초록

Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

키워드

참고문헌

  1. ISO 9869-1 - Building elements - In-situ measurement of thermal resistance and thermal transmittance - Part 1 : Heat flow meter method 2014(E)
  2. Tanaka JUN, Takeda MASASHI, "Building Environmental Engineering", p. 191-192, 2014
  3. Giorgio Ficco, Fabio Iannettaa, Elvira Ianniello, Francesca Romana d'Ambrosio Alfano, Marco Dell'Isola, "U-value in situ measurement for energy diagnosis of existing buildings", Energy and Buildings, Volume 104, 2015
  4. Pier Giorgio Cesaratto, Michele De Carli, "A measuring campaign of thermal conductance in situ and possible impacts on net energy demand in buildings" Energy and Buildings, Volume 59, 2013
  5. Xuan CHENG, Shinsuke KATO, Kyosuke HIYAMA, Sihwan LEE, "The Technological Investigation of Wall Thermal performance Diagnosis", Review on activities of support corps in Tokyo during the 2011 Great East Japan Earthquake, 2011
  6. Sihwan LEE, Shinsuke KATO, "Feasibility Study of In-Situ Measurement Method Using The Infrared Camera To measure U-value of Walls on Residential House Installed An convection Stove", J. Environ. Eng., AIJ, Vol. 661
  7. Gyeongseok CHOI, Jangyeul SOHN, "Thermal Performance Evaluation of Apartment Housing Using Infra-red Camera." The Society Of Air-Conditioning And Refrigerating Engineers Of Korea, Vol. 22(6), 404-412
  8. Jeonggook KIM, Jonghun KIM, Hakgeon JEONG, Cheolyong JANG, Junghun LEE, Doosam SONG, "An analysis of apartment reference model for Low-income households support methods." The Korean Society for Energy, Vol. 24

피인용 문헌

  1. A Study on a thermal performance evaluation of interior surface temperature measurement in an apartment side wall vol.17, pp.3, 2018, https://doi.org/10.15250/joie.2018.17.3.224