In this paper, we propose a technique to determine the normal and arc of an alternating current using a mixed filter composed of an average filter and a band-pass filter and a frequency analysis. The proposed method uses the moving average filter of the FIR filter structure for noise removal and the band-pass filter of the IIR filter structure for detecting only specific frequency components after normalizing the measured current signal based on the maximum value. After performing Fast Fourier Transform (FFT) using the band-pass filtered signal, the total energy is calculated using the magnitude component of the frequency, and the arc is detected using the magnitude of the calculated energy. In order to show the validity of the proposed method, we experimented with various data and found that arc and steady state can be easily discriminated by calculating spectral energy. Therefore, it is considered that the proposed method can be applied to arc diagnosis of low voltage electric wire.

키워드

참고문헌

  1. Korea Electrical Safety Corporation, "A Statistical Analysis on the Electrical Accidents in 2013," 2014
  2. Underwriters Laboratories, "Standard 1699-Standard for Arc-Fault Circuit-Interrupters," 2006.
  3. Restrepo, Carlos E. "Arc fault detection and discrimination methods," IEEE Conf. on Electrical Contacts, pp.115-122, 2007.
  4. G. D. Gregory, Kon Wong and R. F. Dvorak, "More about arc-fault circuit interrupters," IEEE Transactions on Industry Applications, vol. 40, no. 4, pp. 1006-1011, 2004. https://doi.org/10.1109/TIA.2004.831287
  5. Jeongwoon Ahn, Yong-Taek Oh, "Series Arcing Fault Detection Method Using Harmonics Analysis of Supply Current," Journal of the Korean Institute of IIIuminating and Electrical Installation Engineers, vol. 28, no. 12, pp. 30-37, 2014.
  6. Giovanni Artale, Antonio Cataliotti, Valentina Cosentino, Dario Di Cara, Salvatore Nuccio, and Giovanni Tine, "Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis," IEEE Trans. Instrumentation and Measurement, vol. 66, no. 5, pp. 888-896, 2017. https://doi.org/10.1109/TIM.2016.2627248
  7. Yu-Wei Liu, Chi-Jui Wu, Yi-Chieh Wang, "Detection of serial arc fault on low-voltage indoor power lines by using radial basis function neural network," Electrical Power and Energy Systems, vol. 83, pp. 149-157, 2016. https://doi.org/10.1016/j.ijepes.2016.04.013
  8. Vinay K. Ingle, John G. Proakis, Digital Signal Processing using Matlab, Thomsom, 2007.
  9. Oppenheim, Schafer, DISCRETE-TIME SIGNAL