Abstract

Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

Keywords

References

  1. Groten M, Axmann D, Probster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent, 83, 40-49, 2000. https://doi.org/10.1016/S0022-3913(00)70087-4
  2. Harris IR, Wickens JL. A comparison of fit of spark-eroded titanium copings and cast gold alloy copings. Int J Pros-thodont, 7, 348-355, 1994.
  3. Kim KB, Lee GT, Kim HY, Kim JH. The influence of different gypsum materials on the accuracy from complete arch digital impression. J Dent Hyg Sci, 12, 617-623, 2012.
  4. Kim JH, Kim WS, Kim KB. Evaluation of marginal gap of fixed dental prostheses fabricated by soft metal material using dental CAD/CAM. J Dent Hyg Sci, 14, 349-355, 2014. https://doi.org/10.17135/jdhs.2014.14.3.349
  5. Kokubo Y, Nagayama Y, Tsumita M, Ohkubo C, Fukushima S, Vult von Steyern P. Clinical marginal and internal gaps of in-ceram crowns fabricated using the GN-I system. J Oral Rehabil, 32, 753-758, 2005. https://doi.org/10.1111/j.1365-2842.2005.01506.x
  6. Luthardt RG, Bornemann G, Lemelson S, Walter MH, Huls A. An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont, 17, 680-685, 2004.
  7. McLean JW, von Frauenhofer JA, The estimation of cement film thickness by an in vivo technique. Br Dent J, 131, 107-111, 1971. https://doi.org/10.1038/sj.bdj.4802708
  8. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J, 28, 44-56, 2009. https://doi.org/10.4012/dmj.28.44
  9. Moldovan O, Rudolph H, Quaas S, Bornemann G, Luthardt RG. Internal and external fit of CAM-made zirconia bridge frameworks - a pilot study. Dtsch Zahnaztl Z, 61, 38-42, 2006.
  10. Ostlund LE. Cavity design and mathmatics: their effect on gaps at the margins of cast restorations. Oper Dent, 10, 122-137, 1985.
  11. Reich S, Kappe K, Teschner H, Schmitt J. Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci, 116, 579-584, 2008. https://doi.org/10.1111/j.1600-0722.2008.00580.x
  12. Shillingburg HT Hobo S, Fisher DW. Preparation design and margin distortion in porcelain-fused-to-metal restorations. J Prosthet Dent, 29, 276-284, 1973. https://doi.org/10.1016/0022-3913(73)90007-3
  13. Tuntiprawon M, Wilson PR. The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J, 40, 17-21, 1995. https://doi.org/10.1111/j.1834-7819.1995.tb05607.x
  14. Wettstein F, Sailer I, Roos M, Hammerle CH. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. J Oral Sci, 116, 272-279, 2008. https://doi.org/10.1111/j.1600-0722.2008.00527.x