Light Load Efficiency Improvement in Variable DC-link Voltage Inverter Systems for Home Appliances

  • Park, Hyun Soo (Department of Electrical and Computer Engineering, Sungkyunkawn Univ., Korea) ;
  • Kim, Minkook (Department of Electrical and Computer Engineering, Sungkyunkawn Univ., Korea) ;
  • Lee, Byoung Kuk (Corresponding Author: Department of Electrical and Computer Engineering, Sungkyunkawn Univ., Korea.)
  • Received : 2016.06.03
  • Accepted : 2016.07.18
  • Published : 2016.09.01

Abstract

Keywords

1. Introduction

As power consumption by homes and buildings increases, it is increasingly important to have high-efficiency home appliances, such as air-conditioners and refrigerators. Fig. 1 shows variations in the annual operation time, power consumption, and efficiency of air-conditioners according to the load conditions. As shown in Fig. 1, compared to heavy loads, the duration of power consumption under light loads increases and the efficiency of the inverter compressor gradually decreases. Therefore, it can be noted that in order to decrease the overall power consumption, improvement of the efficiency at light loads is very important because it makes up a large portion of the overall power consumption. A major factor in the efficiency degradation under light loads is the high input voltage with the low back electromotive force (back-EMF) of the driving motor, which lead to very large conduction losses. On the other hand, under heavy loads, the field weakening control to obtain the maximum torque with a given voltage limit degrades the system efficiency.

Fig. 1.Typical example of air-conditioner compressor system load characteristics.

Several kinds of approaches are proposed to overcome these problems. The PWM (Pulse Width Modulation) frequency changing method changes the frequency depending on the load conditions to reduce switching losses; however, the transient state has side effects on THD (Total Harmonic Distortion) and power factor [1]. The nonlinear inductor uses dc bias characteristics in inverse proportion to the inductor current [2]. This method reduces ripples and iron losses by material characteristics, though an additional nonlinear inductor increases conduction losses. Phase shedding uses at least two converters and operates only one of them under light loads to improve system efficiency [3]. However, no less than a pair of converters should be used. Changing the dc-link voltage reduces the conduction losses of inverter in the condition of the back-EMF [4]. In order to change the dc-link voltage, a PFC (Power Factor Correction) circuit could be utilized, which can make the hardware complicated and the efficiency of the PFC should be considered.

In this paper, efficiency improvement under light loads is discussed with dc-link voltage variation considering the efficiency of the inverter and the PFC simultaneously. PFC operation is also discussed because PFC provides a dc-link voltage to improve the efficiency under light loads. In detail, a combination of buck-boost selective control and phase shedding control is used. Moreover, an optimal operation method for dc-link voltage and PFC control is proposed to obtain the minimum power consumption for optimal system efficiency.

 

2. Variable DC-link Voltage Inverter System

Home appliances operated at a current lower than 16 A, such as air-conditioners, should satisfy harmonic standard IEC 61000-3-2 [5]. Therefore, a PFC circuit is usually used to reduce the harmonic component. Moreover, the PFC circuit also controls the power factor and dc-link voltage.

In general, for an inverter compressor system as shown in Fig. 2, the dc-link voltage is not changed by the PFC control. This type of constant dc-link voltage inverter maintains the same voltage level even under a light load that has the low voltage level of the back-EMF. Conduction losses from inverters are relatively large owing to the high voltage difference between the dc-link and the back-EMF. Moreover, the voltage of the back-EMF under a heavy load is almost the same as or slightly lower than the dc-link voltage. In this case, to increase the speed of the motor, a special and complex control method should be used, for example field weakening control. Field weakening control should use the d-axis current, which leads to additional losses from the inverter.

Fig. 2.System block diagram of inverter compressor.

A variable dc-link voltage system is one solution to overcome the problems of constant dc-link voltage inverters and to achieve high efficiency under light loads [6].

In detail, the total loss from a six-switch inverter is the sum of conduction losses and switching losses, as expressed by (1).

where Pconduct is the conduction losses from the inverter, Psw is the switching losses from the inverter, Vnce is the n-th IGBT (Insulated Gate Bipolar Transistor) collector emitter voltage, Ince is the n-th IGBT collector emitter current, Fsw_n is the switching frequency of the n-th IGBT, Esw_n is the energy dissipations of the n-th IGBT, and Ptotal is the total power consumption.

