참고문헌
- L. G. Christophorou, J. K. Olthoff and R. J. Van Brunt, "Sulfur Hexafluoride and the Electric Power Industry", IEEE Electr. Insul. Mag., Vol. 13, No. 5, pp. 20-24, 1997. https://doi.org/10.1109/57.620514
-
H. Toyota, S. Matsuoka, and K. Hidaka, "Measurement of Sparkover Voltage and Time Lag Characteristics in
$CF_3I-N_2$ and$CF_3I$ -Air Gas Mixtures by using Steep-Front Square Voltage", Electr. Eng. Jpn., Vol. 157, No. 2, pp. 1-7, 2006. -
T. Rokunohe, Y. Yagihashi, K. Aoyagi, T. Oomori and F. Endo, "Developrrent of
$SF_6$ -free 72.5 kV GIS", IEEE Trans. Power Deliv., Vol. 22, No. 3, pp. 1869-1876, 2007. https://doi.org/10.1109/TPWRD.2007.899273 - H. Saito, K. Nagatake, H. Komatsu, Y. Takeshi, Y. Matsui, k. Katslmata, and M. Sakaki, "Development of 72/84kV Dry Air-Insulated Dead Tank VCB", Electr. Eng. Jpn., Vol. 177, No. 1, pp. 1-10 2011.
-
Y. Hoshina, M. Sato, M. Shiiki, M. Hanai and E. Kaneko, "Lightning impulse breakdown characteristics of
$SF_6$ alternative gases for gas-insulated switchgear", IEE Proc.-Sci. Meas. Technol., Vol. 153, No. 1, pp. 1-6, 2006. https://doi.org/10.1049/ip-smt:20050007 -
大陽日酸東関東株式会社, "六フッ化硫(
$SF_6$ )の回収技術", J . Vac. Soc. Jpn, Vol. 52, No. 7, pp. 397-399, 2009. https://doi.org/10.3131/jvsj2.52.397 -
H. Okubo, A. Beroual, "Recent Trend and Future Perspectives in Electrical Insulation Techniques in Relation to Sulfur Hexafluoride (
$SF_6$ ) Substitutes for High Voltage Electric Power Equipment," IEEE Electr. Insul. Mag., Vol. 27, No. 2, pp. 34-42, 2011. - T. Takuma, O. Yamamoto and S. Hamada, "GASES AS A DIELECTRIC," Gaseous Dielectrics X, pp. 195-204, 2004.
-
N. H. Malik and A. H. Qureshi, "BREAKDOWN GRADIENTS IN
$SF_6{^-}N_2$ ,$SF_6{^-}AIR$ ,$SF_6{^-}CO_2$ MIXTURES", IEEE Trans. Electr. Insul., Vol. EI-15, No. 5, pp. 413-418, 1980. https://doi.org/10.1109/TEI.1980.298335 -
T. Watanabe and T. Takuma, "The Breakdown Voltage and Discharge Extension of Long Gaps in Nitrogen-
$SF_6$ and Air-$SF_6$ Gas Mixtures", J. Appl. Phys., Vol. 48, pp. 3281-3287, 1977. https://doi.org/10.1063/1.324208 -
X. Q. Qiu, I. D. Chalmers, P. Coventry, "A Study of Alternative Insulating Gases to
$SF_6$ ", J. Phys. D: Appl. Phys., Vol. 32, pp. 2918-2922, 1999. https://doi.org/10.1088/0022-3727/32/22/314 -
H. Okubo, T. Yamada, K. Hatta, N. Hayakawa, S. Yuasa and S. Okabe, "Partial discharge and breakdown mechanisms in ultra-dilute
$SF_6$ and PFC gases mixed with$N_2$ gas", J. Phys. D: Appl. Phys., Vol. 35, pp. 2760-2765, 2002. https://doi.org/10.1088/0022-3727/35/21/311 - L. G. Christophorou, J. K. Olthoff and D. S. Green, "A Search for Possible Universal-Application Gas Mixtures", Gaseous Dielectrics VIII, pp. 361-366, 1998.
-
T. Rokunohe, Y. Yagihashi, F. Endo, and T. Oomori, "Fundamental Insulation Characteristics of Air,
$N_2$ ,$CO_2$ ,$N_2/O_2$ and$SF_6/N_2$ Mixed Gases", Electr. Eng. Jpn., Vol. 155, No. 3, pp. 9-17, 2006. -
J. H. Seok, J. H. Beak, D. Y. Lim, S. Bae, K. C. Kim and W. Z. Park, "A Study on Characteristics of Insulation Breakdown and Surface Discharge by the Mixing Ratio of Dry
$Air/O_2$ gas mixtures", J Korean Inst. IIIum. Electr. Install. Eng., Vol. 29, No. 6, pp. 49-57, 2015. - J. H. Mason, "Discharges", IEEE Trans. Electr. Insul, Vol. EI-13, No. 4, pp. 211-238, 1978. https://doi.org/10.1109/TEI.1978.298074
- D. Y. Lim and S. Bae, "Study on Oxygen/Nitrogen Gas Mixtures for the Surface Insulation Performance in Gas Insulated Switchgear", IEEE Trans. Dielectr. Electr. Insul., Vol. 22, No. 3, pp. 1567-1576, 2015. https://doi.org/10.1109/TDEI.2015.7116352
- L. G. Christophorou and L. A. Pinnaduwage, "Basic Physics of Gaseous Dielectrics", IEEE Trans. Dielectr. Electr. Insul., Vol. 25, No. 1, pp. 55-74, 1990. https://doi.org/10.1109/14.45234
- S. Pancheshnyi, "Effective ionization rate in nitrogen-oxygen mixtures", J. Phys. D: Appl. Phys., Vol. 46, No. 15, 155201, 2013. https://doi.org/10.1088/0022-3727/46/15/155201
-
G. Wormeester, S. Pancheshnyi, A. Luque, S. Nijdam and U. Ebert, "Probing photo-ionization: simulations of positive streamers in varying
$N_2:O_2{^-}mixtures$ ", J. Phys. D: Appl. Phys., Vol. 43, 505201, pp. 1-13, 2010. -
J. K. Olthoff, R. J. Van Brunt, Y. Wang, R. L. Champion and L. D. Doverspike, "Collisional Electron Detachment and Decomposition Rates of
$SF_6{^-}$ , SF5- and F- in$SF_6$ : Implications for Ion Transport and Electrical Discharges", J. Chem. Phys. Vol. 91, pp. 2261-2268, 1989. https://doi.org/10.1063/1.457646 -
R. Morrow, "Theory of electrical corona in
$SF_6$ ", Nucl. Instr. and Meth. in Phys. Res. A 382, pp. 57-65, 1996. https://doi.org/10.1016/S0168-9002(96)00504-9 -
H. Kojima, O. Kinoshita, N. Hayakawa, F. Endo, H. Okubo, M. Yoshida and T. Ogawa, "Brekdown Characteristics of
$N_2O$ Gas Mixtures for Quasi Uniform Electric Field under Lightning Impulse Voltage", IEEE Trans. Dielectr. Electr. Insul., Vol. 14, No. 6, pp. 1492-1497, 2007. https://doi.org/10.1109/TDEI.2007.4401233 -
D. Y. Lim, E. H. Choi, S. T. Choi, B. J. Choi, K. S. Lee and S. Bae, "Surface Flashover Characteristics on Poor Contact in
$N_2/O_2$ Mixture Gas under Non-Uniform Field", J Korean Inst. IIIum. Electr. Install. Eng., Vol. 29, No. 8, pp. 63-69, 2015.