DOI QR코드

DOI QR Code

Fractional efficiency of Nanomaterials for the High efficiency respiratory filters

고효율 호흡보호구의 나노물질 입경별 제거 효율

  • Received : 2016.08.25
  • Accepted : 2016.09.30
  • Published : 2016.09.30

Abstract

Controlling exposures to occupational hazards is important for protecting workers. Certified facepiece respirators are recommended when engineering controls do not adequately prevent exposures to airborne nanomaterials. The objective of this study is to carry out the experimental performance test to investigate the fractional efficiencies of the filter media for two grades of facepiece respirators. Experimental performance evaluations were carried out for the test NaCl particles and silver nanoparticles. For media of respirator filter, the penetration of NaCl particles was less than 5% and the most penetrating particle size occurred at about 40 nm. For silver nanoparticles, the most penetrating particle size was about 20nm with higher efficiency than those of NaCl particles. Charge characteristics of airborne nanoparticles is important because the media of respirator filter is made by the electret filter media.

본 연구에서는 호흡용 보호구 필터의 나노물질에 대한 여과특성을 측정하기 위해서 소금(NaCl)과 은나노입자(Ag)를 대상으로 입경별 집진효율을 평가하였다. 호흡용 보호구 필터는 특급 방진마스크와 1급 방진마스크의 두 가지 안면부 여과식 방진마스크인 사용하였고, 마스크의 배기밸브 부분을 제외한 필터 여재 부분을 직경 47 mm로 잘라내어 필터홀더에 부착하여 입경별 입자제거효율을 시험하였다. 시험입자는 일반적으로 시험 입자로 사용되는 소금입자는 분무형 입자발생장치를 사용하여 발생하였고 중화기를 통과시켜 입자의 하전특성을 볼츠만 분포로 만들어 공급하였다. 은나노입자의 경우, 기화-응축 방법을 이용한 금속나노입자 생성방법인 ISO10801 방법을 사용하였다. 작업장의 은나노입자의 고농도 노출을 모사하기 위해, 중화기를 통과하지 않은 나노입자를 시험입자로 사용하였다. 은나노입자의 경우 소금입자로 만들기 어려운 20nm 이하의 입자를 안정적으로 효과적으로 만들어 시험에 적용하였고, 나노 크기에서도 매우 안정적인 데이터를 확보할 수 있었다. 1급 마스크 필터와 특급 마스크 필터에 대한 소금입자의 평가에서, 입경별 최소효율이 30~50nm 사이에서 나타나는 특성은 기존 연구와 비슷한 결과를 얻었다. 반면, 은나노입자의 경우 1급 마스크 필터와 특급 마스크 필터 모두에서 비슷한 크기의 소금 입자와 비교할 때 높은 효율을 나타냈다. 이것은 소금 입자의 경우 중화기를 통과시켜 시험입자로 사 용한 반면, 은나노입자의 경우 중화기를 통과시키지 않았기 때문이다. 본 연구에서는 작업장에서 은나노 입자가 고농도로 노출될 경우를 모사하여, 기화-응축에 의한 방법의 은나노입자 발생장치를 사용하였는데, 이 때 상대적으로 높게 대전된 입자들이 많이 만들어진다(Jung et al., 2006). 이로 인해, 정전필터인 마스크 필터의 포집 효과가 상대적으로 크기 때문에, 입경별 효율이 높아진 것으로 생각된다. 본 연구에서 평가한 1급 및 특급 방진마스크 여재의 최소 포집효율은 유럽 EN 149 기준인 95 LPM 유량 기준을 만족하는 것으로 나타났지만, 이것은 여재에 대한 평가 결과로, 실제 마스크에 대해서는 여재의 구조적인 불균일성이나 마스크를 착용하는 과정에서 밀착이 되지 않아 누출될 가능성은 마스크 사용에 고려되어야 한다. 불시에 발생할 수 있는 작업장 내 안전사고의 예방을 위하여 적절한 보호구의 선택과 올바른 착용 및 유지관리가 필요할 것으로 생각된다.

Keywords

References

  1. 노동부(2008), 보호구 의무안전인증 고시, 노동부고시 제2008 - 77호 (2008. 12. 3)
  2. Han D, (2011), Are Particulate Filtering Respirators Available in Korea Efficient for Nanoparticles?, J Korean Soc Occup Environ Hyg, 21(1), 62-71
  3. ISO10801, (2010), Nanotechnologies-Generation of Metal Nanoparticles with the Evaporation/Condensation Method for Inhalation Toxicity Testing.
  4. Ji, J.H., Bae, G. N., Kang, S. H., and Hwang, J. H. (2003), "Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles," J. Aerosol Sci., 34, pp. 1493-1504. https://doi.org/10.1016/S0021-8502(03)00103-4
  5. Ji, J.H., Jung, J.H., Kim, S.S, Yoon, J.U., Park, J.D., Choi, B.S., Chung, Y.H., Kwon, I.H., Jeong, J., Han, B.S., Shin, J.H., Sung, J.H., Song, K.S. and Yu, I.J. (2007), Twenty eight day inhalation toxicity study of silver nanoparticles in Sprague Dawley Rats, Inhalation Toxicology, 19 (10), 857-871. https://doi.org/10.1080/08958370701432108
  6. Jung, J.H., Oh, H.C., Noh, H.S., Ji, J.H., Kim, S.S. (2006), Metal nanoparticle generation using a small ceramic heater with a local heating area, J. Aerosol Sci. 2006;37:1662-1670. https://doi.org/10.1016/j.jaerosci.2006.09.002
  7. Lux Research, (2007), The nanotech report. 5th ed. New York: Lux Research.
  8. Mahdavi A., Haghighat F., Bahloul A., Brochot, C. and Ostiguy, C. (2015), Particle Loading Time and Humidity Effects on the Efficiency of an N95 Filtering Facepiece Respirator Model under Constant and Inhalation Cyclic Flows. Ann. Occup. Hyg. 59(5), 1-12
  9. NIOSH, (2009), Approaches to Safe Nanotechnology : Managing the Health and Safety Concerns Associated with Engineered Nanomaterials.
  10. Zhou, Y. and Cheng, Y.S. (2016), Evaluation of N95 Filtering Facepiece Respirators Challenged with Engineered Nanoparticles, Aerosol and Air Quality Research, 16, 212-220.