current status about AED in the public facilities. Korean J Emerg Med Ser 2010;14(3):13-28.
  12. Kwon P, Kim MJ, Lee YM, Yu Ky, Huh Y. Locating automated external defibrillators in a complicated urban environment considering a pedestrian-accessible network that focuses on out-of-hospital cardiac arrests. ISPRS Int J Geo-Inf 2017:6(2):39. http://www.mdpi.com/2220-9964/6/2/39 https://doi.org/10.3390/ijgi6020039
  13. Ministry of Health and Welfare. Press release. Available at: http://www.mohw.go.kr/front_new/al/sal0301vw.jsp?PAR_MENU_ID=04&MENU_ID=0403&CONT_SEQ=339011&page=1 2017.
  14. Ministry of Health and Welfare. Press release. Available at: http://www.mohw.go.kr/front_new/al/sal0301vw.jsp?PAR_MENU_ID=04&MENU_ID=0403&BOARD_ID=140&BOARD_FLAG=00&CONT_SEQ=287690&page=1. 2013
  15. Park SS, Lee CH, An JY. Comparison of educational effects between VSI (video self-instruction) and lecturer-centered learning on AED (automated external defibrillator) in some undergraduates. J Korea Society for School Health Education 2010;11(2):129-40.
  16. Yoon JM, Hwang SO, Cha YS, Kim OH, Kim TH, Jung WJ et al. 'Push Hard and Fast' voice prompt from AED can improve quality of chest compression performed by untrained lay people. J Korean Soc Emerg Med 2014;25(4):435-9.
  17. Park HJ. The investigation into the use and management of automated external defibrillator (AED) in multiple public facilities : focusing on randomly chosen area in Seoul. Unpublished master's thesis, Chung-ang University 2013, Seoul, Korea.
  18. Park CM. The implementation of automated external defibrillator in sport facilities-focused on health/fitness facilities-. The Korean Association of Sports Law 2013;16(4):165-89. https://doi.org/10.19051/kasel.2013.16.4.165
  19. Gang BR, Yang HM, Lee IS. Analysis of contents of website information about CPR and automated external defibrillator. The Korean Journal of Health Service Management 2013;7(3):29-44. https:/doi.org/10.12811/kshsm.2013.7.3.029
  20. Koh CY, Kim CH. Comparing the fully-automated external defibrillator and semi-automated external defibrillator used by laypersons: a simulation study. J Korean Soc Emerg Med 2013;24(4):362-9.
  21. Park JM. The effects of cardiopulmonary resuscitation and automated external defibrillatior education for school teachers. Korean J Emerg Med Ser 2013;17(2):29-41. https://doi.org/10.14408/KJEMS.2013.17.2.029
  22. Shin JH. Performance ability after CPR education of the ground workers in an airport. Korean J Emerg Med Ser 2009;13(3):29-40.
  23. Bae HA. Public access defibrillation program. Korean Journal of Medicine and Law 2008;16(1):7-22.
  24. Lee GH, Kim HT, Choi KH. Research on knowledge and attitudes about CPR of university students. Journal of Korean Society of Sport Policy 2009;13:14-52.
  25. Kim HS, Uhm DC, Hong SW. Factors influencing cardiopulmonary resuscitation performance on a stranger. J Korean Acad Soc Nurs Edu 2010;16(2):339-46. https://doi.org/10.5977/JKASNE.2010.16.2.339
  26. Taniguchi T, Omi W, Inaba H. Attitudes toward automated external defibrillator use in Japan. Resuscitation 2008;79(2):288-91. https://doi.org/10.1016/j.resuscitation.2008.05.011
  27. Lee JH, Sung MH. Factors influencing performance ability of CPR of hospital staffs. Journal of East-West Nursing Research 2013;19(2):96-103. https://doi.org/10.14370/jewnr.2013.19.2.96
  28. Lubin J, Chung SS, Williams K. An assessment of public attitudes toward automated external defibrillators. Resuscitation 2004;62. https://doi.org/10.1016/j.resuscitation.2004.02.006
  29. Woollard M, Whitfield R, Smith A, Colquhoun M, Newcombe RG, Vetter N et al. Skill acquisition and retention in automated external defibrillator (AED) use and CPR by lay responders: a prospective study. Resuscitation 2004;60:17-28. https://doi.org/10.1016/j.resuscitation.2003.09.006