DOI QR코드

DOI QR Code

CT Findings of Foreign Body Reaction to a Retained Endoloop Ligature Plastic Tube Mimicking Acute Appendicitis: A Case Report

  • Ahn, Jae Hong (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine) ;
  • Kang, Chae Hoon (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine) ;
  • Choi, Soo-Jung (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine) ;
  • Park, Man Soo (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine) ;
  • Jung, Seung Mun (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine) ;
  • Ryu, Dae Shick (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine) ;
  • Shin, Dong Rock (Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine)
  • 투고 : 2016.01.07
  • 심사 : 2016.04.11
  • 발행 : 2016.07.01

초록

Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis.

키워드

참고문헌

  1. Gawande AA, Studdert DM, Orav EJ, Brennan TA, Zinner MJ. Risk factors for retained instruments and sponges after surgery. N Engl J Med 2003;348:229-235 https://doi.org/10.1056/NEJMsa021721
  2. Kaiser CW, Friedman S, Spurling KP, Slowick T, Kaiser HA. The retained surgical sponge. Ann Surg 1996;224:79-84 https://doi.org/10.1097/00000658-199607000-00012
  3. Kalovidouris A, Kehagias D, Moulopoulos L, Gouliamos A, Pentea S, Vlahos L. Abdominal retained surgical sponges: CT appearance. Eur Radiol 1999;9:1407-1410 https://doi.org/10.1007/s003300050858
  4. Enker WE, Martz JE, Picon A, Wexner SD, Fleshman JW Jr, Koulos J, et al. An incremental step in patient safety: reducing the risks of retained foreign bodies by the use of an integrated laparotomy pad/retractor. Surg Innov 2008;15:203-207 https://doi.org/10.1177/1553350608321105
  5. Choi BI, Kim SH, Yu ES, Chung HS, Han MC, Kim CW. Retained surgical sponge: diagnosis with CT and sonography. AJR Am J Roentgenol 1988;150:1047-1050 https://doi.org/10.2214/ajr.150.5.1047
  6. Porter KK, Bailey PD, Woods R, Scott WW Jr, Johnson PT. Retained surgical item identification on imaging studies: a training module for radiology residents. Int J Comput Assist Radiol Surg 2015;10:1803-1809 https://doi.org/10.1007/s11548-015-1154-9