The back-EMF is small with light loads, which gives a large voltage to switch. Therefore, Esw_n(on) and Esw_n(off) from voltage changes are relatively large. In this case, the low dc-link voltage decreases the switching losses from the inverter. On the contrary, the back-EMF is large with a heavy load, which leads to small switching losses from voltage changes. In this case, variation in the dc-link voltage is effective for reducing the switching losses, while conduction losses from the inverter are almost constant with the variance of the dc-link voltage because Vnce is almost constant.

Fig. 3 shows the control concept of the variable dc-link voltage inverter system. This system changes the dc-link voltage according to the speed of the motor. The voltage of the dc-link is high at high speed and low at low speed because the motor speed has a somewhat directly proportional relation to load.

Fig. 3.Control concept of variable dc-link voltage inverter system with variation in motor speed.

It is essential to consider various kinds of conditions to change the dc-link voltage, for example the back-EMF, the voltage limitation of switch, the ripple current, and so on. According to these conditions, some limitation of the dc-link voltage range is needed. The low limit for the dc-link voltage should be set by the efficiency of the PFC circuit and minimum voltage needed to operate the motor. The high limit for the dc-link voltage should be set by the maximum speed of the motor, the efficiency of PFC the circuit, the voltage limitation of the switch, and the internal voltage limitation of the capacitor. Considering various conditions, the low limit for the dc-link voltage was selected as 270 V to satisfy the operation of the motor and the torque limitation of the compressor. The high limit of the dc-link voltage was selected as 400 V to satisfy the internal voltage limitation of the capacitor.

The grid voltage condition has a range of 220-230 V. The peak voltage range after rectifying is from 311 to 325 V. Not only step-up but also step-down functions should be realized to change the rectified voltage to the range of 270-400 V. In order to obtain this range of voltage, both buck and boost operation should be performed. Cascade buck-boost PFC is one of the most suitable topologies to consider the power density and rating voltage of the capacitor [7]. This paper proposes reducing losses in cascade buck-boost PFC. Fig. 4 shows the block diagram of the variable dc-link voltage inverter system.

Fig. 4.Variable dc-link voltage inverter system blocks.

 

3. Proposed Buck-boost Selective and Phase Shedding Control Algorithm

Two kinds of algorithms to improve the efficiency in variable dc-link voltage inverter systems are presented. One is buck-boost selective control and the other is phase shedding control. These two algorithms are merged to achieve high efficiency at the PFC part.

With buck-boost synchronous control, it is possible to do step-up and step-down functions regardless of the load status. The algorithm for the control is simple and always the same for step-up or step-down. The same control signals are used for operating the step-up and step-sown switches.

However, buck-boost synchronous control can deteriorate the efficiency because both switches are operated at the same time. If one of the switches is operated for step-up or step-down, switching losses can be reduced. Buck-boost selective control is one solution to improve efficiency. Fig. 5 shows the PWM waveform of buck-boost synchronous control and buck-boost selective control.

Fig. 5.PWM waveform of buck-boost synchronouscontrol and buck-boost selective control.

Buck-boost selective control selects buck or boost control by comparing the input voltage and the dc-link voltage. According to the selection results, only one switch is fully on or off, which is why the losses with buck-boost selective control are less than those with buck-boost synchronous control [8].

Buck-boost selective control also has the benefit of a power factor and THD because the input current is continuous in boost control.

The loss with buck-boost synchronous control Pbuck_boost_sync is expressed in (2).

where Ps1sync is the loss of S1, Ps2sync is the loss of S2, Ps1sync_cond is the conduction loss of S1, Ps1sync_sw is the switching loss of S1, Ps2sync_cond is the conduction loss of S2, and Ps2sync_sw is the switching loss of S2. Switches S1 and S2 operate at the same time. In this case, switching losses are larger than with only one switch operating.

The loss with buck-boost selective control Pbuck_boost_selective is expressed in (3).

where Pboost is the loss of boost control, Pbuck is the loss of buck control, Ps1_cond_boost is the conduction loss of S1, Ps1_sw_boost is the switching loss of S1, Ps2_cond_buck is the conduction loss of S2, and Ps2_sw_buck is the switching loss of S2. These losses are shown in Fig. 5(b).

