References
- Schropp, L., Wenzel, A., Kostopoulos, L. & Karring, T. Bone healing and soft tissue contour changes following single-tooth extraction: a clinical and radiographic 12-month prospective study. The International Journal of Periodontics and Restorative Dentistry 2003;23:313-323.
- Araujo, M.G. & Lindhe, J. Dimensional ridge alterations following tooth extraction. An experimental study in the dog. Journal of Clinical Periodontology 2005;32:212?218.
- Araujo, M.G., Sukekava, F., Wennstrom, J.L. & Lindhe, J. Ridge alterations following implant placement in fresh extraction sockets: an experimental study in the dog. Journal of Clinical Periodontology 2005;32:645?652. https://doi.org/10.1111/j.1600-051X.2005.00726.x
- Araujo, M.G., Wennstrom, J.L. & Lindhe, J. Modeling of the buccal and lingual bone walls of fresh extraction sites following implant installation. Clinical Oral Implants Research 2006;17:606?614. https://doi.org/10.1111/j.1600-0501.2006.01315.x
- Botticelli, D., Berglundh, T. & Lindhe, J. Hardtissue alterations following immediate implant placement in extraction sites. Journal of Clinical Periodontology 2004;31:820?828. https://doi.org/10.1111/j.1600-051X.2004.00565.x
- Sanz, M., Cecchinato, D., Ferrus, J., Pjetursson, E.B., Lang, N.P. & Lindhe, J. A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla. Clinical Oral Implants Research 2010;21:13?21. https://doi.org/10.1111/j.1600-0501.2009.01824.x
- Nowzari, H., Chee, W., Yi, K., Pak, M., Chung, W.H. & Rich, S. Scalloped dental implants: a retrospective analysis of radiographic and clinical outcomes of 17 NobelPerfect implants in 6 patients. Clinical Implant Dentistry and Related Research 2006;8:1?10. https://doi.org/10.2310/j.6480.2005.00034.x
- Khraisat, A., Zembic, A., Jung, R.E., Hammerle, C.H.F. Marginal bone levels and soft tissue conditions around single-tooth implants with a scalloped neck design: Results of a prospective 3-year study. Int J Oral Maxillofac Implants 2013;28:550?555. doi: 10.11607/jomi.2544
- Abrahamsson, I., Welander, M., Linder, E. & Berglundh, T. Healing at implants placed in an alveolar ridge with a sloped configuration. An experimental study in dogs. Clinical Implant Dentistry and Related Research, 2012. doi: 10.1111/j.1708-8208.2012.00460.x
- Noelken, R., Donati, M., Fiorellini, J., Gellrich, N.C., Parker W., Wada K., Berglundh T. Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration Clinical Oral Implants Research 2014;25:3?9.
- Holmstrom, J. Fatigue strength of OsseoSpeedTM 4.0S (M1.6) and MicroThreadTM OsseoSpeedTM 4.0 (M2)- a comparative study. Poster. 2008 Astra Tech AB.
- Johansson, H., Hellqvist, J. Functionality of a further developed implant system-- Mechanical integrity. Poster 2014 EAO.
- Rasmusson, L., Roos, J., Bystedt, H. A 10-Year Follow-Up Study of Titanium Dioxide?Blasted Implants. Clinical Implant Dentistry and Related Research 2005;7:36-42 https://doi.org/10.1111/j.1708-8208.2005.tb00045.x
- Botticelli, D., Berglundh, T., Buser, D., Lindhe, J. The jumping distance revisited: An experimental study in the dog. Clin Oral Implants Res 2003 Feb;14(1):35-42.
- Kim, K.S., Lim, Y.J., Kim, M.J., Kwon, H.B., Yang, J.H., Lee, J.B., Yim, S.H. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection, Clin Oral Implants Res 2011;22:834-839. https://doi.org/10.1111/j.1600-0501.2010.02063.x