DOI QR코드

DOI QR Code

Improving Performance of Crimp Signal Analysis by Falling Edge Alignment and Parameter Error Estimation in CFM

CFM에서 하강 에지 정렬과 파라미터 에러 평가에 의한 크림프 시그널 분석 성능 향상

  • ;
  • 강태삼 (건국대학교 항공우주정보시스템공학과) ;
  • 한충권 ((주)한국마스터) ;
  • 박정근 (건국대학교 항공우주정보시스템공학과)
  • Received : 2016.03.22
  • Accepted : 2016.07.22
  • Published : 2016.09.01

Abstract

A Crimp Force Monitor (CFM) is equipment for detecting crimp errors by analyzing crimp signals obtained from force and strain sensors. The analysis is commonly performed by aligning a measured crimp signal with a reference signal and comparing their difference. Current analysis methods often suffer from wrong alignments that result in false negative detections. This paper presents a new crimp signal analysis method in CFM. First, a falling edge alignment is proposed that matches falling edges of the measured and the reference signals by minimizing the absolute difference summation. Second, a signal parameter error is introduced to evaluate the crimp quality difference between the measured signal and the reference. For calculating the signal parameter error, part of a signal is identified and divided into several regions to maximize the signal parameter errors. Experiments showed that the proposed method can improve the signal alignment and accurately detect bad crimps especially with the strain sensor.

Keywords

References

  1. "Wire Termination Uses and Method," Assembly Magazine, Aug. 2003.
  2. Molex, Quality Crimping Handbook, Sep. 2003.
  3. G. Villeneuve, D. Kulkarni, P. Bastnagel, and D. Berry, "Dynamic finite element analysis simulation of the terminal crimping process," Proc. 42nd IEEE Holm Conf. on Elec. Contacts, Chicago, pp. 156-172, 1996.
  4. Jim Camillo, "Assessing crimp quality," Assembly Magazine, Jul. 2012.
  5. R. Klemmer, B. Crane, and S. Wright "Crimp height monitor," US Patent 5092026 A, Apr. 1991.
  6. M. D. Strong and M. A. Yeomans, "Method of determining the crimp height of a crimped electrical connection," US Patent 5123165 A, Mar. 1991.
  7. Molex, Crimp Force Monitor Instruction Manual, 2013.
  8. True Soltec., Ltd, Operation Manual CFM-MX20N (2 Channel), 2005.
  9. K.-H. Gloe and H. Biehl, "Crimped connector quality control method apparatus," US Patent 5271254 A, May 1993.
  10. M. D. Strong and M. A. Yeomans, "Method of evaluating a crimped electrical connection," US Patent 5937505 A, Aug. 1995.
  11. Schmid, Tobias, "Development of a new crimp quality monitoring system for manually operated tools," Master Thesis, University of Limerick, Ireland, Aug. 2013.
  12. M. D. Strong and M. A. Yeomans, "Method of determining the quality of a crimped electrical connection," US Patent 5197186 A, May 1990.
  13. S. Aurecianus, "Crimp force monitoring equipment design using mbed microcontroller and 16 bit AD converter," Master Thesis, Dept. of Aerospace Engineering and Information Engineering, Konkuk University, 2014.
  14. S. Aurecianus, "Crimp process signal alignment method utilizing absolute differences summation to determine crimp quality," Proc. of 2014 Information and Telecommunication Facility Engineering, 2014.
  15. Kamen, Edward W. and Heck, Bonnie S. Fundamentals of Signals and Systems Using the Web and MATLAB, Prentice Hall, 2007.
  16. D. Shin, B.-J. Jin, and J.-K. Yoon, "Inspection system of electric vehicle battery plate using image processing," Journal of Institute of Control, Robotics and Systems (in Korean), vol. 20, no. 7, pp. 718-723, Jul. 2014. https://doi.org/10.5302/J.ICROS.2014.13.1982
  17. G. Kim, Y. H. Park, J.-S. Park, and J.-S. Cho, "Auto parts visual inspection in severe changes in the lighting environment," Journal of Institute of Control, Robotics and Systems (in Korean), vol. 21, no. 12, pp. 1109-1114, Dec. 2015. https://doi.org/10.5302/J.ICROS.2015.15.0134