References
- Lin D, Li Q, Li W, Duckmanton N, Swain M (2010) Mandibular bone remodelling induced by dental implant. J Biomech 19:287-293
- Lee JH, Frias V, Lee KW, Wright RF (2005) Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 94:377-381 https://doi.org/10.1016/j.prosdent.2005.04.018
- Lehman H, Casap N (2014) Rapid-prototype titanium bone forms for vertical alveolar augmentation using bone morphogenetic protein-2: design and treatment planning objectives. Int J Oral Maxillofac Implants 29(2):e259-e254 https://doi.org/10.11607/jomi.te62
- Jensen OT, Lehman H, Ringeman JL, Casap N (2014) Fabrication of printed titanium shells for containment of BMP-2 composite graft materials for alveolar bone reconstruction. Int J Oral Maxillofac Implants 29(1):e103-e105 https://doi.org/10.11607/jomi.te48
- Renouard F, Nisand D (2006) Impact of implant length and diameter on survival rates. Clin Oral Imp Res 17(2):35-51 https://doi.org/10.1111/j.1600-0501.2006.01349.x
- Olate S, Lyrio MCN, Moraes M, Mazzonetto R, Moreira RWF (2010) Influence of diameter and length of implant on early dental implant failure. J Oral Maxillofac Surg 68:414-419 https://doi.org/10.1016/j.joms.2009.10.002
- Barikani H, Rashtak S, Akbari S, Fard MK, Rokn A (2014) The effect of shape, length and diameter of implants on primary stability based on reasonance frequency analysis. Dent Res J 11(1):87-91
- Velde T, Collaert B, Sennerby L, Bruyn H (2010) Effect of implant design on preservation of marginal bone in the mandible. Clin Implant Dentist Related Res 12(2):134-141
- Chung JM, Jo KH, Lee CH, Yu WJ, Lee KB (2009) Finite element analysis of peri-implant bone stress influenced by cervical module configuration of endosseous implant. J Kor Acad Prosthodont 47(4):394-404 https://doi.org/10.4047/jkap.2009.47.4.394
- Park JW, Kim SG, Choi DW, Choi MR, Yoon YJ, Park JW et al (2012) Study of a "wing-type" implant on stress distribution and bone resorption at the alveolar crest. J Korea Acad Oral Maxillofac Surg 38(6):337-342 https://doi.org/10.5125/jkaoms.2012.38.6.337
- Tae Sun Lee (2014) Effects of the structural change of the implant on the stress distribution to the surrounding tissues and the stability of the implant. Thesis of Hallym University. June:1-28
- Gaviria L, Salcido JP, Guda T, Ong JL (2014) Current trends in dental implants. J Korean Assoc Oral Maxillofac Surg 40:50-60 https://doi.org/10.5125/jkaoms.2014.40.2.50
- Albrektsson T, Wennerberg A (2005) The impact of oral implants-past and future, 1966-2042. J Can Dent Assoc 71(5):327-327
- Jimbo R, Halldin A, Janda M, Wennerberg A, Vandeweghe S (2013) Vertical fracture and marginal bone loss of internal-connection implants: a finite element analysis. Int J Oral Maxillofac Implants 28:e171-e176 https://doi.org/10.11607/jomi.3052
- Assuncao WG, Gomes EA, Barao VAR, Sousa EAC (2009) Stress analysis in simulation models with or without implant threads representation. Int J Oral Maxillofac Implants 24:1040-1044
- Marce-Nogue JM, Walter A, Gil L, Puigdollers AC (2013) Finite element comparison of 10 orthodontic microscrews with different cortical bone parameters. Int J Oral Maxillofac Implants 28:e177-e189 https://doi.org/10.11607/jomi.2447
- Simsek B, Erkmen E, Yilmaz D, Eser A (2006) Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: a 3D finite element analysis. Medical Eng Physics 28:199-213 https://doi.org/10.1016/j.medengphy.2005.04.025
- Qian L, Todo M, Matsushita Y, Koyano K (2009) Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone system: finite element analysis. Int J Oral Maxillofac Implants 24:877-886
- Chang PK, Chen YC, Huang CC, Lu WH, Chen YC, Tsai HH (2012) Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study. Int J Oral Maxillofac Implants 27:e96-e102
Cited by
- Stress evaluation of different implant lengths on atrophic edentulous mandibles with fixed full-arch implant-supported prosthesis: a finite element analysis vol.24, pp.4, 2016, https://doi.org/10.1080/10255842.2020.1817406