References
- Ho L, Hoefel D, Bock F, Saint CP, Newcombe G. Biodegradation rates of 2-methylisoboneol and geosmin through sand filters and in bioreactors. Chemosphere. 2007;66(11):2210-2218. https://doi.org/10.1016/j.chemosphere.2006.08.016
- Vorosmarty CJ, McLntyre PB, Gessner MO, Dudgeon D, Prusevich A, Green P, et al. Global threats to human water security and river biodiversity. Nature. 2007;467(7314):555-561.
- Robertson RF, Hammond A, Jauncey K, Beveridge MCM, Lawton LA. An investigation into the occurrence of geosmin responsible for earthy-musty taints in UK farmed rainbow trout, Onchorhynchus mykiss. Aquacul-ture. 2006;259(8):153-163. https://doi.org/10.1016/j.aquaculture.2004.11.046
- Gerber NN, Lechevalier HA. Geosmin, an Earthy-smelling substance isolated from Actinomycetes. Appl En-viron Microbiol. 1965;13(6):935-938.
- Madaeni SS, Fane AG, Grohmann GS. Virus removal from water and wastewater using membrane. J Mem-brane Sci. 1995;102(1):65-75. https://doi.org/10.1016/0376-7388(94)00252-T
- Taedosiu CC, Kennedy MD, Straten HA, Schippers JC. Evaluation of secondary refinery effluent treatment using ultrafiltration membranes. Water Res. 1999:33(9):2172-2180. https://doi.org/10.1016/S0043-1354(98)00433-3
- Asami M, Aizawa T, Morioka T, Nishijima W, Tabata A, Magara Y. Bromate removal during transition from new granular activated carbon (GAC) to biological activated carbon (BAC). Water Res. 1999:33(12):2797-2804. https://doi.org/10.1016/S0043-1354(98)00504-1
- Scholz M, Martin RJ. Ecological equilibrium on biological activated carbon. Water Res. 1997;31(12):2959-2968. https://doi.org/10.1016/S0043-1354(97)00155-3
- Walter WJ, Pirbazari M, Melson GL. Biological growth on activated carbon: an investigated by scanning electronic ROS copy. Environ Sci Technol. 1978;12(7):817-819. https://doi.org/10.1021/es60143a005
- Moll DM, Summers RS, Fonseca AC, Matheis W. Impact of temperature on drinking water biofilter perfor-mance and microbial community structure. Environ Sci Technol. 1999;33(14):2377-2382. https://doi.org/10.1021/es9900757
- Lanmark J, Storey MV, Ashbolt NJ, Stenstrom TA. Artificial groundwater treatment: biofilm activity and organic carbon removal performance. Water Res. 2004;38(3):740-748. https://doi.org/10.1016/j.watres.2003.10.021
- Chestnutt TE, Bach MT, Mazyck DW. Improvement of thermal reactivation of activated carbon for the removal of 2-emthylisoborneol. Water Res. 2007;41(1):79-86. https://doi.org/10.1016/j.watres.2006.09.010
- Dussert B, Van Stone G. The biological activated carbon process for water purification. Water Eng Manage. 1994;141(21):22-24.
- Sevais P, Billen G, Bouillot P, Benezet M. A pilot study of biological GAC filtration in drinking water treat-ment. J Wat Sup. 1992;41(3):163-168.
- Park S, Lee S, Sin S, Jun C, Kim C. Variation of pollutant removal efficiency and backwashing effect of BAC basin in advanced water treatment processes. J Kor Soc Environ Eng. 2008;30(1):45-53.
- Carlson KH, Amy GL. Ozone and biofiltration optimization for multiple objective. J AWWA. 2001;93(1):88-98.
- Park J, Takizawa S, Katayama H, Ohgaki S. Biofilter pretreatment for the control of microfiltration mem-brane fouling. Water Sci Tech: Water Supply. 2002; 2(2):193-199.
- Son HJ, Park HK, Lee SA, Jung EY, Jung CW. The characteristics of microbial community for biological activated carbon in water treatment plant. J Kor Soc Environ Eng. 2005;27(11):1311-1320.
- Taedosiu CC, Kennedy MD, Straten HA, Schippers JC. Evaluation of secondary refinery effluent treatment using ultra filtration membranes. Water Res. 1999;33(9):2172-2180. https://doi.org/10.1016/S0043-1354(98)00433-3
- Cho J, Lim J, Baek D, Lee SH, Lee IS, Lee H, et al. Development of techniques for evaluating the virus re-moval rate using adenovirus. J Korean Soc Water & Wastewater. 2015;29(6):633-641. https://doi.org/10.11001/jksww.2015.29.6.633
- Klimenko N, Winter-Nielsen M, Smolin S, Nevynna L, Sydorenko J. Role of the physicochemical factors in the purification process of water from surface-active matter by biosorption. Water Res. 1992;36(20):231-241.
- Ridgway HF, Olsan BH. Scanning electron microscope evidence for bacterial colonization of drinking water distribution system. Appl Environ Microbiol. 1981;21(3):274-287.
- Son HJ, Yoo SJ, Roh JS, Yoo PJ. Biological activated carbon (BAC) process in water treatment. J Kor Soc Environ Eng. 2009;31(4):308-322.
- Baek D, Lim J, Cho Y, Ahn YT, Lee H, Park D, et al. Investigation of geosmin removal efficiency by micro-organism isolated from biological activated carbon. J Korean Soc Water & Wastewater. 2015;29(1):47-55. https://doi.org/10.11001/jksww.2015.29.1.047
Cited by
- UV 전처리 유무에 따른 입상활성탄의 세균 생체량 및 군집 구조 비교 vol.17, pp.12, 2016, https://doi.org/10.5392/jkca.2017.17.12.064