In the case of buck-boost selective control, only one switch is operated so the power consumption of buck-boost selective control is less than that of buck-boost synchronous control. Table 1 shows the switch operation and detailed losses for each control.

Table 1.Switch operation for each control

Fig. 6 shows a control block diagram of the two-phase buck-boost selective control. The basic control scheme for buck-boost selective control comes from the voltage difference between the target and the reference. The final control step to select buck switch or boost switch is important. Output comparison between the controlled voltage and the dc-link voltage selects buck control or boost control in buck-boost selective control. The output PWM control signal controls S1 and S2. Power factor was more than 0.99 in simulation all kinds of loads.

Fig. 6.PFC control block for the buck-boost selective control

Phase shedding control uses single phase with light loads and multi-phase (interleaving) operation with heavy loads. With light loads, phase shedding has the benefit of reducing switching and reversing recovery losses. Phase shedding control also reduces the individual inductor capacity. It has the benefit of minimizing inductor losses [3].

Fig. 7 shows the efficiency graph for phase shedding and normal operation.

Fig. 7.Comparison of effects of phase shedding and normal control.

 

4. Experimental Verification

In order to verify the proposed topology and control algorithms, experiments were performed with the 2.2-kW prototype of the system parameters in Table 2. Fig. 8 shows the test-bed for the experiment. Load variation was performed by the test-bed and the dynamo system.

Table 2.Experiment parameters

Fig. 8.Test-bed for variable dc-link voltage inverter system.

The integrated PFC efficiency experiment was carried out with three kinds of conditions.

The first condition is variation of the dc-link voltage. The range of the dc-link voltage is from 270 V to 400 V. The second condition is the control method for the PFC. One is buck-boost selective control and the other is buck-boost synchronous control. The third condition is phase shedding control. Single-phase control and two-phase (non-phase shedding, multi-phase, interleaving) control were tested in the experiment. In the case of single phase, the total acceptable power is half of the maximum. The PWM frequency of PFC is 50 KHz. The control difference between the reference system and the proposed system is expressed in Table 3.

Table 3.Control difference between the reference condition and the proposed condition

According to the input power, these control conditions should be changed. This proposed strategy is expressed in (4).

where p is the input power, fDC_link(p) is the optimal voltage of the dc-link, fPFC(p) is the optimal selection between buck-boost selective control and buck-boost synchronous control to obtain the minimum power consumption, and fPhase(p) is the optimal selection of phase shedding control to obtain minimum power consumption.

The second and third conditions select the values for the control method. On the other hand, the first condition is the optimal voltage value to achieve the minimum power consumption, which is relatively hard to obtain. Thus, with some fixed dc-link voltage condition, the second and third conditions are changed to observe the efficiency variation.

Fig. 9 shows the experimental efficiency of buck-boost selective control and phase shedding with a 270 V dc-link voltage. Buck-boost selective control always has 1-2.5% better performance compared to that of buck-boost synchronous control. In the case of the second condition, buck-boost selective control is the solution to minimizing the power consumption. Phase shedding has 1-2% better performance compared to that of two-phase control. It can be used for half load conditions.

Fig. 9.Experimental efficiency comparison between buck-boost selective control and phase shedding with fixed dc-link voltage.

In case of dc-link voltage, 270 V and 380 V are used to check the efficiency tendency. Fig. 10 shows the experimental efficiency of the variable dc-link voltage and phase shedding. As buck-boost selective control was found to be effective, it is used commonly. 380 V dc-link voltage has good performance compared to that achieved with 270 V in PFC efficiency. This voltage affects not only the PFC efficiency but also the inverter efficiency. System performance should be determined by simultaneously considering the PFC and the inverter.

Fig. 10.Experimental efficiency comparison between variable dc-link voltage and phase shedding with buck-boost selective control.

Fig. 11 shows operation waveform of proposed system in case dc-link voltage is 270 V. Phase difference between input voltage and input current is almost zero regardless of phase shedding control. During the experiment, power factor was more than 0.98 from 200 W to 2200 W. That means PFC operated correctly.

Fig. 11.Experimental waveform between one phase 600 W and two phase 1200 W.

According to the PFC efficiency experimental results, buck-boost selective control is used commonly, and one-phase is used below 1100 W, which is half of the maximum power in the PFC and inverter integration test. These conditions for the PFC and inverter integration test are expressed in Eq. (5).

