Abstract

The flexural strength of circular concrete-filled tubes (CCFT) can be estimated by several codes such as ACI, AISC, and Eurocode 4. In AISC and Eurocode, two methods are recommended, which are the strain compatibility method (SCM) and the plastic stress distribution method (PSDM). The SCM of AISC is almost the same as the SCM of the ACI method, while the SCM of Eurocode is similar to the ACI method. Only the assumption of the compressive stress of concrete is different. The PSDM of Eurocode approach is also similar to the PSDM of AISC, but they have different definitions of material strength. The PSDM of AISC is relatively easier to use, because AISC provides closed-form equations for calculating the flexural strength. However, due to the complexity of calculation of circular shapes, it is quite difficult to determine the flexural strength of CCFT following other methods. Furthermore, all these methods give different estimations. In this study, an effort is made to review and compare the codes to identify their differences. The study also develops a computing program for the flexural strength of circular concrete filled tubes under pure bending that is in accordance with the codes. Finally, the developed computing algorithm, which is programmed in MATLAB, is used to generate design aid graphs for various steel grades and a variety of strengths of steel and concrete. These design aid graphs for CCFT beams can be used as a preliminary design tool.

Keywords

Acknowledgement

Grant : BK21플러스

Supported by : 서울대학교

References

  1. ACI 318 (2014), Building code requirements for structural concrete and commentary, American Concrete Institute, Farmington Hills, MI, USA.
  2. AISC (2011), Steel construction manual, American Institute of Steel Construction, Chicago, IL, USA.
  3. AISC (2011), Design examples V14.2, American Institute of Steel Construction, Chicago, IL, USA.
  4. Eurocode 2 (2004), Design of concrete structures, Part 1.1: General rules and rules for building, European Committee for Standardization, Brussels, Belgium.
  5. Eurocode 4 (2004), Design of composite steel and concrete structures, Part 1.1: General rules and rules for building, European Committee for Standardization, Brussels, Belgium.
  6. Geschwindner, L.F. (2010), "Discussion of reinforced concrete members under flexure and combined flexure and direct compression", Eng. J., 47(2), 483-498.
  7. Leon, R.T. and Hajjar, J.F. (2008), "Limit state response of composite columns and beam-columns part II: Application of design provisions for the 2005 AISC specification", Eng. J., 45(1), 21-46.
  8. Lee, C.-H., Kang, T.H.-K., Kim, S.-Y. and Kang, K. (2016), "Strain compatibility method for the design of short rectangular concrete-filled tube columns under eccentric axial loads", Constr. Bldg. Mat., 121, 143-153. https://doi.org/10.1016/j.conbuildmat.2016.05.145
  9. Lee, J.D., Yoon, J.K. and Kang, T.H.-K. (2016), "Combined half precast concrete slab and post-tensioned slab topping system for basement parking structures", J. Struct. Integr. Maint., 1(1), 1-9. https://doi.org/10.1080/24705314.2016.1153281
  10. Kang T.H.-K., Wallace, J.W. and Elwood, K.J. (2008), "Nonlinear modeling of flat-plate systems", J. Struct. Eng., 135(2), 147-158.
  11. Kim, J.-W., Lee, C.-H. and Kang, T.H.-K. (2014), "Shearhead reinforcement for concrete slab to concretefilled tube column connection", ACI Struct. J., 111(3), 629-638.
  12. Probst, A.D., Kang, T.H.-K., Ramseyer, C. and Kim, U. (2010), "Composite flexural behavior of full-scale concrete-filled tubes without axial loads", J. Struct. Eng., 136(11), 1401-1412. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000241
  13. Yang, K.-H. and Kang, T.H.-K. (2011), "Equivalent strain distribution factor for unbonded tendon stress at ultimate", ACI Struct. J., 108(2), 217-226.
  14. Kang, L., Leon, R.T. and Lu, X. (2015), "Shear strength analyses of internal diaphragm connections to CFT columns", Steel Compos. Struct., 18(5), 1083-1101. https://doi.org/10.12989/scs.2015.18.5.1083
  15. Manikandan, P. and Sukuma, S. (2016), "Effect of stiffened element and edge stiffener in strength and behaviour of cold formed steel built-up beams", Adv. Comput. Des., 1(2), 207-220. https://doi.org/10.12989/ACD.2016.1.2.207

Cited by

  1. Flexural Testing of Circular Concrete-Filled Tubes without Axial Forces vol.115, pp.2, 2018, https://doi.org/10.14359/51701134
  2. Bending and Shear Behaviour of Waste Rubber Concrete-Filled FRP Tubes with External Flanges vol.13, pp.15, 2021, https://doi.org/10.3390/polym13152500