The total system efficiency can be calculated from multiplication of the PFC part and the inverter part. In the real situation, there are several factors to consider. For example, noise and back-EMF. Therefore, total system efficiency is measured from the test-bed dynamo system. In case of compressor loads, torque variation is not changed widely. In this experiment, torque variation range is 1.9~5.6 Nm and speed variation is 200~3000 RPM to satisfy cycle condition. Torque and speed have proportional relation. Output power has proportional relation in speed. In the test-bed dynamo system, fixed torque is used for simplification.

The optimal voltage to get the best system efficiency can be determined by Eq. (5) and the test-bed dynamo system. The optimal voltage has some sections for convenience. Fig. 12 shows these sections and strategy.

Fig. 12.Summarized control strategy of variable dc-link voltage inverter system.

According to Fig. 12, there are five sections to determine the optimal control strategy from the input power range. For the range below 500 W (section 1), it is desirable to use phase shedding, 270 V dc control. For the range from 500 W to 1100 W (section 2), it is desirable to use phase shedding, 300 V dc control. For the range from 1100 W to 1500 W (section 3), it is desirable to use interleaving, 330 V dc control. For the range from 1500 W to 2100 W (section 4), it is desirable to use interleaving, 380 V dc control. For the range over 2100 W (section 5), it is desirable to use interleaving, 400 V dc control. This strategy is summarized in Table 4.

Table 4.Control strategy for optimal efficiency

Fig. 12 also shows the efficiency of the reference system and Fig. 13 shows the efficiency comparison results. A maximum 6.5% efficiency improvement can be achieved in light load condition. The efficiency improvement can be acquired regardless of load.

Fig. 13.Experimental system efficiency comparison between conventional system and proposed system.

 

5. Conclusion

This paper proposes an efficiency improvement for variable dc-link voltage inverter systems and especially focuses on light load areas in home appliances. The validity of the proposed strategy has been verified by experimental results. Three methods are combined to achieve good efficiency of home appliances with a variable dc-link voltage inverter system.

A 2.2 KW dynamo system is used to check the system efficiency. Finally, a maximum 6.5% efficiency improvement can be achieved using proposed system.

References

  1. Liu, Xudan, et al. “A high-efficiency single-phase AC/DC converter with enabling window control and active input bridge.” Power Electronics, IEEE Transactions on 27.6 (2012): 2912-2924. https://doi.org/10.1109/TPEL.2011.2178267
  2. Lim, Shu Fan, and Ashwin M. Khambadkone. “Nonlinear inductor design for improving light load efficiency of boost PFC.” Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE. IEEE, 2009.
  3. Su, Jen-Ta, and Chih-Wen Liu. “A Novel Phase-Shedding Control Scheme for Improved Light Load Efficiency of Multiphase Interleaved DC-DC Converters.” IEEE transactions on power electronics 28.10 (2013): 4742-4752. https://doi.org/10.1109/TPEL.2012.2233220
  4. Kwon, Young Ahn, and Sang Kyoon Kim. “A high-performance strategy for sensorless induction motor drive using variable link voltage.” Power Electronics, IEEE Transactions on 22.1 (2007): 329-332. https://doi.org/10.1109/TPEL.2006.887178
  5. IEC EN 61000-3-2 standard. http://en.wikipedia.org/wiki/IEC_EN_61000-3-2
  6. Sung Pil Ha, Jung Hyo Lee, Jung Pill Hwang, Jun Hyuk Choi, Chung Yuen Won. “Two Phase Interleaved Bidirectional DC-DC Converter for Electric Vehicle using Variable dc-Link Voltage.” 2012 IEEE Vehicle Power and Propulsion Conference, Oct. 9-12, 2012, Seoul, Korea.
  7. Byung-Gu Kang, Chong-Eun Kim, Dong-Kwan Kim, Gun-Woo Moon. “Hirnlgh Power Density Cascade Buck-Boost PFC for High Input Voltage.” KIPE Transactions on Power Electronics Annual Conference 2015.07, 247-248.
  8. M. C. Ghanem, K. Al-Haddad, and G. Roy, “A new control strategy to achieve sinusoidal line current in a cascade buck-boost converter,” IEEE Trans. Ind. Electron., vol. 43, pp. 441-449, June 1996. https://doi.org/10.1109/41.499817